Rio PROLIFT User manual

user guide
PROLIFT
™

PRECAUTIONS
• Pleasereadallinstructionsthoroughlyandretainforfuturereference.
• WedoNOTrecommendPROLIFTtobeusedbypeoplewhoare:pregnant,haveapacemaker,sufferfromhigh
orlowbloodpressure,epilepsy,heartproblems,diabetes,multiplesclerosis,skinrelatedillnesses,underthe
influenceofalcoholorrecoveringfromrecentsurgery.
• DoNOTuseonareasofskinwithdisorderssuchasrosacea,pustularacne,abradedskin,sensitiveskin,orover
scars,molesorvaricoseveins.
• This device should NOT be used in the following cases: benign and malignant tumours, haemorrhages,
inflammationsoftheskin,openandfreshwounds,bruisesorbrokenskin.
• Stopuseandconsultyourdoctorifyouexperiencediscomfortduringuse.
• DoNOTputthepadsoveranyconductivebodyjewellery.
• DoNOTsticktheelectrodestoeachother.DoNOTtouchthepadswithhands.
• DoNOTusewhilebathingorinashower.DoNOTusewhiledriving.
• Keepoutofreachofchildrenandpets.
• NOTfortheuseonchildrenundertheageof14,ahelplesspersonoronananimal.
• Thisapplianceisnotintendedforusebypersonswithreducedphysical,sensoryormentalcapabilities,orlackof
experienceandknowledge,unlesstheyhavebeengivensupervisionorinstructionconcerninguseoftheappliance
byapersonresponsiblefortheirsafety.
• WerecommendusingthePROLIFTforamaximumof20minutesintotalpersession,with24hoursbetween
sessions.

1
INTRODUCTION
UsinggentleElectricalMuscleStimulation(EMS)PROLIFThelpslift,
firmandtonetargetedareasoftheface.
™
PROLIFT
1-IN-TFAC2-UK/2.0

2
FARADICFACIALTONING
Practisedforover40yearsinbeautysalons,faradicfacialtoningusesEMS(Electrical-MuscleStimulation)toactivate
thenerveswhichcontrolthefacialmuscles.Thepulsesgentlycontractandrelaxthefacialmusclestohelptone,lift
andtighten.Thepulsesgeneratedmimicnaturalnervesignalstoexercisethefacialmuscles.Thetargetedmuscles
areshownbelow.
ORBICULARIS OCULI
Closestheeyelids.
NASALIS
Movesthenostrils.
ZYGOMATICUS MINOR andZYGOMATICUS MAJOR and
LEVATOR LABII SUPERIOR
Worktogethertocontroltheupperlip
ORBICULARIS ORIS
Puckersthelips.
PLATYSMA
Drawslowerlipdownward
andtotheside
DEPRESSOR ANGULI ORISand
DEPRESSOR LABII INFERIORIS
Affectsfacialexpressionbyeffectingtiny
movementsaroundthelowerlipandmouth.
MENTALIS
Liftsandwrinklesskinofchinandprotrudeslowerlip.
MASSETER
Workstoopenandclosethemouth.
FRONTALIS
Raiseseyebrows.

3
PROLIFTCONTENTS
L R
M
L R
M
1Hands-freeadjustableheadset
2Controlunit
3Reusablegelpads
43xAAAbatteries
5Beautycase
1
2
3
45

4
KNOWYOURPROLIFT
L R
M
1Headset
2Gelpadlocation
3Connectorcable
1
2
HEADSET
3
CONTROL UNIT
4Controlunit
5Programmelights(1-4)
6Intensityincrease(Left&Right)
7Mode/progammebutton
8Intensitydecrease(Left&Right)
9Poweron/offbutton
0Connectorsocket
!3xAAAbatteries
L R
M
BACKVIEW
40
7
9!
5
1234
6
8

5
BATTERYINFORMATION
Release the clip and open the
batterycover.
Insert three AAA batteries ensuring
thepolarityisasshown.
NOTE: Thebattery fitis looseuntil
thebatterycoverisreplaced.
Replacethecoverensuringitisshut
firmlyinplace.
LOWBATTERYINDICATION
Whenthebatteriesarerunninglow,
light 4 will flash when the unit is
turnedon.
NOTE: The unit will power off after
5seconds.
• If the unit is left unused for a long period of time,
removethebatteries.
• DoNOTuserechargeablebatteries.
• Please ensure that the batteries are disposed of in
thecorrectmannerinaccordancewithlocalauthority
requirements.
L R
M
1
2
3

6
IMPORTANT-PATCHTEST
Beforefirstusedoapatchtestwithagelpadtotestforpossibleskinreaction.Placeagelpadonaninconspicuous
areae.g.insideyourforearmandleaveinplacefor20minutes.Wait24hours.IfirritationoccursDONOTcontinue
treatment.
ATTACHINGTHEGELPADS
Start by removing the white plastic
protectivebacking.
DO NOTremovetheclearprotective
film.
Positionthegelpadsovertheblack
conductive areas, press into place
ensuring they fully cover the black
conductiveareas.
Nowpeelofftheclearpadprotector
ensuring that you retain and
replace after use. We recommend
moistening the gel pads with a
damp tissue before each use.
Connect the headset to the control
unit.
Tieanyloosehairbackfromtheface
andwashanddrytheskinwherethe
padsaretobeplaced.
GETTINGSTARTED
5
4
1
2
3

7
POSITIONINGTHEHEADSET
ProLiftshouldbeusedwhilstsittinginarelaxedposition.
The unit should remain turned off until the headset is
positioned correctly on the face.
Start by holding the headset
behind the neck with the cable
onyourlefthandside.
TIP:Youmayfinditusefultouse
amirrortoseethepositioning.
Slowlybringtheheadsetbelow
theears and then forward over
thejawline.
Placethegelpadsjustunderthecheekbonesinlinewith
thebaseofyournoseandthemiddleofyourears.
TIP: The pressure can be
reduced by extending the
headband.
1
2
3

8
INCORRECTPOSITIONING
DO NOT overstretch or pull
the headset down over the
head, as this will put undue
stressontheheadset.
DO NOTplacethegelpads
abovethecheekbonesortoo
closetotheear.
DO NOTplacethegelpads
onthetemplesoracrossthe
throat.
DO NOThavethecableon
yourrightside.Theheadset
is upside down in this
position.
X
X
POSITIONINGTHEHEADSET
X
X

9
INSTRUCTIONS
Insert headset cable into control
unit. Important: Do not remove or
insertthecablewhiletheunitison.
Turn on by pressing the on/off
button,light1willflash.
NOTE:Ifnotinuse,theunitwillenter
stand by mode and automatically
turnoffafter20minutes.
Press the " M " button to select
your required programme (see
ProgrammeSelection).
Increase the intensity level by
separately pressing both the left
(L) and right (R) "+" buttons, until
you feel a tingling sensation. You
may need to adjust the gel pad
positioning slightly to find the best
contactpoint.
TIP: There are 40 intensity levels in total and the
programmelightwillflashonceeachtimetheintensityis
changed. When on maximum intensity, the programme
lightwillremainilluminated.
Selectalevelwhichiscomfortable.
To decrease the intensity simply
pressthe"-"button.
L R
M
1
L R
M
4
L R
M
2
L R
M
3

10
L R
M
5
L R
M
6
INSTRUCTIONS
MUSCLE STIMULATION
It is normal for muscle strength to differ on each
sideoftheface.Youmayfeelthestimulationmore
intenselyontheleftorrightside.However,ifthereis
a significant difference in intensity, or low intensity,
trythefollowing:
1.Moistengelpadswithasmall amount of water.
2.Ensureskiniscleanandfreshly washed.
3.Replacegelpads.
To change programme press
the"M"button.
NOTE: the intensity level will
reset to level 1 each time you
changeprogramme.
To turn the unit off press the
ON/OFF button. After use
replacethetransparent plastic
gelpadbackings.
NOTE: always switch off the
unitbefore removing thehead
set.

11
HINTS&TIPS
• Werecommendstartingonalowintensityleveluntil
yougetusedtothesensation,thenbuildingupuntil
musclecontractionsarefelt.Beforeyoufeelmuscle
contractionsyoumayfeelamildtinglingsensation.
• Someusersmay feelmuscle contractions atlower
intensitylevelsandsomeathigherintensitylevels-
thisisentirelyanindividualresponse.
• Yourteethmayfeelslightlysensitiveduringtreatment,
thisisperfectlynormal.Forcomfortitisadvisedthat
youtrynottoclenchyourteethwhenusingtheunit.
• For best results we recommend using the ProLift
for 20 minutes every day for the first few weeks,
alternating between the different programmes each
day. There afterward, use as required to maintain
goodtone.
• Asabeginneryoushouldalwaysusetheprogramme
andintensitythatfeelscomfortable.Bestresultsare
achievedbyvaryingtheprogrammesused.
• Leaveaperiodof24hoursbetweeneachtreatment.
• IfyouhavehadBotoxinthelast3months,theeffects
ofusingProLiftwillbereduced.
• Only switch ProLift on when positioned comfortably
ontheface.Turnoffbeforeremoving.
• WhilstusingProLift,ifyoufeelanytwitchingaround
theeyeareaorotherdiscomfort,takeashortbreak
andrepositionthepadsslightly.
• If you feel the muscles twitching after a session
using ProLift, reduce the intensity during your next
treatment. It is recommended to start on a low
setting and build up intensity as your muscles are
strengthened.

12
PROGRAMME 1
LIFT & SCULPT
1 light illuminated
When the "M" mode/programme
button is pressed for the first time,
thisprogrammeisselected.
Rhythmic muscle toning lifts and
tightensfacialmuscles.
PROGRAMME 2
FIRM & REJUVENATE
2 lights illuminated
Varying intensity pulses target
facial muscles giving a deep facial
workout.
PROGRAMME 3
SHIATSU MASSAGE
3 lights illuminated
Arelaxingandgentlepulsingfacial
massage.Idealfor beginners oras
arelaxingwarmuporwinddownto
yourProLiftroutine.
PROGRAMME 4
MAINTAIN
4 lights illuminated
Tobe introducedafter muscletone
has been built up. Maintain is a
combinationofModes1-3.
L R
ML R
M
L R
M
L R
M
PROGRAMMESELECTION
Toselectorchangetheprogramme,pressthe"M"mode/programmebutton.Eachtimethe"M"buttonispressedthe
nextprogrammewillbeselected.
NOTE:
• Eachprogrammewillrunfor10minutesbeforegoing
tostandbymode.Whenre-activatedtheunitwillreset
tolevel1.
• With every change to the programme the unit will
reverttothelowestintensitylevel.

13
NOPULSE
• Dry gel pads-Moistengelpadswithasmallamount
ofwater.
• No battery installed-Insertbatteries.
• Wrong battery polarity - Follow the instructions on
page5.
• Low battery-Replacewithnewbatteries.
• Circuit not working properly-Removebatteriesfor
1minute.Thenreplacebatteriesandtryunitagain.
LIGHT4FLASHESAND
UNITTURNSOFF
• Low battery-Replacebatteries.
WEAKPULSE
• Dry gel pads-Moistengelpadswithasmallamount
ofwater.
• Low intensity-Increasebypressingthe"+"buttons.
• Low battery-Replacebatteries.
• Aged gel pads-Replacethegelpads.
REDSKINAREAAFTERUSE
• Over use-Reducedurationand/orfrequencyofuse.
• Damaged or dried pad-Dampenthegelpadwitha
verysmallamountofwater.Ifthisdoesnotworkreplace
gelpads.
LOOSEATTACHMENTOFTHEPADS
• The pads are worn/damaged-Replacepads.
TROUBLESHOOTING

14
UNITMAINTENANCE
GENERALINFORMATION
• Keepthe transparent plasticgel padbackings and
alwaysreplaceafteruse.
• Avoidtouchingthegelsideofthegelpadswithyour
fingers as this will reduce the adhesiveness of the
surface.
• Youcanprolongthelifeoftheadhesivesurfaceofthe
padsbyapplyingasmallamountofwatertothegel
pads.
• Gelpadslastforapproximatelysevenuses.
• If the unit is left unused for a long period of time,
removethebatteriestoprolongtheirlife.
• Do NOT dissemble or repair. There are no user
serviceable parts inside the unit. If you have any
problemsusing the product, contact ourCustomer
CareDepartment.
• StoreyourProLiftsafelywhilenotinuse.
• Theunitmaybecleanedbywipingwitha
dampcloth.DoNOTusesolventsordetergents.
• DoNOTimmersetheunitinwater.
• Iftheunitisdamageddonotuseit.
• DoNOTuseneartoshortwaveormicrowave
equipment.

15
SPECIFICATION
Powersupply:3xAAA,1.5V,LR03,MN2400
CurrentConsumption:110mA
BatteryLife:7hrs

16
DISPOSAL
TheWasteofElectricalandElectronic Equipment (WEEE) Directive(2002/96/EC)hasbeenputinplace
torecycleproductsusingbestavailablerecoveryandrecyclingtechniquestominimisetheimpactonthe
environment,treatanyhazardoussubstancesandavoidtheincreasinglandfill.
TheproductisclassedasElectricalorElectronicequipmentsopleaseensureattheendofthelifeofthisproductand
itstreatmentcartridgetheyaredisposedofinthecorrectmannerinaccordancewithlocalauthorityrequirements.
TheymustNOTbedisposedofwithhouseholdwaste.
CUSTOMERCARE
Ifyouhaveanyquestions,orifyouexperienceanydifficultieswiththis product, please call our Rio Carelineon:
01242702345oremailusat:[email protected]
Toregisteryourtwoyearguaranteeonlinevisit:www.riobeauty.com/warranty_online.htm

17

www.riobeauty.com
Rio,DezacandProLiftaretrademarksofTheDezacGroupLtd©TheDezacGroupLtd2013
ManufacturedbyTheDezacGroupLtd,POBox17,Cheltenham,EnglandGL537ET
1-IN-TFAC2-UK/2.0
UK
This manual suits for next models
1
Table of contents
Other Rio Personal Care Product manuals

Rio
Rio HYDRA-MASQUE User manual

Rio
Rio 60 SECOND FACE TONER User manual

Rio
Rio handLITE User manual

Rio
Rio 5019487085757 User manual

Rio
Rio Total Body Waxing User manual

Rio
Rio NAPE User manual

Rio
Rio PORE PERFECTION WIRELESS User manual

Rio
Rio faceLITE User manual

Rio
Rio RAPID HEEL SMOOTHER User manual

Rio
Rio SKIN RENEW MICRODERMABRASION Drma3 User manual
Popular Personal Care Product manuals by other brands

Skytrofa
Skytrofa Auto-Injector Instructions for use

HAPRO
HAPRO Seecret C25 Original instructions

Panasonic
Panasonic EW1611 operating instructions

WJT ORTHO
WJT ORTHO HOS user manual

BioIntelliSense
BioIntelliSense BioButton BIOST03020 Instructions for use

Clarisonic
Clarisonic PRO SONIC SKIN CLEANSING user guide