Alltensioningwillbeperformedfromtheconicaltensioningthreadendofthestudwith
orientationofthestudtotheflangeasshowninFigures1&2.
8.1AssemblyofTensionerKitwithORANGESafetyGuard
RefertoTensionerdrawingandFigure4fortensionertoflangemounting.Assemblysequenceisas
follows:
1. Carefullycheckthecleanlinessofboththestud'sandthepullerscrew'sconicalthreads.
2. Ensurestudlengthmeasurementisdocumented.
3. Verifystickoutlengthofstudtonut.
4. Applyalightcoatofcleanturbineoiloraspraylubricanttothepullerscrew.Donotuse
“NeverSeize”ontheconicalthreads.
5. Placethespannerringontothenut
6. Installonepullerscrewreleasetapestripintoendofstud.(AppendixB2)
7. Insertthepullerscrewintothetaperedthreadofthestudandhandtighten.Besurenotto
cross‐threadtheassembly
8. UsinganAllenwrenchtightenpullerscrew,thenbackoffpullerscrew1/2aturn.
9. Retightenpullerscrewbyhanduntilitisfullyinserted.DONOTBACKOFFPULLERSCREW.
10. Placethefootoverpullerscrew,orientateintoposition.
11. Threadtensionerontopullerscrew.Note:Internalstopintensionerwillresultingapwith
foot.DONOTTIGHTENTENSIONERAGAINSTFOOT.(GAPSHOULDBE1/16”to3/16”)
12. Placeguardovertensionerandpositionguidepinintohexendofstud.
13. Tightenknurledinterlockfittingbyhanduntilitfirmlypressesagainsttensioner.(nogap)
14. Activatecustomconnectorfromrearofguardbypushingonthecenterwithyourthumband
pullingthetabswithyourforefingerandmiddlefinger.Pushtheassemblyforwarduntilit
locksontothetensioner.Releasefingersfromtabsandthenremovethumb.Ensure
connectionisfirmlyengagedorelsethetensionerwillnotbeconnectedtopump.