logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Roca
  6. •
  7. Bathroom Fixture
  8. •
  9. Roca D50010008 User manual

Roca D50010008 User manual

Other Roca Bathroom Fixture manuals

Roca SENTRONIC A890092200 User manual

Roca

Roca SENTRONIC A890092200 User manual

Roca NEOS III User manual

Roca

Roca NEOS III User manual

Roca GRANADA A276261000 User manual

Roca

Roca GRANADA A276261000 User manual

Roca A5A104AC00 User manual

Roca

Roca A5A104AC00 User manual

Roca DEBBA COMPACT 855900 Series User manual

Roca

Roca DEBBA COMPACT 855900 Series User manual

Roca HOTEL'S A815508 User manual

Roca

Roca HOTEL'S A815508 User manual

Roca Multiclin Premium RF User manual

Roca

Roca Multiclin Premium RF User manual

Roca SENTRONIC-S A5A8102C00 User manual

Roca

Roca SENTRONIC-S A5A8102C00 User manual

Roca DEBBA 856826 Series User manual

Roca

Roca DEBBA 856826 Series User manual

Roca ETERNAL A5A978B 0 Series User manual

Roca

Roca ETERNAL A5A978B 0 Series User manual

Roca 857001402 User manual

Roca

Roca 857001402 User manual

Roca L20-E User manual

Roca

Roca L20-E User manual

Roca Danube T D50010004 User manual

Roca

Roca Danube T D50010004 User manual

Popular Bathroom Fixture manuals by other brands

DURAVIT C.1 C15240 0090 Instructions for mounting and use

DURAVIT

DURAVIT C.1 C15240 0090 Instructions for mounting and use

Sunshower PURE SOLO manual

Sunshower

Sunshower PURE SOLO manual

Heatstore HSTRL500WTN Installation and operating instructions

Heatstore

Heatstore HSTRL500WTN Installation and operating instructions

Delabie Delabie Sporting 714700 manual

Delabie

Delabie Delabie Sporting 714700 manual

Kohler K-13056 Homeowner's guide

Kohler

Kohler K-13056 Homeowner's guide

ESS Container TCL-11 installation manual

ESS

ESS Container TCL-11 installation manual

Mustee 22C installation instructions

Mustee

Mustee 22C installation instructions

VITRA V-Flow manual

VITRA

VITRA V-Flow manual

Malmet B105BT Operation, maintenance and installation manual

Malmet

Malmet B105BT Operation, maintenance and installation manual

bathstore Transition H1690MM Installation, Care & Adjustment Instructions

bathstore

bathstore Transition H1690MM Installation, Care & Adjustment Instructions

baliv DUK-80.30 T manual

baliv

baliv DUK-80.30 T manual

baliv DU-5160 manual

baliv

baliv DU-5160 manual

BELLOSTA Edward 0800/M Installation instruction

BELLOSTA

BELLOSTA Edward 0800/M Installation instruction

Franke PRTR0006 Installation and operating instructions

Franke

Franke PRTR0006 Installation and operating instructions

Gessi RILIEVO 59011 manual

Gessi

Gessi RILIEVO 59011 manual

noken VITAE 100188525-N299998810 manual

noken

noken VITAE 100188525-N299998810 manual

Allen + Roth 1142VA-30-201 manual

Allen + Roth

Allen + Roth 1142VA-30-201 manual

Britex HBDA installation guide

Britex

Britex HBDA installation guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Maxiflow Overflow Bath Filler And Waste
D50010008
Installation And Operating Instructions
Inlet Connections:
1½"
Features:
Technical Specification
Working Pressure:
Min:
Max:
Operating Temperature:
Hot:
Cold:
0.5 Bar
5.0 Bar
70⁰C
5⁰C
WWaarrrraannttyy IInnffoorrmmaattiioonn
Proof of purchase will be required.
The guarantee does not cover faults or damage caused by incorrect
installation and/or maintenance, ordinary wear and tear, water
composition, etc.
*Please see www.uk.roca.com for full terms and conditions of warranty
CClleeaanniinngg
Your product has a high-quality finish and should be treated with care
to preserve the visible surfaces. Never use abrasives or abrasive
cleaning agents to clean this product clean regularly with
contamination free warm water and a damp soft cloth. Do not use
products containing chlorine bleach or hydrochloric acid as these can
damage the product.
We have a policy of continuous improvement and reserve the right to
change specifications without notice.
ROCA
Customer Care Line
TEL: 01530 830080
INST D50010008
29/04/2021
•Operated by over flow allowing hands free
drainage
P2 P7
C
C
o
o
n
n
t
t
e
e
n
n
t
t
s
s
Congratulations on your purchase of your NEW Maxiflow Overflow Bath
Filler And Waste.
Our fitting instructions have been created with you in mind to provide
you with all the information you require and, if you need any further
help, please don't hesitate to contact our customer care team on 01530
830080
P
P
L
L
E
E
A
A
S
S
E
E
R
R
E
E
T
T
A
A
I
I
N
N
T
T
H
H
I
I
S
S
D
D
O
O
C
C
U
U
M
M
E
E
N
N
T
T
F
F
O
O
R
R
F
F
U
U
T
T
U
U
R
R
E
E
R
R
E
E
F
F
E
E
R
R
E
E
N
N
C
C
E
E
I
I
M
M
P
P
O
O
R
R
T
T
A
A
N
N
T
T
:
:
Please read all of the instructions before installation.
Roca recommends this product is installed by a competent person in
compliance with all relevant regional regulations.
Remove all packaging and check the components for damage before starting
installation.
This product must not be modified in any way as this will invalidate the
guarantee.
It is the responsibility of the installer to ensure a waterproof seal is achieved,
after installation all connections must be checked for leaks.
All outlets used primarily for personal hygiene shall deliver water at a safe
temperature as per regional regulations.
Before commencing installation of the new product, ensure that the system
has been flushed to remove any debris, which could cause damage to the
valves and invalidate the warranty.
L
>1,5°1,5°
P6 P3
L
L
i
i
n
n
e
e
D
D
r
r
a
a
w
w
i
i
n
n
g
g
<6mm
L+ 30mm
Ø40
mmØ40mm
OPTIONAL
Ø40
mm
9, Fit the waste body and flange to the bath securing using screw and washer; ensure sealing
washer is placed through the bath before this is done as shown on diagram. Use a pure
Silicon sealant where necessary.
9, Cut any excess tube and fit into waste body using washer and nut
provided.
58
G 1” 1/2
L
G 1/2”
42.5
P4
P5
I
I
n
n
s
s
t
t
a
a
l
l
l
l
a
a
t
t
i
i
o
o
n
n
o
o
f
f
o
o
v
v
e
e
r
r
f
f
l
l
o
o
w
w
1, Connect flexible tube to outlet. 2, Connect flexible connector to elbows.
3, Fit the overflow waste body to the
bath ensuring overflow washer is in
place.
4, Turn the filter retaining nut
clockwise, to secure in place.
4 Nm
max 5 Nm
5, Tighten the nut to 4Nm
6, Fasten the .. to the rear of the handle,
tight and secure into place with allen key.
7, Place handle and fixing through the
hole in overflow waste body.
8, Click into place
P4 P5
IInnssttaallllaattiioonn ooff oovveerrffllooww
1, Connect flexible tube to outlet. 2, Connect flexible connector to elbows.
3, Fit the overflow waste body to the
bath ensuring overflow washer is in
place.
4, Turn the filter retaining nut
clockwise, to secure in place.
4 Nm
max 5 Nm
5, Tighten the nut to 4Nm
6, Fasten the .. to the rear of the handle,
tight and secure into place with allen key.
7, Place handle and fixing through the
hole in overflow waste body.
8, Click into place
P6
P3
LLiinnee DDrraawwiinngg
<6mm
L+ 30mm
Ø40
mmØ40mm
OPTIONAL
Ø40
mm
9, Fit the waste body and flange to the bath securing using screw and washer; ensure sealing
washer is placed through the bath before this is done as shown on diagram. Use a pure
Silicon sealant where necessary.
9, Cut any excess tube and fit into waste body using washer and nut
provided.
P2 P7
CCoonntteennttss
Congratulations on your purchase of your NEW Maxiflow Overflow Bath
Filler And Waste.
Our fitting instructions have been created with you in mind to provide
you with all the information you require and, if you need any further
help, please don't hesitate to contact our customer care team on 01530
830080
PPLLEEAASSEE RREETTAAIINN TTHHIISS DDOOCCUUMMEENNTT FFOORR FFUUTTUURREE RREEFFEERREENNCCEE
IIMMPPOORRTTAANNTT:: Please read all of the instructions before installation.
Roca recommends this product is installed by a competent person in
compliance with all relevant regional regulations.
Remove all packaging and check the components for damage before starting
installation.
This product must not be modified in any way as this will invalidate the
guarantee.
It is the responsibility of the installer to ensure a waterproof seal is achieved,
after installation all connections must be checked for leaks.
All outlets used primarily for personal hygiene shall deliver water at a safe
temperature as per regional regulations.
Before commencing installation of the new product, ensure that the system
has been flushed to remove any debris, which could cause damage to the
valves and invalidate the warranty.
L
>1,5°1,5°
Maxiflow Overflow Bath Filler And Waste
D50010008
Installation And Operating Instructions
Inlet Connections:
1½"
Features:
Technical Specification
Working Pressure:
Min:
Max:
Operating Temperature:
Hot:
Cold:
0.5 Bar
5.0 Bar
70⁰C
5⁰C
W
W
a
a
r
r
r
r
a
a
n
n
t
t
y
y
I
I
n
n
f
f
o
o
r
r
m
m
a
a
t
t
i
i
o
o
n
n
Proof of purchase will be required.
The guarantee does not cover faults or damage caused by incorrect
installation and/or maintenance, ordinary wear and tear, water
composition, etc.
*Please see www.uk.roca.com for full terms and conditions of warranty
C
C
l
l
e
e
a
a
n
n
i
i
n
n
g
g
Your product has a high-quality finish and should be treated with care
to preserve the visible surfaces. Never use abrasives or abrasive
cleaning agents to clean this product clean regularly with
contamination free warm water and a damp soft cloth. Do not use
products containing chlorine bleach or hydrochloric acid as these can
damage the product.
We have a policy of continuous improvement and reserve the right to
change specifications without notice.
ROCA
Customer Care Line
TEL: 01530 830080
INST D50010008
29/04/2021
•Operated by over flow allowing hands free
drainage