2100 SERIES ELECTRONIC DIGITAL METER
METRO DE DIGITAL ELECTRÓNICO DE 2100 SERIES
MULTIMÈTRE NUMÉRIQUE ÉLECTRONIQUE DE 2100 SÉRIES
Parts and Technical Service guide
Guía de servicio técnico y recambio
Guide d’instructions et pièces de rechange
Ref.: 2100 SERIES
METER/HANDLE
Oval Gear hose end meter/ handle or bare meter with
electronic display for lubricants and anti-freeze. It is
currently available for Pints, Quarts and Litres and a
variety of outlet configurations for different service
applications. A large capacity inlet screen located
inside the swivel inlet protects the Valve and Oval
Gears. Accuracy ± 1% unadjusted.
Metro oval/manija del extremo de la manguera del
engranaje o metro pelado con la visualización
electrónica para los lubricantes y el anticongelante.
Es actualmente disponible para las pintas, los cuartos
de galón y los litros y una variedad de
configuraciones del enchufe para diversos usos del
servicio. Una pantalla grande de la entrada de la
capacidad situada dentro de la entrada del eslabón
giratorio protege la válvula y los engranajes ovales.
5% del ± de la exactitud sin ajustar.
Mètre ovale d'extrémité de tuyau de vitesse/poignée ou mètre nu avec la visualisation électronique pour les
lubrifiants et l'antigel. Elle est actuellement disponible pour des pintes, des litres et des litres et une variété de
configurations de sortie pour différentes applications de service. Un grand écran d'admission de capacité situé
à l'intérieur de l'admission de pivot protège la valve et les vitesses ovales. 5% de ± d'exactitude non ajusté.
• Attach the meter/handle using the provided ½” threads. Seal the threads with Loctite® blue #242
(provided). Allow all of the air to bleed from the (previously flushed) system. Press the reset button on
the face of the meter to return the counter to zero.
Please do not calibrate the meter, as it is not
necessary.
• Instale el meter/handle usando los hilos de rosca proporcionados del ½”. Selle los hilos de rosca con
Loctite® #242 azul (proporcionado). Permita que todo el aire sangre del sistema. Presione para
reajustar el botón en la cara del metro para volver opuestamente a cero
. No calibre por favor el metro,
pues no es necesario.

 Installez le meter/handle en utilisant les fils fournis de ½". Scellez les fils avec Loctite® #242 bleu
(fourni). Permettez à tout l'air de saigner du système. Serrez pour remettre à zéro le bouton sur le visage
du mètre pour renvoyer à l'opposé de zéro
. Veuillez ne pas calibrer le mètre, car il n'est pas nécessaire.
2100 1
F
F
S
Installatio
n
-
O
p
eratio
n
/
Instalación
–
Modo de em
p
leo
/
Installatio
n
–
Mod
e
d
’
em
p
lo
i
E
S
E
Descri
p
tio
n
/
Descri
p
ción
/
D
escri
p
tio
n
Samson Corporation-Swannanoa, NC 28778 800-311-1047 www.samsoncorporation.com
Samson Corporation-Swannanoa, NC 28778 800-311-1047 www.samsoncorporation.com
Re
p
air Kits
/
Kits de Re
p
aracio
n
Part. No. Description Descripción Drawing Include pos.
736625 Handle Assembly Montaje Maneta Figure A Figure A Complete
2100
2101
2102
Meter Assembly Quarts
Meter Assembly Liters
Meter Assembly Pints
Cuartos de galón Metro
Litros Metro
Pintas Metro
Figure B Figure B Complete
Figure B Complete
Figure B Complete
Parts available separately/ Piezas disponibles por separado
1127 Swivel Eslabón Giratorio Figure A 3,7, 12
736102 Trigger Disparador Figure A 2
1137 Manual Drip Tip Extremidad Manual Figure C 18
1138 Semi Auto Drip Tip Extremidad Semi Auto Figure C 19
CH-M1 Handle Kit Montaje Maneta Figure A 9,12,2x13, Swivel
O-Ring(Not Shown)
T
echnical data
/
Datos técnico
s
Maximum Fluid Pressure Presión de fluido máxima 70 bar (1000 psi)
Minimum Flow Flujo Mínimo 1 l/min (¼GPM)
Maximum Flow Flujo Máximo 25 l/min (6.25GPM)
Accuracy Exactitud ± 1% unadjusted
T
roubleshootin
g
/
Anomalías
y
sus solucione
s
Symptoms Possible Reasons Solutions
Flow outside acceptable range. Clean Screen or adjust flow.The meter is not accurate.
T
he meter has been field calibrated. Reset to factor
y
defaults.
Leaks from threads. Assembly/Mounting with inferior thread
sealing compounds.
Reseal threads with Loctite Blue #242
or equivalent product.
Tip not closed. Shake Outlet to clear oil and Close Tip.The drip-tip leaks.
New Installation - Air can be dissolved
in oil even in thorou
g
hl
y
bled s
y
stems.
Wait two weeks for Air to clear system;
t
hen recheck for leaks.
2100 2

Other Samson Measuring Instrument manuals

Samson 411 110 Operating manual

Samson

Samson 411 110 Operating manual

Samson Media 7 5007-1 Service manual

Samson

Samson Media 7 5007-1 Service manual

Samson 411 120 Operating manual

Samson

Samson 411 120 Operating manual

Samson 024.85 User manual

Samson

Samson 024.85 User manual

Samson Media 05 Service manual

Samson

Samson Media 05 Service manual

Samson Media 6 Z Technical document

Samson

Samson Media 6 Z Technical document

Samson D-150 User manual

Samson

Samson D-150 User manual

Samson Media 6 Service manual

Samson

Samson Media 6 Service manual

Samson 2100 Series Troubleshooting guide

Samson

Samson 2100 Series Troubleshooting guide

Samson Media 6 Service manual

Samson

Samson Media 6 Service manual

Samson 1100 SERIES User manual

Samson

Samson 1100 SERIES User manual

Samson Media 6 User manual

Samson

Samson Media 6 User manual

Samson Media 7 Service manual

Samson

Samson Media 7 Service manual

Popular Measuring Instrument manuals by other brands

SENKO SI-100IM user manual

SENKO

SENKO SI-100IM user manual

Matrix MCR5000 Series user manual

Matrix

Matrix MCR5000 Series user manual

AEG AEGLDM100 Original instructions

AEG

AEG AEGLDM100 Original instructions

Endress+Hauser Micropilot S FMR540 manual

Endress+Hauser

Endress+Hauser Micropilot S FMR540 manual

Elcometer 345 operating instructions

Elcometer

Elcometer 345 operating instructions

Hanna Instruments HI 749 instruction manual

Hanna Instruments

Hanna Instruments HI 749 instruction manual

pyroscience FireStingO2 user manual

pyroscience

pyroscience FireStingO2 user manual

Tohnichi M-DW manual

Tohnichi

Tohnichi M-DW manual

Fluke 345 Calibration manual

Fluke

Fluke 345 Calibration manual

Seaward HALO II operating instructions

Seaward

Seaward HALO II operating instructions

Inficon Pilot Plus operating manual

Inficon

Inficon Pilot Plus operating manual

PASCO Pasport PS-2600 reference guide

PASCO

PASCO Pasport PS-2600 reference guide

Starr Instruments TGD-100 instructions

Starr Instruments

Starr Instruments TGD-100 instructions

Vaisala CL31 user guide

Vaisala

Vaisala CL31 user guide

ADA INSTRUMENTS Robot Mini operating manual

ADA INSTRUMENTS

ADA INSTRUMENTS Robot Mini operating manual

Belter ePA-46B user manual

Belter

Belter ePA-46B user manual

Exxentric kMeter II quick start guide

Exxentric

Exxentric kMeter II quick start guide

Alentec & Orion 24702 user manual

Alentec & Orion

Alentec & Orion 24702 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.