2100 SERIES ELECTRONIC DIGITAL METER
CONTADOR ELECTRÓNICO SERIE 2100
Technical service guide and spare parts listing
Guía de servicio técnico y recambios
Part Nº/ Cód.:
2100 SERIES
Samson Corporation-Swannanoa, NC 28778-800.311.1047 www.samsoncorporation.com
E
SP
Oval gear type Hose end meter/ In-line meter with electronic LCD display for
Lubricants, Anti-Freeze and WW Fluid. The Hose end meter includes a
progressive opening control valve for precise control of oil delivery, a ball-bearing
inlet swivel with an extra large filter, and an outlet hose with non-drip tip.
Pistol
E
SP
a contadora/ Contador en línea de engranajes ovales y registrador
Install the outlet extension to the outlet thread of the meter and tighten it well (fig 2).
(provided).
. Coloque la extensión a la salida de la pistola y apriete firmemente (Fig. 2).
dora usando sellador.
electrónico para lubricantes y anti-congelante. La pistola contadora incluye una
válvula con apertura progresiva para un mejor control del caudal de suministro,
rótula de entrada con filtro y extensión con boquilla anti-goteo.
1.
2. Thread the dispensing hose to the inlet swivel of the hose end meter using Loctite242
1
2. Rosque la manguera de suministro a la rótula de entrada de la pistola conta
2100 1
Fi
g
. 2
2100
2162
Installation
/
Instalació
n
Descri
p
tion
/
Descri
p
ció
n
E
SP
Samson Corporation-Swannanoa, NC 28778-800.311.1047 www.samsoncorporation.com
E
SP
E
SP
meter is delivered ready for use, and needs no additional attention even after a
ned on, or the “low battery” indication (2) appears in the
he meter has two totalizer registers incorporated; one resettable (4) and another
he reset button (3) must be pressed prior each delivery to clear the partial
ntador está suministrado listo para usar, y no necesita manipulación alguna
baja tensión (2) se muestra en la
contador tiene incorporado dos totalizadores; uno con posibilidad de puesta
ro (3) para inicializar el contador parcial (1).
convenient to change the measuring units in the meter according to the following
l the display
s posible cambiar las unidades de medición del contador según las siguientes combinaciones
alibr” presionados hasta
The
long storage period.
If the display is not tur
display, see Replacing batteries.
T
non-resettable (5). To bring up the resettable total register, press the reset button
(3). If the reset button is pressed again (immediately), the resettable total register
is set to zero. If not, after a few seconds the non-resettable total register will
appear.
NOTE: T
a cero y otro sin esta posibilidad. Para
Fi
g
. 3
reading (1).
El co
aún después de un largo tiempo de almacenaje.
Si la pantalla no está encendida, o el indicador de
pantalla, ver Sustitución de pilas.
El
visualizar la cantidad acumulada en el totalizador con posibilidad de puesta a cero, presionar el botón “Reset” (3). Si se vuelve
a presionar este botón inmediatamente, este totalizador se pone a cero. Sino, después de algunos segundos aparecerá la
cantidad acumulada en el totalizador sin posibilidad de puesta a cero.
ATENCIÓN: Antes de cada servicio, presionar el botón de puesta a ce
It is
combinations (Partial reading – Total register): Gal – Gal, Qts – Gal, Pts – Gal, L – L.
To change the measuring units, press and hold the Reset and the Calibr buttons unti
appears showing ‘Unit’ as in fig. 4. Use the Reset button to change units and press the Calibr
button to confirm.
E
(Registrador parcial – Totalisador): Gal – Gal, Qts – Gal, Pts – Gal, L – L.
Para cambiar las unidades de medición, mantener los botones “Reset” y “C
que la pantalla aparece como en Fig. 4. Utilizar el botón “Reset” para elegir unidades y mantener
el botón “Calibr” para confirmar.
Remove the two screws and the battery cover (1) (Fig.5).
NOTE: Always replace
3. ery cover (1).
the meter display.
1. estornillar y retirar los tornillos y la tapa de las baterías (1) (Fig. 5).
A: Sustituir
3.
der la pantalla.
1.
2. Replace the old batteries with new ones (2xAAA Alkaline).
both batteries at the same time. Confirm that the batteries are placed in their
correct position.
Reattach the batt
4. Press the reset button to turn on
D
2. Sustituir las baterías por nuevas (2xtamaño AAA alcalinas). NOT
siempre las dos pilas a la vez. Asegurar que la posición de las pilas es la correcta.
Volver a montar la tapa de las baterías (1).
4. Presionar el botón puesta a cero para encen
2100 2
Re
p
lacin
g
batteries
/
Sustitución de
p
ila
s
O
p
eration
/
Modo de em
p
le
o
Fi
g
. 4
Measurin
g
units
/
Unidades de medició
n
Fi
g
. 5
Samson Corporation-Swannanoa, NC 28778-800.311.1047 www.samsoncorporation.com
E
SP
is not necessary to separate the meter from the oil control gun to clean the chamber.
measuring
ve the cover at the back of the meter.
he gears carefully using a soft brush.
.
en
ior del contador.
los engranajes cuidadosamente utilizando un cepillo suave.
It
WARNING: Do not open the control valve by pressing the trigger while cleaning the
chamber.
1. Remo
2. Remove the oval gears.
3. Clean the chamber and t
4. Replace the gears, then reattach the cover as shown in figure 6
No es necesario separar el contador de la pistola de control aceite para limpiarlo. ATENCIÓN: T
cuidado de no abrir la pistola de control de aceite presionando el gatillo de forma accidental durante la
limpieza del contador.
1. Retirar la cubierta infer
2. Retirar los engranajes ovales.
3. Limpiar la cámara de medición y
4. Volver a colocar los engranajes, la junta y la tapa inferior como muestra la figura 6.
83681x 2
Fi
g
. 6
Symptom Possible Causes Solution
METER
Faded display Weak batteries Replace the batteries
Dead batteries Replace the batteriesNo reading in the display
t been reset after battery
Display Blank Meter has no
re
p
lacemen
t
Press the reset key
Wrong calibra
Flow rate is outside the wo Increase or decrease
not work
Gears placed incorrectly after cleaning t
measuring chamber
Place the gears in the right position
Clogged inlet screen Clean the inlet screenReduced flow
Obstructed
g
ears Clean the measurin
g
ch
Oil leaking in closed position Contaminated valve seat or damaged valve Clean the valve seat and if necessary,
replace damaged parts
Replace O rings
tion factor Calibrate the meterThe meter is not accurate
rkin
g
flow ran
g
e the flow rate
The display is on but the meter does he
amber
GUN
Oil leaking through trigger cam Damaged O rings
Síntoma Posibles causas Solución
CONTADOR
Lectura borrosa o poco clara Baterías gastadas Cambiar las baterías
Baterías gastadas Cambiar las bateríasEl display no muestra ninguna señal
uesta a cero después de esta a ceroNo se realizó la p
cambiar las baterías
Presionar el botón pu
Factor de calibración
El caudal suministrado está fuera del rango de
caudales
Ajustar el caudal de fluido dentro
ran
g
o de caudales del contador
display esté encendido
Los engra Verifique que los engranajes es
posición
Limpiar elCaudal reducido
Los en
g
rana
j
es están obstruidos Lim
p
iar la cámara de medici
Salida de aceite en posición cerrado Válvula gastada o impurezas en el asiento de Limpiar el asiento de la válvula y sustituir
la válvula las piezas en caso de deterioro
Junta tórica Sustituir la junta tórica
errónea Calibrar el contador correctamenteFallos en la precisión del contador
del
El contador no cuenta aunque el najes están mal colocados tán en la
El filtro de entrada (opcional) está obstruido filtro de entrada
ón
GUN
Fuga de aceite por el eje del gatillo deteriorada
2100 3
Cleanin
g
the measurin
g
chamber
/
Lim
p
iar la cámara de medició
n
T
rouble shootin
g/
Anomalías
y
sus solucione
s
Samson Corporation-Swannanoa, NC 28778-800.311.1047 www.samsoncorporation.com
E
Please do not calibrate the meter, as it is not necessary.
SP
or, no calibrar el contador, ya que no es necesario.
Max. Working Pressure Presión máxima de trabajo 1000PSI / 70 bar
Por fav
Min. Rupture Pressure Presión mínima de rotura 2000 PSI / 140 bar
Delivery range Caudal ¼ - 5 GPM / 1-20 l/min
Max. Pressure drop de cargaPérdida 18 PSI / 1.25 bar
Temperature range Temperatura 32ºF – 40ºC / 0ºC – 40ºC
Max./min. fluid viscosity osidad de fluidoMax./min. visc 5000/5 mPa/s
Accuracy (unadjusted) Precisión (sin ajuste) ± 1 %
Weight Peso 3.5 LBS
/ 1.6 kg
Pos Part Nº Description Descripción Pos Part Nº Description Descripción
1 1127 Swivel Rótula 11 942104 Washer Arandela
2 836302 aSpring Muelle 12 946068 O ring Junta tóric
3 736608 Valve holder lvulaPorta-vá 13 736606 Cam Eje
4 836500 Valve Válvula 14 946083 O ring a tóricaJunt
5 736607 Sleeve Empujador 15 2100 Meter Contador
6 736106 Body Cuerpo 16 8 ection36504 Meter prot Protección
contador
Extensión
8 Screw Tornillo 94601418 O ring Junta tórica
9 Washer Arandela 19 836404 Filter Filtro
10 940 02 ,
ement
bly
je de la1 Screw Tornillo 1-13
18, 19
736625 Replac
Handle Assem
Monta
pistola del
reemplazo
7 736102 Trigger Gatillo 17 1128 Outlet hose
2100 4
S
p
are
p
arts
/
Recambio
s
Technical information
/
Información técnic
a

This manual suits for next models

2

Other Samson Measuring Instrument manuals

Samson Media 6 Z Technical document

Samson

Samson Media 6 Z Technical document

Samson Media 6 Service manual

Samson

Samson Media 6 Service manual

Samson Media 7 5007-1 Service manual

Samson

Samson Media 7 5007-1 Service manual

Samson Media 05 Service manual

Samson

Samson Media 05 Service manual

Samson 411 120 Operating manual

Samson

Samson 411 120 Operating manual

Samson Media 6 User manual

Samson

Samson Media 6 User manual

Samson D-150 User manual

Samson

Samson D-150 User manual

Samson 1100 SERIES User manual

Samson

Samson 1100 SERIES User manual

Samson Media 7 Service manual

Samson

Samson Media 7 Service manual

Samson 024.85 User manual

Samson

Samson 024.85 User manual

Samson Media 6 Service manual

Samson

Samson Media 6 Service manual

Samson 411 110 Operating manual

Samson

Samson 411 110 Operating manual

Samson 2162 Operating manual

Samson

Samson 2162 Operating manual

Popular Measuring Instrument manuals by other brands

SECURECOM SS21-GSM M2 quick start guide

SECURECOM

SECURECOM SS21-GSM M2 quick start guide

Stewart Warner Diesel/Alternator Tachometer 3-3/8” & 5” installation instructions

Stewart Warner

Stewart Warner Diesel/Alternator Tachometer 3-3/8” & 5” installation instructions

IME Nemo 96 HDLe Mounting instructions

IME

IME Nemo 96 HDLe Mounting instructions

Bosch 0 603 663 B03 instructions

Bosch

Bosch 0 603 663 B03 instructions

Zeiss GOM Scan 1 User manual hardware

Zeiss

Zeiss GOM Scan 1 User manual hardware

Insportline 23788 user manual

Insportline

Insportline 23788 user manual

Seametrics WMP Series instructions

Seametrics

Seametrics WMP Series instructions

Eastern Energy 840063 instruction manual

Eastern Energy

Eastern Energy 840063 instruction manual

SENSIT Technologies SENSIT GOLD G2 Quick start instructions

SENSIT Technologies

SENSIT Technologies SENSIT GOLD G2 Quick start instructions

Associated Research HypotULTRA 7800 Operation and service manual

Associated Research

Associated Research HypotULTRA 7800 Operation and service manual

OHAUS Defender T24PE instruction manual

OHAUS

OHAUS Defender T24PE instruction manual

Vox VOX-01 quick start guide

Vox

Vox VOX-01 quick start guide

wtw inoLab pH/Oxi Level 1 operating manual

wtw

wtw inoLab pH/Oxi Level 1 operating manual

Digi DW1A instruction manual

Digi

Digi DW1A instruction manual

PeakTech 5225 Operation manual

PeakTech

PeakTech 5225 Operation manual

Elvaco CMi6140 quick start guide

Elvaco

Elvaco CMi6140 quick start guide

Autel AutoLink AL629 Quick reference guide

Autel

Autel AutoLink AL629 Quick reference guide

ABB MagMaster instruction manual

ABB

ABB MagMaster instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.