Sanctuary SA-PV2M-BIO User manual

IMPORTANT:
Please read this information and follow all safety rules carefully before
operating your gun vault. Failure to do so will void your warranty.
072921
HOME & OFFICE SECURITY VAULTS | INSTRUCTION MANUAL
MODEL: SA-PV2M-BIO

TABLE OF CONTENTS
www.saproducts.com 1
IMPORTANT INFORMATION ............................................................................................... 2
1. REGISTRATION ................................................................................................................ 3
2. UNDERSTANDING YOUR VAULT ...................................................................................... 4
3. INITIAL ENTRY .................................................................................................................. 5
4. BATTERY INSTALLATION................................................................................................... 5
5. PROGRAMMING YOUR FINGERPRINT ............................................................................. 6
6. OPENING VAULT WITH RECORDED FINGERPRINT ...........................................................7
7. PROGRAMMING ADDITIONAL FINGERPRINTS ................................................................ 7
8. TROUBLE SHOOTING ..................................................................................................... 8
9. LOCKOUT OUT MODE/ TAMPER PROTECTION ............................................................... 10
10. CLEARING ALL PROGRAMMED FINGERPRINTS............................................................. 10
11. SILENT ENTRY MODE..................................................................................................... 10
12. PROPER PLACEMENT AND MOVING OF VAULT ........................................................... 11
13. SECURING YOUR VAULT ...............................................................................................11
14. MAINTAINING HINGES AND INTERNAL MECHANISMS .............................................. 13
THREE YEAR WARRANTY ................................................................................................... 14

2
DISCLAIMER - READ BEFORE VAULT SETUP
WEAPON STORAGE
SAFETY
Thank you for choosing a Sanctuary vault to protect your valuables. We are
commied to securing, organizing and protecng your most important documents,
valuables and keepsakes.
If you experience problems or challenges with your vault, please contact us.
Many issues can be quickly resolved without the product being returned.
Be sure to keep backup keys stored in a safe place away from unauthorized users
Do not put anything in your vault that will put pressure against the door when
it is closed.
If you choose to ulize this vault to store a weapon always follow proper weapon and
local laws.
SA Consumer Products strongly recommends that you do not store loaded firearms.
Always follow the firearm safety rules set out by the firearm’s manufacturer.
Store ammunion separately from valuables.
A Sanctuary vault or any other firearm storage device cannot take the place
of other safety procedures including advising children of the dangers of firearms.
SA Consumer Products and its distributors of the Sanctuary vaults do not
recommend, suggest, advise, promote, or otherwise condone the ownership or use of
firearms. We believe the decision to own or use a firearm is a serious decision that
should only be made by an adult who has carefully considered the risks and benefits
of such a decision.
PLEASE READ THIS INFORMATION CAREFULLY BEFORE OPERATING YOUR
SANCTUARY VAULT.
DO NOT LOCK THIS MANUAL OR THE BACKUP ACCESS KEYS IN YOUR VAULT.

3
Register your vault at www.saproducts.com
PURCHASE DATE:
PURCHASE PRICE (BEFORE TAX):
MODEL NUMBER:
SERIAL NUMBER:
KEY NUMBER (IF APPLICABLE):
1. REGISTRATION
RETAILER NAME:
By registering your Sanctuary vault we will be able to expedite and address
any problems or challenges you may have which would otherwise require a
notary leer and proof of payment.
The informaon you record onto this page will be required in the event you
cannot access the contents of your Sanctuary vault. Please fill out all the required
informaon below and retain for your records and safe keeping.
PLEASE HAVE THIS INFORMATION READY PRIOR TO CALLING FOR TECHNICAL
ASSISTANCE AT:
REGISTRATION INFORMATION

Knob
Locking
Bolts
Key
Hooks
Removable
Shelf
Battery
Compartment
Reset Button
(Under Cover)
2. UNDERSTANDING YOUR VAULT
Backup Key Entry
(Under Cover)
Biometric
Scanner
4
Bolt Down Holes
(Under Foam)
Security Cable
Port Entry
Security
Cable

3. INITIAL ENTRY
Step 1
LOCK UNDER
KEY COVER
2.
1. Locate the key cover on the
lockface and remove the
backup key cover carefully by
pulling the key cover tab.
In the future you may place
a flat head screw driver in the
slot and pry upwards.
5
Insert the backup key.
Turn and hold the key
counterclockwise, then
turn the knob on the door
clockwise to grant access
to your vault.
Step 2
4. BATTERY INSTALLATION
Step 1
1.
BATTERY BOX
Locate the (4) AA baeries
and insert in the baery
compartment on the inside
of the door panel as shown.
Keypad will beep (1) me
when baeries are
successfully installed.
Replace the baery cover.
WARNING: The baeries must be inserted with the correct polarity. Exhausted baeries must be
removed from the product and discarded safely. Do not mix old and new baeries. Do not mix
alkaline or standard (carbon – zinc) baeries. Do not use rechargeable (nickel – cadmium) baeries.

6
5. PROGRAMMING YOUR FINGERPRINT
Step 1
1. First, remove the black rubber
plug that covers the reset buon
on the door panel.
2. Use a pen p to press the reset
buon. You will hear 1 beep and
the indicator ring will illuminate
on the front of the door.
NOTE: Recording mode will me out
aer 10 seconds of inacvity. If this
occurs press restart buon and
begin again.
Step 2
BEEP
3. Place and hold the pad of your
finger on the scanner unl it flashes
green and beeps one me.
4. Repeat at least 3 more mes unl
there are 2 consecuve beeps and
2 green flashes.
BEEP
BEEP
BEEP
HOLD FOR BEEP
LIFT FINGER
Step 3Step 4
2 BEEPS + 2 GREEN FLASHES = SUCCESS!
Reset buon located
inside plasc housing

7
6. OPENING VAULT WITH RECORDED FINGERPRINT
If your print is not accepted:
you will see 1 red light flash with 1
sound. This means the scanner did
not read your fingerprint (try again).
If you see 5 red flashes with 5 sounds,
the scanner read your fingerprint but
did not accept it. Follow secon 6 to
reprogram your fingerprint.
x
1
x
1
RED
LIGHT
x
5
x
5
RED
LIGHT
SCANNER LIGHT
TRY AGAIN
REPROGRAM
With keys in hand, close the door.
Place and hold the PROGRAMMED
finger on the scanner, indicator ring
will illuminate green and vault door
will open.
7. PROGRAMMING ADDITIONAL FINGERPRINTS
INDIVIDUALLY MAPPING ALL
ZONES OF YOUR FINGERPRINT
WILL ENSURE A RELIABLE
READING BY THE SCANNER.
To ensure each programming
sequence is properly captured, it
needs to read the exact same place
on your finger four mes in a row,
once successful you can move onto
the next zone of your fingerprint.
This counts as one programmed
fingerprint of 100 fingerprints this
unit can keep in memory.
Once programming sequence has
been successfully completed, you
can move onto the next zone of your
fingerprint.
TIP
RIGHT
TOP
MIDDLE
LEFT
When accessing your vault quickly, there is a chance you might press
the scanner with a part of your finger that you have not registered before.
For this reason, we recommend programming addional areas of your
fingerprint to ensure fast and reliable entry to your vault.

8
7. PROGRAMMING ADDITIONAL FINGERPRINTS
Press the reset buon and follow
Secon 5 instrucons again, for
each fingerprint zone you would
like to program.
If you experience any problems
reading your fingerprint, including
inconsistent readings, note the
area of your fingerprint that
doesn’t work properly, and
specifically re-program that area.
This scanner will hold up to 100
unique fingerprints.
BEEP
BEEP
BEEP
HOLD FOR BEEP
LIFT FINGER
2 BEEPS + GREEN LIGHT = SUCCESS!
8. TROUBLE SHOOTING
Low Battery Indicator
In the event that you run into issues with programming and accessing your
vault, please read through this secon for answers to your quesons.
When opening your vault if the bio scanner illuminates
purple and you hear a long 2 second beep, it means
your vault has entered low baery mode status.
Replace your baeries immediately to avoid being
locked out of your vault.

9
8. TROUBLE SHOOTING (CONTINUED)
Locked Out Of Your Vault
In the event you are locked out your vault, use your backup keys to gain access and
follow the secon 3 Inial Entry instrucons.
If you have lost your backup keys, or are sll having any difficules, contact customer
service at the number below. Proof of purchase is required to obtain keys.
Make sure to hold down your finger on the scanner
instead of tapping, as the scanner needs me to
complete the scanning process.
Fingerprints may lack definion due to excessive
dryness. We recommend applying moisturizer or slide
your fingerprint against your forehead before scanning
process.
Pressing and releasing the reset buon will not erase
fingerprints already recorded. It simply places the
scanner in programming mode to allow for addional
fingerprints to be programmed. This unit will hold up
to 100 unique fingerprints.
YOUR FINGERPRINT
IS NOT READING
WILL PRESSING THE
RESET BUTTON CLEAR
THE MEMORY
Placing a poron of a fingerprint on the scanner that
has not been programmed can result in an error. We
recommend programming mulple areas of each
fingerprint.
Make sure baeries are fresh. We suggest high grade
alkaline. Do not mix old and new baeries. No not use
rechargeable baeries.
Make sure you are placing the same part of your finger
print on the scanner that was used for programming. If
not, make note of the area that is not scanning and
program that area specifically.
SOLUTIONPROBLEM
YOUR PROGRAMMED
FINGERPRINT IS NOT
READING AT ALL TIMES

9. LOCKOUT MODE/ TAMPER PROTECTION
10. CLEARING ALL PROGRAMMED FINGERPRINTS
10
x
2 x
2
GREEN
LIGHT
NOTE: If 100 max fingerprints have already been programmed indicator ring will flash 5
mes and beep 5 mes. We recommend clearing all programmed fingerprints and starng the
programming process over.
Press and hold the reset buon.
Inially, the indicator ring will
flash green and beep once.
Connue holding reset buon
for 5 seconds, the indicator ring
will flash green two mes and
beep two mes.
11. SILENT ENTRY MODE
To iniate silent entry mode, hold a programmed
finger on the scanner for 5 seconds beyond your
fingerprint being accepted. The green indicator
ring will turn off and back on, but will not beep,
indicang you are now in silent entry mode.
You will not hear any sounds for any funcons
while the vault is in silent entry mode.
To turn the sound back on, hold a programmed
finger on the scanner for 5 seconds beyond your
fingerprint being accepted. The green indicator
ring will turn off and back on and will beep once
indicang you are no longer in silent entry mode.
1. Three consecuve incorrect code entries will put
the vault in “Basic Lockout” mode. Scanner is
deacvated for 30 seconds.
2. Aer “Basic Lockout” mode has ended, another
three consecuve incorrect code entries will result
in “Severe Lockout” mode. Scanner is deacvated
for 5-minutes.

11
13. SECURING YOUR VAULT
1.
2.
SECURING YOUR VAULT WITH PROVIDED CABLE
A security cable is included with your
vault. To secure the cable around
a fixed object, first loop the cable
around the object as shown in the
figure to the right.
Insert the cable’s metal peg end into
the hole on the side of the vault
while sll open.
3. From the inside of the vault, take the
cable clip and push it over the metal
peg unl fully secured. Use pliers to
seat the cable clip if needed.
Check the loop to ensure their is no way it can be manipulated to be easily removed
from the fixed object before leaving unaended.
Step 3
12. PROPER PLACEMENT AND MOVING OF VAULT
1.
2.
3.
To maximize burglary protecon and stability, securing the vault to the floor or
table is recommended.
SA Consumer Products recommends that you store your vault in a closet, office,
basement, bedroom or any other locaon that is convenient for you but out of
direct line of sight from prying eyes.
To Always ensure the vault is in an isolated and dry area. Never place the vault in
direct contact with a wet floor. When installing your vault on a concrete floor, use of
a moisture/protecve barrier is highly recommended. Failure to do so or exposing
the vault to chemicals or other adverse environments may void the warranty.
INSIDE OFVAULT,
PUSH CLIPOVER
END OFCABLE
SAFE
INSIDE
CABLE
CLIP
Step 1 & 2

12
13. SECURING YOUR VAULT (CONTINUED)
TOOLS AND HARDWARE NEEDED TO SECURE
VAULT TO A WOOD OR CONCRETE SURFACE:
• DRILL
• 3/8�DRILL BIT
( FOR DRILLING ANCHOR HOLE )
or 3/16� (FOR INSTALL W/ OUT ANCHOR)
• SOCKET WRENCH TO MATCH
BOLT HEAD SIZE
• 2 STEEL LAG BOLTS (NOT INCLUDED) - SIZE 1/4" X 1.50" TO 2.0" LONG
• 2 STEEL WASHERS (NOT INCLUDED) - 1/4"
• 2 PLASTIC ANCHORS (NOT INCLUDED)- SIZE #10-12 X 1.5" TO 1.75" LONG
(FOR CONCRETE INSTALLATION)
• 4 PADS (INCLUDED)
Use the recommended hardware or consult your hardware retailer for fastening
hardware for your parcular mounng surface.
Open the vault door to provide access to the factory drilled bolt down holes that
are located under the protecve foam liner.
To secure your vault to the floor, it will first be necessary to mark and drill pilot
holes in the floor surface.
Drill the appropriate diameter and depth of pilot holes based on the type of
hardware being used and the type of floor surface. When mounng on concrete we
recommend using a drill and a concrete drill bit to drill the two corresponding holes
in the mounng surface.
Secure the vault by threading anchor bolts through the factory drilled bolt down
holes in the vault and screw down ght with a ratchet wrench.
BOLT
WASHER
VAULT
FLOOR
MOUNTING
SURFACE
ANCHOR
FOR CONCRETE
INSTALLATION
14. MAINTAINING HINGES AND INTERNAL MECHANISMS
The hinges and internal locking mechanism are permanently lubricated, thus
needing no maintenance. Opening the door panel of your vault may void your
warranty. Always consult our customer service experts prior to doing so.
WASHERS
(NOT INCLUDED)
PADS
(INCLUDED)
LAG BOLTS
(NOT INCLUDED)
ANCHORS
(NOT INCLUDED)

14
SA Consumer Products will repair or replace, at their sole discreon,
any Sanctuary vault damaged by fire, forced entry, forced aack
or natural flood for the lifeme of the original owner.
SA Consumer Products will repair or replace, at their sole discreon,
any Sanctuary vault with defecve parts, paint or lock for three years
of the original owner purchase date.
If SA Consumer Products deems a replacement vault is to be sent,
they will pay the freight costs to ship the replacement vault to the
original owner.
This three year warranty is limited to the vault and expressly
excludes any loss associated with the contents of the vault.
SA Consumer Products
reserves the right to receive full evidence
of your misfortune, such as a police report and/or homeowner’s
statement of coverage. This warranty is not valid outside of the
United States and Canada.
Proof of registraon and copy of sales receipt must be on file at
the me of claim. Visit our website at www.saproducts.com to
register your vault.
Three year warranty only applies to the original owner of the vault.
SA Consumer Products shall only be responsible and liable when the
vault is used in compliance with the direcons specified in your new
SA Consumer Products owner’s manual.
SA Consumer Products
requires that specific guidelines be
followed for repair. The vault will be repaired in-home if possible
(to include parts and labor); however, if factory replacement
is necessary (at
SA Consumer Products
’ sole discreon), the
replacement will be shipped freight prepaid, curbside delivery.
This warranty is inclusive and is in lieu of any and all other
warranes, express or implied. Specifically excluded are the
warranes of merchantability and fitness for a parcular purpose.
This warranty is limited to the vault itself and/or its value and
does not include consequenal damages of any kind including,
but not limited to, the contents in and of the vault.
Table of contents
Other Sanctuary Safe manuals

Sanctuary
Sanctuary DIAMOND SA-DIA1-COM User manual

Sanctuary
Sanctuary Diamond SA-DIA1 User manual

Sanctuary
Sanctuary Platinum SA-PLAT1-BIO User manual

Sanctuary
Sanctuary SA-PS1D User manual

Sanctuary
Sanctuary BIOMETRIC SA-DIA1-BIO User manual

Sanctuary
Sanctuary PLATINUM SA-PLAT1 User manual

Sanctuary
Sanctuary SA-PV1M-BIO User manual

Sanctuary
Sanctuary SA-PV2M User manual

Sanctuary
Sanctuary SA-DIA4 User manual