manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Saso
  6. •
  7. Security Sensor
  8. •
  9. Saso SASO-PB D User manual

Saso SASO-PB D User manual

Other Saso Security Sensor manuals

Saso PA-4010PQ User manual

Saso

Saso PA-4010PQ User manual

Saso SASO-PB200L User manual

Saso

Saso SASO-PB200L User manual

Saso SASO-PB10S User manual

Saso

Saso SASO-PB10S User manual

Saso CS-10N User manual

Saso

Saso CS-10N User manual

Saso PA-0112 User manual

Saso

Saso PA-0112 User manual

Saso SASO PB100A User manual

Saso

Saso SASO PB100A User manual

Saso PA-4610P User manual

Saso

Saso PA-4610P User manual

Saso PB60-S User manual

Saso

Saso PB60-S User manual

Saso PA-4510P User manual

Saso

Saso PA-4510P User manual

Saso SASO-SH10 User manual

Saso

Saso SASO-SH10 User manual

Saso PA-4109W User manual

Saso

Saso PA-4109W User manual

Popular Security Sensor manuals by other brands

Honeywell Home PROSiXCOCN Installation and setup guide

Honeywell Home

Honeywell Home PROSiXCOCN Installation and setup guide

Duevi SIRPZ-RB-868 Operation

Duevi

Duevi SIRPZ-RB-868 Operation

RKI 65-2483RK Operator's manual

RKI

RKI 65-2483RK Operator's manual

Nortech PD160 Enhanced Series user manual

Nortech

Nortech PD160 Enhanced Series user manual

Omron K8AC-H2 manual

Omron

Omron K8AC-H2 manual

Agilent Technologies G8610 Series Quick reference card

Agilent Technologies

Agilent Technologies G8610 Series Quick reference card

Shinko SE2EA-1-0-0 instruction manual

Shinko

Shinko SE2EA-1-0-0 instruction manual

Det-Tronics X Series instructions

Det-Tronics

Det-Tronics X Series instructions

ACR Electronics COBHAM RCL-300A Product support manual

ACR Electronics

ACR Electronics COBHAM RCL-300A Product support manual

TOOLCRAFT 1712612 operating instructions

TOOLCRAFT

TOOLCRAFT 1712612 operating instructions

Elkron IM600 Installation, programming and functions manual

Elkron

Elkron IM600 Installation, programming and functions manual

Bosch WEU PDO 6 Original instructions

Bosch

Bosch WEU PDO 6 Original instructions

THORLABS PDA10JT user guide

THORLABS

THORLABS PDA10JT user guide

Waeco UV-DETECT operating manual

Waeco

Waeco UV-DETECT operating manual

Intermatic IOS-DSIMF manual

Intermatic

Intermatic IOS-DSIMF manual

Siemens AZL66 Series manual

Siemens

Siemens AZL66 Series manual

BTI Profiline Multi Finder operating instructions

BTI

BTI Profiline Multi Finder operating instructions

Challenger SL01 instruction manual

Challenger

Challenger SL01 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Photoelectric Beam Detector
SASO-PB D
Installation Instructions
Please note : This sensor is designed to detect intrusion and to initiate an alarm,
it is not a burglar-preventing device. Maker is not responsible for damage, ,injury
or losses caused by accident, theft, natural disasters, abuse, misuse, abnormal usage,
faulty installation or improper maintenance.
1. Description
Response time
adjustment
Terminals
Good LED Tamper
Wiring Hole
Power LED
Tamper
Alarm LED
Lens
Monitor jack
Vertical
Adjustment screw
View finder
Cover Transmitter
Receiver Plate
2. Cautions on Installation
3. Installation
3-1. Wall mount
Avoid direct
contact of sun,
auto-mobile head-
lights etc. to
transmitter or
receiver
Do not install the
unit on unsteady
surfaces.
Do not install in a
site where beams
may be interrupted
by trees or plants.
Do not install in
places where
units may be
splashed
continuously by
dirty water or
direct sea spray.
①Remove cover from unit
and slide the mounting
plate to detach it.
②Break grommet on mounting plate
and pull wire through it. Secure
the plate with 4mm screws.
③When exposed wired, break knock-
outs on the rear of unit, pull wire
through as the figure and attach it to
the mounting plate.
④After wiring is completed,
adjust alignment, check
operation and attach cover.
3-2. Pole mount (Pole size : Φ38 ~ Φ44mm)
①Remove cover from unit and slide the mounting plate to detach it.
②Attach pole brackets to pole and secure to mounting plate with screws.
③Attach sensor body.
④Pull through wire.
⑤Connect terminals.
⑥After wiring is completed, adjust alignment, check operation and attach cover.
4 Response time
1. Run at full speed
(6.9m/s) - 50msec. 2. Walk with quick steps
(1.2m/s) - 200msec. 3. Walking (0.7m/s)
- 300msec. 4. Walk with slow steps
(0.5m/s) - 500msec. 5~6. Go over a fence(0.3m/s)
- 700msec.
4
.
Response
time
Response time
adjustment
50ms 700ms
5. Channel setting
Purpose of this function is to prevent cross-talk or bypass of
beams which may occur in line protection or 2-stacked protection.
1ch 2ch 3ch 4ch
6. Wiring
TransmitterReceiver Terminal configuration
VCC : DC10.8~25V
GND
NO
1
2
NO
5
6
Terminal configuration
Normal Open
Tamper
T
①②③④⑤⑥⑦ ①② ⑥
7. Adjustment and Monitoring
- Monitoring
Normal Close
Common
3
4
7
T
ampe
r
Look through view finder on either side and
line-up optics horizontally and vertically until
the opposite unit is visible.
8 Trouble Shooting
Alignment GoodONAbove 3.1 V
Alignment againOFFLess than 3.0 V
ConditionR:Green LEDMonitoring
Vertical
Adjustment :±10˚
Horizontal
Adjustment :±95˚
Digital
Multi meter
Trouble
Power LED dose not light.
Alarm LED does not light when two
beams are broken simultaneously.
No contact under the set condition
Good LED does not operate
8
.
Trouble
Shooting
Possible cause
No power supply.
Bad wiring connection or short.
No power supply.
Bad wiring connection or short.
Resistor short.
Malfunction
Possible Solution
Input DC 10.8 ~25V.
Check wiring connection and repair
if necessary.
Replace.
Replace.
Tx
Rx
9. Specifications
Model SASO-PB30D (4-ch) SASO-PB60D (4-ch) SASO-PB100D (4-ch)
Detection system Simultaneous breaking of 2 beams
Infrared beam Double modulation pulsed beams by LED
Protection range Outdoor 30m Outdoor 60m
Indoor 60m Indoor 120m Outdoor 100m
Indoor 200m
Supply voltage 10.8V ~ 25V DC (Polarity)
Current Max. 60mA
6
Response time 50 ~ 700 ms
LED Transmitter Green LED ON : Power ON
Receiver Green LED(Sensitivity Good) / Red ON : When an alarm is initiated
Alarm output Dry contact relay output 1C
Contact action : Interruption time & delay time(2+0.5 sec)
Contact capacity : 30V(AC/DC) 1A or less
Tamper output Dry contact relay output form N/C
Contact action : Activated when cover is detached
Contact capacity : 30V(AC/DC) 1A or less
Temperature -30℃~ 60℃
177 8
Beam adjustment Horizontal : 190˚(±95˚), Vertical : 20˚(±10˚)
Mounting position Outdoor / Indoor
Material PC resin
IP rating IP 54
External dimensions 80 x 177 x 86 mm(WxHxD)
Weight Rx : 315g, Tx : 305g
Function Monitor jack output, Frost proof cover
Option Pole attachment(2pcs./set) / IP 54
80
.
* Caution : Please refer to the instruction manual to ensure proper operation of the product.