manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Saso
  6. •
  7. Security Sensor
  8. •
  9. Saso PA-4109W User manual

Saso PA-4109W User manual

Passive Infrared Detector
PA-4109W
Installation Instructions
Notice : This detector is designed to detect an intruder and to sound alarm when
detected; it is not to prevent burglary. We are not responsible for damage or losses
from accident, theft, natural calamity, misuse, abnormal use, improper installation
and bad maintenance.
1. Description & Coverage and Range
Side view
-WIDE
Top view
COVER
Sensitivity
Adjustment
Sensor
N.C/N.O
LED
ON/OFF
2. Cautions on Installation
LENS
CABLE
Sensor
LED
BASE
Wire Terminal
-SPOT
Side viewTop view
Please install the detector in the
desirable detection site.
Please avoid installing it where
electric noise and vibration is
prevalent.
Please avoid direct sunlight to
the detector.
Please do not install the detector
outdoor. (Indoor use only)
3. Installation
1) Separate the cover 3) Close the cover.2) Mount the detector on the wall.
- Wall Installation
1) Separate the cover 3) Close the cover.2) Mount the detector on the
ceilling.
- Ceiling Installation
kI lli
-Brac
k
et
I
nsta
ll
at
i
on
1) Separate the cover 2) Connect the cables together. 3) Install the detector on the bracket.
4) Close the cover..
5) Lock the lever in the bracket
-
Wall mounting
-
Ceiling mounting
4) Close
the
cover..
5)
Lock
the
lever
in
the
bracket
.
Wall
mounting
Ceiling
mounting
4. Wiring & JUMPER PIN
-CABLE -
Sensitivity
Adjustment
-
ALARM
-
LED(ON/OFF)
Red (+12V)
Sensitivity
Adjustment
ON(Fast)
OFF(Slow)
ALARM
LED(ON/OFF)
※Caution
Do not connect the power supply to
the alarm wires.
Black (0V)
Yellow (Alarm)
Green (Alarm)
N.C
N.O
ON
OFF
※ Sensitivity
ON : Fast
OFF : Slow
※ JUMPER PIN
ON : Closed
OFF : Open
5. Troubleshooting
Symptoms Cause Solution
When LED is not turned on, Lines of electricity source are cut. Check the lines
Electricity source is not correct. Check it to DC 8 ~ 18V
No contact point although it is set Cutting lines or abnormality of inner circuit Check the lines of connection
No contact point when detected Cutting lines or abnormality of inner circuit Check the lines of connection
LED is not working when detected Cutting lines, LED broken down or
abnormality of inner circuit. Check the lines of connection
When there is abnormal working
There is dirt on the cover Remove dirt with soft cloth
When it is exposed to direct ray of light Install it to another place or block the light
When it can’t detect normally Adjust the scope of alert
6. Specification & Dimension
Model PA-4109W
Description Passive Infrared motion detecting
Detection Range WIDE Angle : 9m / SPOT : 6m
Zone 31 Pairs (62 Zone)
Supply Voltage DC 8 ~ 18V (Polarity)
Current 25mA (MAX)
Alarm Output Dry Contact Relay Output (NC/NO)
Temperature -20℃ ~ 60℃
Mounting Site Indoor
Material COVER, BASE: ABS resin / LENS: PE resin
※Caution : This specification may be changed without prior notice for development
Dimension 39 x 62 x 30mm
Weight 27g
Features Auto Sensitivity Inhibition Control, etc.

Other Saso Security Sensor manuals

Saso CS-10N User manual

Saso

Saso CS-10N User manual

Saso PB60-S User manual

Saso

Saso PB60-S User manual

Saso PA-0112 User manual

Saso

Saso PA-0112 User manual

Saso PA-4010PQ User manual

Saso

Saso PA-4010PQ User manual

Saso SASO PB100A User manual

Saso

Saso SASO PB100A User manual

Saso SASO-PB D User manual

Saso

Saso SASO-PB D User manual

Saso PA-4610P User manual

Saso

Saso PA-4610P User manual

Saso SASO-PB10S User manual

Saso

Saso SASO-PB10S User manual

Saso SASO-SH10 User manual

Saso

Saso SASO-SH10 User manual

Saso SASO-PB200L User manual

Saso

Saso SASO-PB200L User manual

Saso PA-4510P User manual

Saso

Saso PA-4510P User manual

Popular Security Sensor manuals by other brands

BURG-WACHTER BURGsmart Protect WATER 2062 Assembly and user manuals

BURG-WACHTER

BURG-WACHTER BURGsmart Protect WATER 2062 Assembly and user manuals

Theben compact office EIB installation manual

Theben

Theben compact office EIB installation manual

Risco ViTRON RWT6G installation instructions

Risco

Risco ViTRON RWT6G installation instructions

Surface Concept HVPS manual

Surface Concept

Surface Concept HVPS manual

Dors 200 user manual

Dors

Dors 200 user manual

ELRO AG40PR11 manual

ELRO

ELRO AG40PR11 manual

Chamberlain 771E-02 quick start guide

Chamberlain

Chamberlain 771E-02 quick start guide

Emerson Mobrey Instruction leaflet

Emerson

Emerson Mobrey Instruction leaflet

Varian 380-LC Service manual

Varian

Varian 380-LC Service manual

Basalte AURO 0180-02 installation manual

Basalte

Basalte AURO 0180-02 installation manual

Wetekom 92 23 77 instruction manual

Wetekom

Wetekom 92 23 77 instruction manual

ABB Busch-Watchdog 6747-500 AGM Series operating instructions

ABB

ABB Busch-Watchdog 6747-500 AGM Series operating instructions

Eagle L112F manual

Eagle

Eagle L112F manual

Honeywell NFPA 1971 User's information guide

Honeywell

Honeywell NFPA 1971 User's information guide

Recco R9 quick guide

Recco

Recco R9 quick guide

SICK deTec4 Core operating instructions

SICK

SICK deTec4 Core operating instructions

SKYLOTEC LORY Series Instructions for use

SKYLOTEC

SKYLOTEC LORY Series Instructions for use

FDD CR 135-2C installation instructions

FDD

FDD CR 135-2C installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.