Satel OPAL Plus User manual

OPAL Plus
Outdoor dual technology motion detector
Firmware version 3.00 opal_plus_en 03/21
SATEL sp. z o.o. •ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.eu

IMPORTANT
The device should be installed by qualified personnel.
Prior to installation, please read carefully this manual.
Changes, modifications or repairs not authorized by the manufacturer shall void your rights
under the warranty.
SATEL aims to continually improve the quality of its products, which may result in changes in
their technical specifications and software. Current information about the changes being
introduced is available on our website.
Please visit us at:
https://support.satel.eu
The declaration of conformity may be consulted at www.satel.eu/ce
The following symbols may be used in this manual:
- note,
- caution.

CONTENTS
1. Features ...........................................................................................................................2
2. Description........................................................................................................................2
Anti-mask feature .............................................................................................................2
Dusk sensor......................................................................................................................2
Supervision features.........................................................................................................3
LED indicators..................................................................................................................3
Remote configuration mode enable / disable....................................................................4
3. Electronics module ...........................................................................................................4
4. Installation ........................................................................................................................5
Wall mounting...................................................................................................................8
Angle bracket mounting....................................................................................................8
Ball bracket mounting.......................................................................................................9
Connecting the additional tamper switch........................................................................11
5. Configuring the detector .................................................................................................11
Starting configuration mode............................................................................................11
Signaling in the configuration mode................................................................................11
Configuring by means of the detector buttons ................................................................12
Configuring by means of OPT-1 keyfob..........................................................................12
Ending configuration mode.............................................................................................12
6. Start-up and walk test.....................................................................................................12
Separate testing of sensors............................................................................................13
7. Specifications .................................................................................................................13

2 OPAL Plus SATEL
The OPAL Plus detector detects motion in the protected area. It is designed for outdoor use.
This manual applies to the detector with electronics version D. The detector meets the
requirements of the EN 50131-2-4 standard for Grade 2.
The Grade 2 certificate applies to the indoor use. The outdoor use of the
detector (despite full Grade 2 functionality) is not covered by the certificate
(there is no standard for the outdoor detectors).
1. Features
Motion detection with two sensors: passive infrared sensor (PIR) and microwave sensor
(MW).
Digital motion detection algorithm.
Digital temperature compensation.
Pet immunity up to 20 kg.
Immunity to false alarms caused by objects moving but not changing their position
(e.g. branches of trees).
Creep zone.
Microwave based anti-mask feature.
Dusk sensor.
Capability of separate sensor configuring / testing.
Sensitivity configuration by means of OPT-1 keyfob.
Three LED indicators.
Remote LED enable / disable.
Remote configuration mode enable / disable.
Supervision of motion detection system and supply voltage.
Tamper protection against cover removal and tearing enclosure from the wall.
Weatherproof enclosure featuring a very high mechanical strength.
2. Description
The alarm will be triggered when infrared sensor (PIR) and microwave sensor detect motion
within a time period shorter than 4 seconds.
Anti-mask feature
Detection by the microwave sensor of an object moving at a distance of 10-20 centimeters
from the detector is interpreted as an attempt to mask the detector and results in activation of
anti-mask output for two seconds. Objects permeable to microwaves, but isolating the
infrared radiation are not detected by the anti-mask feature.
The anti-mask feature meets the EN 50131-2-4 requirements.
Dusk sensor
Figure 1 shows the way the dusk sensor operates. On the timeline the T time delay is
presented (in operating mode T=3 min, in configuration mode T=3 s). Illustrated with the
letter H light intensity hysteresis and time delay make the sensor immune to short and

SATEL OPAL Plus 3
accidental changes of light intensity. Table 1 presents light intensity values for three out of
sixteen programmable detection thresholds of the sensor (see “Configuring the detector”).
Light intensity
Detection
threshold
Turning on [PON]
Turning off [POFF]
minimum
2 lx
3 lx
default
16 lx
20 lx
maximum
200 lx
250 lx
Table 1
Supervision features
In the event of the voltage drop below 9 V (± 5%) for more than 2 seconds or the motion
detection system failure, the detector will signal a trouble. The trouble is indicated by the
activation of alarm output and the steady light of all LED indicators. The trouble signaling will
continue as long as the trouble persists.
LED indicators
The LEDs indicate:
warm-up –all LEDs flashing alternately for about 40 seconds;
motion detected by microwave sensor –green LED ON for 4 seconds;
motion detected by PIR sensor –yellow LED ON for 4 seconds;
alarm –red LED ON for 2 seconds;
trouble –all LEDs ON for entire duration of the trouble.
The LEDs are also used in the configuration mode (see: “Configuring the detector”).
You can enable / disable the LEDs. When disabled, the LEDs will not indicate the states
described above.

4 OPAL Plus SATEL
Enabling the LEDs by using a jumper
If you put a jumper across the LED pins, the LEDs will be enabled, i.e. they will indicate the
events described above (the LED indicators can’t be enabled / disabled remotely). If you do
not put a jumper across the pins, the LEDs will be disabled, but they can be
enabled / disabled remotely.
Remote LEDs enable / disable
The LED terminal is provided to allow remote LEDs enable / disable. When the terminal is
connected to common ground, the LEDs are enabled. When the terminal is disconnected
from common ground, the LEDs are disabled.
If the detector is used in the INTEGRA / INTEGRA Plus alarm system, you can connect to
the terminal the OC type control panel output programmed e.g. as “Zone test status” or “BI
switch”.
Remote configuration mode enable / disable
The SVCE terminal is provided to allow remote configuration mode enable / disable.
The configuration mode is enabled, when the terminal is connected to the common ground.
If the detector is used in the INTEGRA / INTEGRA Plus alarm system, you can connect to
the terminal the OC type control panel output programmed e.g. as “Service mode status” or
“BI switch”.
3. Electronics module
Do not remove the plastic cover from the circuit board to prevent damage to the
components located on the board.
Do not touch the pyroelectric sensor, so as not to soil it.

SATEL OPAL Plus 5
terminals:
AM - anti-mask output (NC relay).
TMP - tamper output (NC).
NC - alarm output (NC relay).
COM - common ground.
+12V - power input.
LED - remote LED control.
SVCE - remote control of configuration mode.
D/N - dusk sensor output (OC type output).
pins to enable / disable the LED indicators.
microwave sensor.
green LED.
red LED.
yellow LED.
infrared receiver allowing to configure the detector by means of OPT-1 keyfob.
The keyfob is offered by SATEL.
buttons used during sensors sensitivity setting.
MODE button used for the detector configuration (see: “Configuring the detector”).
PIR sensor (dual element pyrosensor).
tamper switch activated by cover removal.
fixing screw holes.
dusk sensor.
On the other side of the electronics module there is a tamper switch activated by removing
the detector from the wall.
When mounting the detector on the angle or ball bracket, it is necessary to install
additional tamper switch (it is included in the detector delivery set).
4. Installation
Disconnect power before making any electrical connections.
If the detector is to be pet immune, it should be mounted at 2.4 m height with no
vertical tilt. It is especially important when mounting on a ball bracket.

6 OPAL Plus SATEL
Install the detector at the recommended height (Fig. 3-I).
If traffic nearby or objects moving out of the protected area cause an alarm, move the
detector slightly downwards or reduce the detector sensitivity (Fig. 3-II).
Install the detector so that the expected movement of an intruder will be across the
coverage pattern (Fig. 3-III).
Don’t install the detector closer than 3 meters from the moving objects (e.g. tree
branches, bushes, laundry etc.) (Fig. 3-IV).
Don’t direct the detector on reflective surfaces or on fans or a heat sources (Fig. 3-V).
When putting two or more cables into the enclosure, it is advisable to place them in
heat shrink tube. It reduces the risk of getting water into the enclosure.
1. Remove the front cover (Fig. 4).
2. Remove the electronics module (Fig. 5).

SATEL OPAL Plus 7
3. Make the opening for cable in the enclosure base.
4. Mount the enclosure base to the wall (see: “Wall mounting”), to the angle bracket (see:
“Angle bracket mounting”) or to the ball bracket (see: “Ball bracket mounting”). In Figure 6
possible ways of mounting the detector are shown.
5. Fasten the electronics module in the enclosure base.
6. Connect the wires to the corresponding terminals.
7. Configure the detector (see: “Configuring the detector”).
8. Replace the cover.

8 OPAL Plus SATEL
Wall mounting
1. Run the cable through the opening in the enclosure base.
2. Using wall plugs (screw anchors) and screws, fasten the enclosure base to the wall.
Angle bracket mounting
1. Attach extra tamper switch:
–screw the holder to the tamper switch (Fig. 7-I),
–screw the tamper unit to the enclosure base (Fig. 7-III).
Figure 7 shows mounting the tamper switch in one of two available positions.
The place of tamper switch installing depends on the way of angle bracket mounting.
If the tamper switch is to be installed in the other position, place tamper switch holder
on the other side.
2. Prepare openings in the bracket for screws and a cable.
3. Pass the cable through the prepared opening.
4. Using wall plugs (screw anchors) and screws, fasten the bracket to the wall.
5. Run the cable through the opening in the enclosure base.
6. Using screws, fasten the enclosure base to the bracket (Fig. 7-IV).
Other manuals for OPAL Plus
1
Table of contents
Other Satel Security Sensor manuals

Satel
Satel GREY User manual

Satel
Satel VD-1 User manual

Satel
Satel ADD-200 User manual

Satel
Satel TD-1 User manual

Satel
Satel AQUA S User manual

Satel
Satel ARD-100 User manual

Satel
Satel AQUA User manual

Satel
Satel GRAPHITE User manual

Satel
Satel abax 2 ADD-200 User manual

Satel
Satel micra MXD-300 User manual

Satel
Satel COBALT User manual

Satel
Satel AQUA RING User manual

Satel
Satel SILVER User manual

Satel
Satel COBALT Pro User manual

Satel
Satel DMP-100 User manual

Satel
Satel INDIGO User manual

Satel
Satel ASD-100 User manual

Satel
Satel SILVER User manual

Satel
Satel GRAPHITE Pet User manual

Satel
Satel GRAPHITE User manual