2 APD-200 Pet SATEL
The APD-200 Pet detector is used to detect motion in a protected area. It is designed for
operation within the ABAX 2 / ABAX two-way wireless system. This manual applies to the
detector with firmware version 1.00 (or newer), which is supported by:
ABAX 2:
–ACU-220 / ACU-280 controller,
–ARU-200 repeater.
ABAX:
–ACU-120 / ACU-270 controller (firmware version 5.04 or newer),
–ARU-100 repeater (firmware version 2.02 or newer),
–INTEGRA 128-WRL control panel (firmware version 1.19 or newer and firmware
version of processor used to operate ABAX system 3.10 or newer).
1. Features
Motion detection with passive infrared sensor (PIR).
Digital motion detection algorithm.
Digital temperature compensation.
Pet immunity up to 20 kg.
Encrypted two-way radio communication in the 868 MHz / 915 MHz frequency band (AES
standard for the ABAX 2 system).
Transmission channel diversity –4 channels for automatic selection of the one that will
enable transmission without interference with other signals in the 868 MHz / 915 MHz
frequency band (ABAX 2 system only).
Remote update of detector firmware (ABAX 2 system only).
Remote configuration.
Built-in temperature sensor (temperature measurement range from -10°C to +55°C).
LED indicators.
Supervision of motion detection system.
“ECO” option for longer battery life (ABAX 2 system only).
Battery status control.
Tamper protection against enclosure opening and removal from mounting surface.
2. Specifications
Operating frequency band................................868.0 MHz ÷868.6 MHz / 915 MHz –928 MHz
Radio communication range (in open area)
ABAX 2
ACU-220 ..............................................................................................up to 2000 m
ACU-280 ..............................................................................................up to 1600 m
ABAX..............................................................................................................up to 500 m
Battery....................................................................................................................CR123A 3 V
Battery life expectancy..........................................................................................up to 2 years
Temperature measurement range .......................................................................-10°C...+55°C
Temperature measurement accuracy ................................................................................±1°C
Standby current consumption .......................................................................................... 70 µA