Page 6 Page 7
Feature
Door Lock / Unlock Pulse Duration
Driver’s Priority Unlock
Double Pulse Unlock
Dome Light Factory Rearm
0.8 sec
OFF
OFF
OFF
2.5 sec
ON
ON
ON
Factory Default
Setting - Button Optional
Setting - Button
Remote-Page P og amming Menu Options
This feature unlocks the driver s side door lock with the first unlock pulse.
A second unlock pulse is need to unlock the rest of the car doors.
In order for this feature to operate, the installer must use the 2nd
Unlock Wire (Light Blue wire of Connector 4). Isolate the driver s door actuator from
the rest of the other doors. Call us for technical support if you are not sure about
this.
1. Enter programming by pressing:
a. The (lock) button, and the (unlock) button simultaneously until the parking lights
flash once. This is Menu 1.
b. The (lock) button, and the (start/stop) button simultaneously until the parking
lights lash once. This is Menu 2.
2.
Press the (trunk) button and the (start/stop) button simultaneously unti the
parking lights flash, the number of times equal to the option you would like to change.
For example, if it were the th option in the menu that you would like
to change, you would press the (trunk) and (start/stop) buttons simultaneously five
times.
3.Wait a few seconds, and the parking lights will flash the number of times
corresponding to the option number you are about to modify. If the number of times
the lights flash does not correspond with the option you want to change, wait a few
seconds and the siren/horn will sound, signaling that you have exited programming
mode. After the siren/horn sounds, you can retry the process from the beginning.
4. Immediately after the parking lights stop flashing from step 3, press:
a. The (lock) button for the factory default setting. The parking lights will flash once.
b. The (unlock) button for the optional setting. The parking lights will flash twice.
You will need to perform these steps for each option you would like to change.
Option P og amming Fo Fou Button Remotes With
Sepa ate Lock & Unlock Buttons
Programming 4 Button Remote ICON
(I+II)-
(I+IV)-
(IV)
( I )
( II )
( III )
Programming Menu 1
Programming Menu 2
Option Selection
Factory Setting
Optional Setting
Default Setting Selection