DIGITAL TYRE INFLATOR 0.5M HOSE WITH TWIN
PUSH-ON CHUCK, DIGITAL TYRE INFLATOR
2.7M HOSE WITH CLIP-ON CONNECTOR
Model no: SA374, SA375
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
9 Disconnectthetyreinatorfromtheairsupplybeforechangingaccessories,servicingorperforminganymaintenance.
9 Keepchildrenandunauthorisedpersonsawayfromtheworkarea.
9 KeepthegaugeLCDscreenandtyreinatorclean.
9 ReplacedamagedpartswithgenuineSealeyparts.Unauthorisedpartsmaybedangerousandwillinvalidatethewarranty.
9 Checkconditionofthebatteriesregularly.
9 Checktyrepressureswhentheyarecold.
8DO NOTdirectthetyreinatoroutletatyourselforothersincludinganimals.
8DO NOTcarrythetyreinatorbythehose,ortugthehosefromtheairsupply.
8DO NOTusethetyreinatorforataskwhichitisnotdesignedtoperform.
8DO NOToperatethetyreinatorwhenyouaretiredorundertheinuenceofintoxicatingmedicines,drugsoralcohol.
8DO NOToperatethetyreinatorifpartsaremissingortheLCDisdamaged,thiscouldbedangerous.
8DO NOTdroporbumpthetyreinator.
8DO NOTgetthetyreinatorwet.
8DO NOToperatenearapplianceswithstrongmagneticelds,corrosivegassesorcorrosiveliquids.
2. INTRODUCTION
2.1. SA374
die-castaluminiumbodywithlargerubberbumper,backlitLCDdigitaldisplayandbatterylevelindicator.Autopoweroaftereightseconds
andautopowerononcepressureissensed,orairinationstarts.0.5mFlexiblehosettedwith240mmpush-onairconnector.Suppliedwith
aserialnumberedcalibrationcerticate.
2.2. SA375
diecastaluminiumbodywithlargerubberbumper,backlitLCDdigitaldisplayandbatterylevelindicator.Autopoweroaftereightseconds
andautopowerononcepressureissensed,orairinationstarts.2.7mFlexiblehosettedwithclip-onairconnector.Suppliedwithaserial
numberedcalibrationcerticate.
3. SPECIFICATION
Model No:.............................................................................SA374....................................................................... SA375
Accuracy:................................................................. 25-75psi±2psi...........................................................25-75psi±2psi
BatteryRunTime:...................................................................80hrs......................................................................... 80hrs
Battery:.............................................................. 2xAAA(supplied)..................................................... 2xAAA(supplied)
InletSize:........................................................................... 1/4”BSP.....................................................................1/4”BSP
MaximumAirSupply:..............................................13.8bar(200psi)......................................................... 13.8bar(200psi)
nettWeight:..........................................................................1.15kg....................................................................... 1.15kg
PressureUnits:............................................................bar,psi,kPa.............................................................. bar,psi,kPa
Range:................................................................ 0-12bar(0-174psi)......................................................0-12bar(0-174psi)
4. OPERATION
4.1. TO READ PRESSURE
4.1.1. Placehold-onchucksquarelyandrmlyontotyrevalve,beforeeachpressurereadingfullydepressleverandrelease.
4.1.2. Checkpressuregauge,thedigitaldisplaywillactivateoncethetyrepressureissensed.Ifnopressureissensedthedisplaywillnot
turnon,pleasepresstriggertoaddairintotyre,beforereadingpressure.
4.2. TO INFLATE
4.2.1. Placechucksquarelyandrmlyontothevalve.Fullydepressleverforanappropriateperiodthenreleaselevertodisplay
pressure.Checkpressuregaugeandrepeatprocedureuntilcorrectpressurelevelisachieved.
4.3. TO DEFLATE
4.3.1. Depressleverhalfway(untilaircanbeheardescaping)foranappropriateperiod,fullydepresslevermomentarilythenreleaseto
displaynewpressure.Checkpressuregaugeandrepeatprocedureuntilcorrectpressurelevelisachieved.
SA374SA375Issue110/06/19
Original Language Version
©JackSealeyLimited
Referto
instructions