SECO-LARM Electromagnetic Gate Lock with Weldable Bracket
4SECO-LARM U.S.A., Inc.
The information and specifications printed in this manual are current at the time of publication.
-LARM policy is one of continual development and improvement. For this reason, SECO-
LARM reserves the right to
change specifications without notice.
SECO-LARM is also not responsible for misprints or typographical errors.
SECO-LARM U.S.A., Inc. All rights reserved.
This material may notbe reproduced or copied, inwhole or
in part, without the written permission of SECO
-LARM.
This SECO-LARM product is warranted against defects in material and workmanship while used in normal
service for the lifetime of the product
. SECO-
LARM’s obligation is limited to the repair or replacement ofany defective part if
the unit is returned, transportation prepaid, to SECO
-LARM.
This Warranty is void if damage is caused by or attributed to
acts of God, physical or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty
installation, or if for any other reason SECO
-LARM determines that s
uch equipment is not operating properly as a result of
causes other than defects in material and workmanship.
The sole obligation of SECO-
LARM and the purchaser’s exclusive
remedy, shall be limited to the replacement or repaironly, at SECO
-LARM’s option. In no event shall SECO-
LARM be liable
for any special, collateral, incidental, or consequential personal or property damage of any kind to the purchaser or anyone
else.
16842 Millikan Avenue, Irvine, CA, 92606
Website: www.seco-larm.com
PITSW1
Phone: (949) 261-2999 | (800) 662-0800
Email: sales@seco-larm.com
Order Part# 764-024-3%
MiE-94xFC-xxxSQ_140515.docx
The gate does not lock
•Check that the wires are secure
•Check that the power supply is connected and operational
•
Check that the unit is wired correctly
The gate locks, but can be easily
forced open
•Check that the electromagnet and armature plate are
properly aligned
•Check that the contact surfaces of the electromagnet and
armature plate are clean and free from rust
•Check the power leads with a meter, and make sure the
correct voltage is present
There is a delay in the gate releasing
•The electromagnet is fitted with a metal oxide varistor to
prevent interference, so do not install a secondary diode
1. Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non-abrasive,
non-corrosive cleaner.
Apply a light coat of a silicon lubricant to both contact surfaces and wipe away the excess to prevent rust
buildup.
Check that the armature plate is securely attached to the bracket, yet can pivot slightly around the
armature screw.
Check that the electromagnet is securely attached to the bracket.
UL CERTIFICATION: The E-946FC-1K2Q, E-942FC-1300, and E-942FC-600 electromagnetic locks conform to
UL/10B “Fire Tests of Door Assemblies” and UL/10C “Positive Pressure Fire Tests of Door Assemblies” for swinging door
assemblies. They are also classified in accordance with theUniformBuilding Code standard 7
-2.