If there are two of the same air
conditioners installed, they cannot be
controlled separately. When you operate
either remote, it will turn on both air
conditioners if they are both within signal
range (6 metres).
Care of your emote ontrolR C
Don’t let the remote control drop onto
hard surfaces or be subjected to sudden
shocks any . The warranty doesof form
not cover misuse or accidental damage.
Don’t place the remote control in direct
sunlight, or near extremes of temperature.
Don’t allow the remote control to get wet.
Don’t place near strong electromagnetic
waves.
Don’t mix old and new batteries!
If the remote control will not be used for a
long time, remove the batteries to avoid
corrosion.
Preparation efore perationB O
Remove the battery cover and insert new
batteries (AAA), making sure the + and -
match the compartment markings (Fig ).10
During Operation
If the remote control will not operate the air
conditioner, the batteries may need to be
replaced.
Remove the batteries and replace with new
ones. If this does not solve the problem
contact your nearest service centre for
advice.
Note! The air conditioner must be plugged in
and switched on for the remote control to
operate the air conditioner. To use, point at
the signal receiving window on the front
panel and press the remote button (Figure
8). The air conditioner will “beep” when a
signal has been received. If there is no beep,
press the remote button again, ensuring it is
within range (6 metres) of the air conditioner.
!
NOTE:
WASTE BATTERIES SHOULD
BE DISPOSED OF CORRECTLY
REMOTE CONTROL
9
Signal
transmission point
Signal
transmission point
Power ON / OFF
button
Power ON / OFF
button
Fan speed
adjust button
Fan speed
adjust button
Timer on / off
button
Timer on / off
button
Mode buttons
(Cool- Dehumidify-Fan)Heating-
Mode buttons
(Cool Dehumidify-Fan )- -Heating
Timer on / adjust
button
Temperature /Timer
adjust buttons
Battery
compartment
Battery
compartment
10
6CP15HW1 Portable Reverse Cycle Air Conditioner
Starting the air conditioner
Step 1: Ensure the cooler is plugged in
and switched on.
Step 2: Lift up the air outlet vent ready for
use.
Step : Press the ON/OFF button3
on the emote ontrol or ON/OFF buttonR C
on the ontrol anel to start the airC P
conditioner.
Step :4 Press the MODE button on
the ontrol anel or remote control toC P
select the desired operating mode
indicated by a light colour change on the
Display Panel 8 & 9(Fig ):
lCooling mode - efrigeratedR
cooling ooling will occur if the set. C
temperature is less than the room
temperature. Blue light indicated.
lDehumidifying mode - for extracting
moisture from the air. Yellow Light.
lFan mode - Fan only operation (no
cooling). Green Light.
lHeating Mode - Heating is activated
only if the ambient temperature is
below 25°C. Red light
Step :5 Press on thebuttonsor
C P R Control anel or on the emote ontrol to
select the desired operating ‘set’
temperature.
The set temperature range is 16°C- °C32
for cooling.
T 7°he set temperature range is 16°C-2 C
for heating.
Tip! Do not set the temperature too high
or low. This will consume more power.
24°C is the recommended set
temperature, with high fan speed.
Note! Changing the set temperature will
have no effect in DEHUMIDIFYING or
FAN modes.
Note! The display can toggle between °C
and °F by pressing both the and
buttons on the Control Panel together and
holding for 2 seconds.
Step :6 Press the FAN SPEED button
on the ontrol anel or remote control toC P
adjust the fan speed. Each press will cycle
the fan speed between low, medium and
high.
Note! In Cooling mode, the fan will continue
to run even when the compressor has
cycled off.
Step 7: The air conditioner is fitted with
horizontal . Cair direction vanes arefully
move the vanes to the desired position by
hand (Fig 1 ).1
Important! During operation, water will
collect in the air conditioner’s tank. Please
be careful when moving the air conditioner
to avoid water spillage.
Built in Drain Pump
The condensate produced during operation
will be drained automatically through the
drain hose when the drain pump outlet is
fitted. If Drain Pump Connector is not fitted
then the tank will slowly fill up. If the tank
should fill, the ‘water full’ indicator light will
be lit on the control display and the unit will
shut down until the water tank is drained.
Should this occur, connect Drain Pump
Connector (see Installation, Page 4) or refer
to Maintenance section for draining
instructions.
OPERATION
11
7
SEELEY INTERNATIONAL –OWNER’S MANUAL
ON/OFF
SPEED
TIMER
MODE
UP
DOWN
+
1.5V
1.5V
Battery cover
Battery cover
Important! During cooling mode, water will
collect in the air conditioner’s tank. This
water is reticulated and some will be
exhausted out with the hot air, but will
slowly fill up the tank. This occurs more
quickly in humid conditions. If the tank
should fill, the ‘water full’ indicator will be lit
on the control display and the unit will shut
down. The cooler cannot be restarted until
the water tank is drained. Refer to the
Maintenance section for draining the tank
should this occur.