Compact ultrasonic level transmitter
PTU05 mA GB
PTU05 Mechanica installation
Enclosure material: PP
Mechanical installation: 1” BSP
on request with PP DN100 flange screwed
Mechanical protection: IP68
Electrical connection: n.1 output cables (L=3m)
Working temperature: -25 a +75°C
Pressure: from 0,5 to 1,5bar (absolute)
Power supply: 24Vdc
Power consumption: 1W
Serial port: RS485
Max measure range: 5m
[The above distance must be intended from perfect
reflecting surfaces]
Blocking distance: 0.3m
Temperature compensation: PT100 from -30 to +80°C
Accuracy: +/- 1% not better than +/-2mm
Resolution: 1mm
Calibration: by SWING unit
Warm-up: 30 minutes normally
LEDs display: red LED for supply
yellow LED flashing for echo receiving
fig.1
PTU05
Technical Data
fig.2
A) B) C)
D) E)
Important close to the sensor there is a “blind zone” of 0,3m
where the equipment can’t measure.
To reach a good and safe measurement, avoiding spurious
echo (not reflected from the surface to measure) need to take
care about the sensor sensibility volume in the sound path, no
obstacles or objects must be present into the sensibility volume
(lobe), see fig.2/D/E.
On fig.2 some suggestion:
1) Install perpendiculary at the surface, see fig.2/A
2) Don’t use with foaming products, see fig.2/B
3) Avoid installation where the product distance could be less
than 0,3m, see fig.2/C
4) No obstacles or objects must be present into the .
sensibility volume, see fig.2/D/E
applied solutions for the application