AIR PURIFIER
OPERATION MANUAL
Free standing type
“Plasmacluster” and “Device of a cluster of grapes” are
trademarks of Sharp Corporation.
*The number in this technology mark indicates an
approximate number of ions supplied into air of 1 cm3,
which is measured around the center of a room with
the “high-density plasmacluster 7000” applicable oor
area (at 1.2 m height above the oor) at the medium
wind volume in air purifying mode, when an air purier
using the high-density plasmacluster ion evolving
device is placed close to a wall. This product is
equipped with a device corresponding to this capacity.
OM_FP-F40TA_TH-EN.indb 1 4/10/2558 BE 3:36 PM

OM_FP-F40TA_TH-EN.indb 2 4/10/2558 BE 3:36 PM

ภาษาไทย
T-1
T-2
T-4
T-5
T-6
T-8
T-11
OM_FP-F40TA_TH-EN.indb 1 4/10/2558 BE 3:36 PM

T-2
OM_FP-F40TA_TH-EN.indb 2 4/10/2558 BE 3:36 PM

ภาษาไทย
T-3
OM_FP-F40TA_TH-EN.indb 3 4/10/2558 BE 3:36 PM

T-4
2
1 10
2 11
3
12
4
13
5
14
6 15
7 16
8 17
9 18
9
OM_FP-F40TA_TH-EN.indb 4 4/10/2558 BE 3:36 PM

ภาษาไทย
T-5
1
2
3
5
OM_FP-F40TA_TH-EN.indb 5 4/10/2558 BE 3:36 PM

T-6
OM_FP-F40TA_TH-EN.indb 6 4/10/2558 BE 3:36 PM

ภาษาไทย
T-7
CANCELLATION
1
2
3
OM_FP-F40TA_TH-EN.indb 7 4/10/2558 BE 3:36 PM

T-8
OM_FP-F40TA_TH-EN.indb 8 4/10/2558 BE 3:36 PM

ภาษาไทย
T-9
OM_FP-F40TA_TH-EN.indb 9 4/10/2558 BE 3:36 PM

T-10
OM_FP-F40TA_TH-EN.indb 10 4/10/2558 BE 3:36 PM

ภาษาไทย
T-11
*1
*2
*
OM_FP-F40TA_TH-EN.indb 11 4/10/2558 BE 3:36 PM

HEPA Filter
Deodorizing Filter
Pre-Filter
NOTE
The air purier draws in room air from the air intake, passes the air through a Pre-
Filter, a Deodorizing Filter and a HEPA Filter inside of the unit, then discharges the air
through the air outlet. The HEPA Filter can remove 99.97% of dust particles as small
as 0.3 microns that pass through the lter and also helps absorb odours.
The Deodorizing Filter gradually absorbs odours as they pass through the lter.
Some odours absorbed by the lters may break down over time, resulting in additional
odour. Depending on the usage environment, especially when the product is used in
extreme environments (significantly more severe than normal household use), this
odour may become strong in a shorter period than expected. If the odour persists, the
lters should be replaced.
• The air purier is designed to remove air-suspended dust and odour, but not harmful gases (for
example, carbon monoxide contained in cigarette smoke). If the source of the odour still exists, the
air purier may not completely remove the odour.
Please read before operating your new Air Purier
OM_FP-F40TA_TH-EN.indb 12 4/10/2558 BE 3:36 PM

ENGLISH
E-1
ENGLISH
Thank you for purchasing the SHARP
Air Purier. Please read this manual carefully.
Before using this product, be sure to read the
section: “Important Safety Instructions.”
After reading this manual, keep it in a
convenient location for future reference.
For your reference, we recommend to keep
this manual in the place where you can read
at any time.
IMPORTANT SAFETY INSTRUCTIONS
..... E-2
PART NAMES............................................... E-4
FILTER INSTALLATION .............................E-5
OPERATION .................................................E-6
CARE AND MAINTENANCE .....................E-8
TROUBLESHOOTING ..............................E-10
SPECIFICATIONS...................................... E-11
CONTENTS
FEATURES
Unique Combination of Air Treatment
Technologies
Triple Filtration System + Plasmacluster
TRAPS DUST*
Pre-filter traps dust and other large
airborne particles.
DECREASES ODOURS
Deodorizing filter absorbs many common
household odours.
REDUCES POLLEN & MOLD*
HEPA filter traps 99.97% of particles as
small as 0.3 microns.
FRESHENS
Plasmacluster treats the air similar to the
way nature cleans the environment by
emitting a balance of positive and negative
ions.
*When air is drawn through the filter
system.
Sensor Technology continuously monitors
air quality, and automatically adjusting
operation based on detected air purity.
OM_FP-F40TA_TH-EN.indb 1 4/10/2558 BE 3:36 PM

E-2
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed,
including the following:
WARNING - To reduce the risk of electrical shock, re or injury to persons:
• Read all instructions before using the unit.
• Use only a 220 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the
wall outlet is loosened.
• Periodically remove dust from the power plug.
• Do not insert ngers or foreign objects into the intake or air outlet.
• When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or re from short circuit may occur as a result.
• Be careful not to damage the power cord, it may cause electric shock, excess heat or
res.
• Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or replaces.
• Remove the power plug from the wall outlet before cleaning the unit and when not
using the unit.
Electrical shock from bad insulation and/or re from short circuit may occur as a result.
•When cleaning the unit, or when the unit is not in use, be sure to unplug the unit. Electrical
shock and/or re from a short circuit may result.
• If the power cord is damaged, it must be replaced by the manufacturer, its service
agent, Sharp Approved Service Centre or similarly qualified person in order to
avoid a hazard.
• Do not operate when using aerosol insecticides or in rooms where there is oily residue,
incense, sparks from lit cigarettes, chemical fumes in the air or in very high humidity
conditions, such as a bathroom.
• Be cautious when cleaning the unit. Corrosive cleansers may damage the exterior.
• Only a Sharp Authorized Service Centre should service this air purifier. Contact the
nearest Service Centre for any problems, adjustments, or repairs.
• This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning use of the appliance in a safe
way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
NOTE - Radio or TV Interference
If this air purier should cause interference to radio or television reception, try to correct the
interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the unit and radio/TV/wave-clock receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.
OM_FP-F40TA_TH-EN.indb 2 4/10/2558 BE 3:36 PM

ENGLISH
E-3
CAUTIONS CONCERNING OPERATION
• Do not block the intake and/or air outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters or where it may
come into contact with steam.
• Do not lay the unit down when using.
• Always hold the handle on the back of the unit when moving it.
• Do not use without the lters inside the unit.
• Do not wash and reuse the HEPA lter and the deodorizing lter.
Not only does it not improve lter performance, it may cause electric shock or malfunction.
INSTALLATION GUIDELINES
• When using the unit, place the unit away from equipment utilizing electric waves
such as televisions or radios to avoid electrical interference.
• Avoid use in locations where furniture, fabrics or other items may come in contact
with and restrict the air intake and/or air outlet.
• Avoid use in locations where the unit is exposed to condensation or drastic
temperature changes. Appropriate conditions are when room temperature is
between 0 – 35 ºC.
• Place on a stable surface with sufcient air circulation.
When placing the unit on a heavily carpeted area, the unit may vibrate slightly.
• Avoid locations where grease or oily smoke is generated.
The unit surface may crack as a result.
•Place the unit about 30 cm(1 ft) away from the wall in order to ensure proper
airow.
The dust collecting performance will be the same even if using the unit 3cm away from
the wall, but place it as far as possible(30cm away recommended) because it may dirty
the wall or oor around.
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the lter.
OM_FP-F40TA_TH-EN.indb 3 4/10/2558 BE 3:36 PM

E-4
PART NAMES
18
17
2
1
1Main Unit 10 Dust sensor
2Air Outlet 11 HEPA Filter
3OFF TIMER Button /
LIGHT ON/OFF Button (Press 3 sec.) 12 Deodorizing Filter
4
MODE Button / MODE Indicator Light
(green)
Plasmacluster Ion ON/OFF Button
(Press 3 sec.)
13 Upper Tabs
5CLEAN ION SHOWER Button / CLEAN ION
SHOWER indicator Light (green) 14 Back Panel (Pre-Filter)
6POWER ON/OFF Button 15 Bottom Tabs
7DUST SIGN 16 Power Cord
8PLASMACLUSTER SIGN 17 Plug (Shape of plug depends on country.)
9Handle 18 Date Label
FRONT
BACK
16
13
14
PLASMACLUSTER SIGN
blue Plasmacluster ON
off Plasmacluster OFF
8
7
Clean
Impure
Red
Orange
Green
3 4 5 6
9
10
11
12
15
DUST SIGN
Indicates the air purity of the room
in 3 levels with color changes.
OM_FP-F40TA_TH-EN.indb 4 4/10/2558 BE 3:36 PM

ENGLISH
E-5
FILTER INSTALLATION
To maintain the quality of the lter, it is installed in the main unit and packed in plastic
bag. Be sure to remove the lter from the plastic bag before using the unit.
1
Remove the Back Panel.
2 Remove the plastic bag from
the Filter.
3
Place the Filter within the main
unit.
Do not install the lter backwards or the
unit will not operate properly.
Upper Tabs
• Do not operate the unit without the lter.
Date Label
Pull Push
Push
Be sure to remove the power plug
from the wall outlet.
4 Replace the Back Panel to the
main unit.
5Fill in the usage start date on the
Date Label.
Use the date as a guide for the filter re-
placement schedule.
Bottom Tabs
HEPA Filter
Deodorizing Filter
OM_FP-F40TA_TH-EN.indb 5 4/10/2558 BE 3:36 PM

E-6
OPERATION
AUTO SLEEP MED MAX
CLEAN AIR
START
• Select the desired fan speed.
• Unless the power cord has been unplugged,
the operation starts in the previous mode it
was operated in.
STOP
FAN SPEED
SLEEP
• The unit will operate very quietly, and the fan speed
is automatically switched depending on the amount of
impurities in the air.
DUST/PLASMACLUSTER SIGN go off automatically.
Even though the indicator is off, Plasmacluster Ion is
dispersed into air unless Plasmacluster Ion is turned off by
NOTE
AUTO
• The fan speed is automatically switched depending on the
amount of impurities in the air. The sensors detect impurities
for efcient air purcation.
Releases high-density Plasmacluster ions and discharges strong air ow for 60 minutes.
CLEAN ION SHOWER
START
• If Plasmacluster Ion is OFF, Plasmacluster Ion will not be
released.
• When the operation nishes, the unit will return to the prior
operation mode.
It is able to change the other mode and during this
mode.
NOTE
OM_FP-F40TA_TH-EN.indb 6 4/10/2558 BE 3:36 PM
Table of contents
Languages:
Other Sharp Air Cleaner manuals

Sharp
Sharp FU-40SE User manual

Sharp
Sharp FU-P60S User manual

Sharp
Sharp FP-J40E User manual

Sharp
Sharp FP-J52M User manual

Sharp
Sharp Plasmacluster FP-J80M User manual

Sharp
Sharp IG-DM1A Quick start guide

Sharp
Sharp FP-A80U User manual

Sharp
Sharp Plasmacluster IG-BL20E User manual

Sharp
Sharp KC-C70E User manual

Sharp
Sharp FP-JM30E User manual

Sharp
Sharp FU-W28E User manual

Sharp
Sharp FU-NC01 User manual

Sharp
Sharp FU-A28E User manual

Sharp
Sharp Plasmacluster FP-N60CX User manual

Sharp
Sharp KI-A60E User manual

Sharp
Sharp KI-AB60-W User manual

Sharp
Sharp FX-J80U Instruction Manual

Sharp
Sharp KC-G60E User manual

Sharp
Sharp KC-850EK User manual

Sharp
Sharp Plasmacluster KC-C100U User manual