Sharp FU-40SE-K User manual

R
FU-40SE-K
Tabletop / wall-mounting type
AIR PURIFIER
OPERATION MANUAL


FEATURES
Cluster Ion Control
The unit controls the ratio of minus cluster
ions and plus cluster ions depending on
the condition of the room.
•Clean mode
Approximately the same amount of plus
and minus cluster ions are discharged.
Thismodeiseffectiveforreducingfloating
mold and household odors in the air.
•Refresh mode
It is said that plenty of minus ions exist in
places such as waterfalls or forests.
In this operation mode, minus ions will be
released in an increased rate, in order to
bring the room air close to this condition.
•AUTO cluster ion mode
The unit will switch between the Clean
mode and Refresh mode automatically
depending on the amount of pollution in
the air detected by dust and odor sensor.
HEPA Filter
•High-efficiency dust collection
Stamina-power carbon
Powerful deodorization by large particles
of columnar charcoal.
CONTENTS
SAFETY PRECAUTIONS ........................ E-2
•CAUTIONS CONCERNING THE USAGE
OF THIS PRODUCT ....................................E-3
•CAUTIONS WHEN MOUNTING THIS
PRODUCT ON A WALL ...............................E-3
•CAUTIONS CONCERNING
THE INSTALLATION ....................................E-3
NAMES OF PARTS .................................E-4
•ACCESSORIES ...........................................E-5
INSTALLATION .......................................E-6
•
WHEN USING THE UNIT ON A TABLETOP ..
E-6
•WHEN WALL MOUNTING THE UNIT..........E-7
PREPARATION........................................ E-8
•INSTALLING THE FILTERS .........................E-8
•INSERTING BATTERIES
IN THE REMOTE CONTROL ......................E-8
•USING THE REMOTE CONTROL...............E-9
OPERATION .......................................... E-10
•MAIN UNIT OPERATION.......................... E-10
•REMOTE CONTROL OPERATION ...........E-11
CARE AND MAINTENANCE................. E-12
•MAIN UNIT................................................ E-12
•FILTERS.................................................... E-12
•GUIDE FOR LIFE OF FILTERS ................ E-13
TROUBLE SHOOTING.......................... E-14
SPECIFICATIONS ................................. E-14
ThankyouforpurchasingtheSHARPFU-40SE.
Pleaseread thismanualcarefully forthecorrect
usage.Beforeusingthisproduct,besure toread
“Safety precautions.”
After reading this manual, retain it in a conven-
ient location for future reference.
This product is for household use only.
E-1
FOR UNDERSTANDING
THE PRODUCT
Some of the odor ingredients
adsorbed by the filters become sepa-
rated and are discharged through the
exhaust port as odor.
Dependingontheusageenvironment,
this odour may become strong after
several months and the exhaust port
may smell.
In this case, purchase an exchange
filter FZ-40SEF of the option goods,
and replace the filters.
ENGLISH
Thisequipmentcomplieswiththe
requirements of Directives 89/
336/EEC and 73/23/EEC as
amended by 93/68/EEC.

•Do not use the unit if the power cord or plug is damaged or the connection to the wall
outlet is loose.
Electrical shock, short circuit and/or fire may occur as a result.
•Do not damage,break,coat,forcefully bend,pull, twist,bundle,pinch or place heavy objects
on the power cord.
If the power cord is damaged, fire and/or electrical shock may occur as a result.
•Use AC 220~240V only.
•Do not modify. Repair and disassembly of this product are to be performed by authorized
service personnel only.
Fire, electrical shock and/or bodily injury may occur if not.
For repair, contact your dealer or the nearest Sharp Service Center.
•Periodically remove dust from the power plug
Accumulated dust on the power plug may cause bad insulation from humidity, etc.
Fire and/or electrical shock may occur as a result.
•When cleaning the unit, be sure to remove the power plug from the wall outlet.
In addition, never handle the power plug with wet hands.
Electrical shock and/or bodily injury may occur as a result.
•Do not use the unit where there are oil ingredients such as cooking oil, etc., in the air.
Cracking of the unit surface may occur as a result.
•Do not wipe the unit with benzene or paint thinner. Also, do not spray insecticides on the
unit.
Cracking, electrical shock and/or fire may occur as a result.
•Do not operate the unit when using indoor smoke-generating insecticides.
Chemical ingredients may accumulate within the unit and then discharge from the exhaust port
when the unit operates. Discharge of such chemicals may be unhealthy to your body.
•Do not allow the unit to intake flammable gases, sparks from lit cigarettes, incense, etc.
The unit may ignite as a result.
•Do not use the unit where it is humid, such as in a bathroom, etc., or where the unit may
get wet.
Electrical shock and/or malfunction may occur as a result.
•Do not insert fingers or foreign objects into the intake or exhaust ports.
Electrical shock and/or malfunction may occur as a result.
•When mounting to a wall, select a sturdy wall or studding.
The unit may fall if not.
•When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or fire from short circuit may occur as a result.
•Ventilate when using the unit along with a heating appliance.
Carbon monoxide poisoning may occur as a result.
•Remove the power plug when not using the unit.
•If the supply cord is damaged,it must be replaced by the manufacturer or its service agent
or similarly qualified person in order to avoid a hazard.
•The batteries must be disposed of safely.
SAFETY PRECAUTIONS
E-2

CAUTIONS CONCERNINGTHE USAGE OFTHIS PRODUCT
• Do not block the intake and exhaust ports.
•Do not use the unit near or on hot objects, such as a stove, etc.Also, do not use the unit where it may
come into contact with steam.
•Do not use the unit on its side.
Deformation, malfunction and/or overheating of the motor may occur as a result.
•Do not install when there is generation of lampblack, such as in a kitchen, etc.
•Do not use detergent when cleaning the unit.
The unit surface may become damaged or cracked.
In addition, the sensors may malfunction as a result.
•When transporting the unit, always hold the handle on the back of the unit.
Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting in
bodily injury.
CAUTIONS WHEN MOUNTINGTHIS PRODUCT ON AWALL
•Never mount the unit to a thin wall or plasterboard of insufficient strength.The unit may fall as
a result.
•When mounting the unit to a wall, remove the front panel and hold the main unit.
Holding the front panel may cause it to become detached, thus dropping the unit and resulting in
bodily injury.
•Do not install when there is generation of lampblack, such as in a kitchen, etc.
The unit surface may crack or the sensors may malfunction as a result.
CAUTIONS CONCERNINGTHE INSTALLATION
DO NOT USETHE REMOTE CONTROL INTHE FOLLOWING LOCATIONS
•Locationswherethereare inverter lighting equipmentorelectronicspontaneouslightingequip-
ment
The remote control may become inoperative. In this case, move away from such lighting equipment
or change direction.
•Location exposed to direct sunlight
The unit may not received signals from the remote control
INSTALLATION
•Leave at least 2m of space from televisions and radios
Electrical interference may occur if not.
• Leave at least 60cm of space from the wall
The motor may overheat, causing malfunction if not.
•Avoid a location where sensors are exposed to direct wind
The unit may not operate properly.
•Avoid a location where curtains, etc., come into contact with the intake or exhaust port.
Curtains, etc., may become dirty or malfunction may occur as a result.
EFFECTIVE USAGE
•Place on a stable surface with sufficient air circulation
•Near smoking area
Air pollution is detected quickly.
ABOUTTHE FILTER
•Do not wash or reuse Apatite HEPA filter and deodorization filter.
•Small dust particles and odors such as tobacco smoke rise and accumulate at the top of the room.
•Large dust such as pollen and house dust accumulate at the bottom of the room.
•The wall, etc., behind the exhaust port may become dirty as time passes. When using the unit for
extensive period in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty.
In addition, periodically clean the wall, etc.
E-3

Plasmacluster
NAMES OF PARTS
MAINUNIT DISPLAY
Filter timer lamp
AUTO operation lamp
Fan level lamps
*
Tobacco smoke mode operation lamp
Pollen mode operation lamp
OFF timer display lamps
(set using remote control)
Power lamp
(Lights when the power plug is
inserted into the wall outlet)
Remote control receiver
Odor sensor
(Detects odors such as tobacco
smoke, incense, pets, cosmetics,
etc.)
Dust sensor
(Detects dust, smoke,
pollen, house dust, etc.)
Clean-sign lamp
The colour changes when the air is dirty
Clean (green) Little dirty (orange) Very dirty (red)
EXPLODED
DIAGRAM
MODE-ON/OFF button
(Usedtoselect operationsorturnthe
unit off)
Main unit
HEPA filter (white)
(Dust collection filter)
(W/ apatite antibacterial filter)
Stamina-power carbon (black)
(Deodorization filter)
Pre-filter
Front panel
Remote control
Hook
Stand
(Besuretomountfortabletopinstal-
lation)
Thumbscrew
ABOUT THE CLEAN-SIGN LAMP
•The dust sensor displays a clean sign depending on
the environment at the time the power plug is inserted
in the wall outlet.
•When the air is extremely dirty at the time the power
plug is inserted, the clean sign lamp may light green
since the polluted state is the environment which the
sensor bases the pollution rate on.
•Inthiscase,switchmanuallyto the desirableoperation
mode as effective operation can’t be done in auto
operation.
•To reset the base pollution rate of the clean-sign lamp
remove and insert the power plug.
E-4
Silent
Median
High Max
*It can not remove the noxious substances (carbon
monoxide etc.) from cigarette smoke.

ACCESSORIES
Remote control
(1 unit)
Battery
(AA battery X
2 units)
Whenusedonatabletop
Stand
(1 unit)
Thumbscrew
(2 units)
Located on
bottom of
stand
CLUSTER ION LAMP
Cluster ion operation is selected using the remote control.
Blue light
When the cluster ion operation is in the Clean mode or AUTO cluster ion mode and the
air in the room is dirty, the light turns on and the unit will operate in the Clean mode.
Green light
When the cluster ion operation is in the Refresh mode or AUTO cluster ion mode and
the air in the room is clean, the light turns on and the unit will operate in the Refresh
mode.
Light off
No cluster ions are generated.
If the lamp is to bright when sleeping, or if the ion generation noise is irritating, turn off
the cluster ion operation.
BACK
Handle
Exhaust port
Power cord
Power plug
Whenwallmounting this product
Wall mounting
bracket 1
Wall mounting
bracket 2
Wood screw
(4 units)
Small screw
(2 units)
Cushions
(2 units)
E-5

INSTALLATION
WHEN USING THE UNIT ON A
TABLETOP
FIXINGTHE STAND
1
Remove the front panel.
•At this time, also remove the pre-filter,
stamina-power carbon and the HEPA
filter.
Front panel
2
Place the unit with its front
side facing down on a flat
and stable surface.
•Place a soft cloth, etc., to prevent
damaging the unit.
3
Insert the tabs on the stand
into the holes on the main
unit and fix the stand using
the supplied thumbscrews
(2 units). Holes
WHENWALL MOUNTING
CAUTION
CAUTION
Mount on a flat sur-
face
•Do not mount the unit to
a thin wall with little
strength such as a plas-
terboard, etc. The unit
mayfalland can be very
dangerous.
•When mounting the air purifier on a wall, the
wall will become dirty as time passes.To pre-
vent this, place a vinyl sheet, etc., around the
unit.
•Ensure that the wall is suitable for mounting
the air purifier.
•Do not install in a location with heavy smoke,
suchasina kitchen, etc.The unit surfacemay
crack as a result.
1
Determinethe mounting location
Leavespacearoundthe bracket by referring
to the illustration below. The unit cannot be
mounted if there is insufficient spacing
around the bracket.
75cm or more 69cm or more from
the ceiling
Size of main
unit
75cm or more 75cm or more
Mounting
bracket 1
60cm or more from
sidewall 60cm or more
from sidewall
E-6
Thumb-
screws
Tabs
1
2
1

Mountthebracket to the backofthemain unit
using the small screws included.
3
Place the cushions as shown
4
Mount the main unit
(1) Align the horizontal positions of mounting
brackets 1 and 2 and hook the bracket 2 to
bracket 1.
(2) Hold the bottom
of the main unit,
pull the unit to-
wards you and
then pull down.
5
Check the installation
•Checktomake sure that the tabs on mount-
ing bracket 2 are securely mounted to the
tabs on mounting bracket 1.
•Check that the power cord is not pinched.
REMOVINGTHE UNIT
Pull the bottom of the unit towards you and then
lift.
NOTES
•When removing
the unit disconnect
the power cord.
Cushions (2 units)
E-7
2
Mount mounting bracket 2 to the
main unit
Mounting bracket 2
Small screws
(2 units)

PREPARATION Be sure to remove the power plug from the wall outlet.
INSTALLING THE FILTERS
To maintain the quality of the filters, they are installed in the main unit within polyvinyl bags.
Be sure to remove the filters from the polyvinyl bags before using the unit.
1
Remove the filters
1
Place the unit facing up
Place the unit on a table, etc., so that the
stand does not touch the surface.
2
Remove the front panel
Press in the hook on the bottom of the front
panel and lift to remove.
3
Remove the pre-filter, and
then remove the stamina-
power carbon (black) and
HEPA filter (white) that are
inside the polyvinyl bags.
INSERTING BATTERIES IN THE REMOTE CONTROL
1
Remove the
back cover
Press and slide the
back cover to re-
move.
2
Insert batteries
Insert batteries with
and as shown
below.
3
Close the back
cover
About the batteries
• The battery life is about 1 year.
Replacethebatterieswhentheremote con-
trol becomes inoperative.
•Incorrectusageof thebatteries maycause
battery fluid leakage and/or damage.Take
caution of the following when handling:
•When replacing the batteries, replace
bothbatterieswith newones ofthe same
type.(Use AA alkaline batteries (2 units)
or AA manganese batteries (2 units).)
•When not using the unit or remote con-
trol for an extensive period, remove the
batteries.Thispreventsmalfunctionof the
remotecontrol frombatteryfluid leakage.
Soft cloth
Prefilter
Table, etc.
Front panel
1
1
2
2
1
Place so stand
does not touch
the surface
Hook
Stamina-power carbon
E-8

2
Install the filter
1
Remove the HEPA filter from
the polyvinyl bag and install it
in the main unit with the
display facing up.
Insert so that the tabs on the HEPA filter
are facing you.
Proper operation cannot be achieved if
installed incorrectly.
USING THE REMOTE CONTROL
HEPA filter
Tabs
2
Removethe stamina-powercar-
bon from the polyvinyl bag and
install it in the main unit.
Make sure the tabs on the HEPA filter remain vis-
ible.
Stamina-power carbon
3
Install the pre-filter
Insert the 4 tabs on the pre-filter in the holes of the
main unit.
4
Fill in the usage start date on
thereplacement labelaffixedon
the back of the front panel and
then mount the front panel.
Use the date as a guide for the filter replacement
period.
Back of front panel
Replacement label
•Operate the remote control facing the main unit (re-
ceiver).
•The signal range is about 7m (front).
•Make sure there are no objects blocking the path of the
signal.
•ABeep will be heard from the main unit when a signal is
received.
Receiver Transmitter
NOTE
•Avoid strong impact on the remote control. In addition,
do not wet the remote control or place it under direct
sunlight or near a stove, etc.Malfunction may occur.
E-9

OPERATION
MAIN UNIT OPERATION
The unit will start operation when the MODE-ON/OFF button is pressed.
(The unit will start operation in AUTO mode)
•During operation, the cluster ion lamp will light.
(During start of operation, the cluster ion mode will be AUTO)
The operation mode suitable for the usage condition can be set.
Stop
AUTO operation
The fan level is automatically switched (High, Median, Silent) depend-
ing on the amount of pollution in the air detected by the dust sensor for
efficient air purification.
Silent operation
The unit will operate using little air.
Median ~ Max operation
The unit will operate with fan level of median, high or max.
*Tobacco smoke mode operation
The unit will operate in High for 10 minutes, then the unit will return to
the AUTO mode.
10 minutes: High fan level
AUTO mode operation
Pollen mode operation
Theunit will operate in Highfor10minutes,thenthe unit will alternately
operate between Median and High.
10 minutes: High fan level
20 minutes: Median level
20 minutes: High fan level
For the first 30 seconds after the powerplugisinserted
into the wall outlet, the unit will check the conditions of
the air. If operation is set to ON during this time, the
Clean sign lamp will alternately flash in green, orange
and red.During this time, the Cluster ion lamp will light
blue and the unit will be in the Clean mode.
Cluster ion lamp
•AUTO operation
•Silent operation
•Median level operation
•High level operation
•Max level operation
•*Tobacco smoke mode
operation
•Pollen mode operation
Operations available with
main unit
E-10
Plasmacluster
*It can not remove the noxious
substances(carbonmonoxide
etc.) from cigarette smoke.
MODE-ON/OFF button

REMOTE CONTROL
OPERATION
•To start operation, press the ON/OFF button.
A short beep will sound and operation will start in the
AUTO mode.
•To stop operation, press the ON/OFF button again.
A long beep will sound and operation will stop.
Transmitter
Manual (fan level)
button
The fan level can be switched
between Silent, Median, High
and Max.
Silent operation but-
ton
Operation will be in the Silent
mode with little air.
*Tobacco smoke
mode operation but-
ton
Unit will operate effectively
when smoking cigarettes, etc.
ON/OFF button
Used to start AUTO operation
(short beep) and stop opera-
tion (long beep).
Filter reset button
Press this button after replac-
ing the filters.
AUTO (fan level) but-
ton
The fan speed depends upon
the amount of pollution in the
air.
Max operation button
Used to quickly clean the air in
the room.
Pollen mode opera-
tion button
The unit operates effectively
when you suspect pollen in the
air.
OFF timer button
Used to set the OFF timer.
The set time switches every
time the button is pressed as
shown below.
1 hour
4 hours
8 hours
Cancel
•The remaining time is indi-
cated by the lamp as time
passes.
•The unit will stop operation
when the timer is up.
Cluster ion select button
AUTO cluster ion button
Theunit willswitchbetween theClean modeand
Refresh mode automatically depending on the
amountof pollutionin theair detectedbythe dust
and odour sensor.
Clean button
The unit will constantly operate in the Clean
mode.The Clean mode is effective for removing
mold fungus in the air.
(Cluster ion lamp on (blue))
OFF button
The generation of ions is stopped and the
cluster ion lamp is turned off.
Refresh button
The unit will constantly operate in the Re-
fresh mode.The Refresh mode maintains
the balance of ions in the air for a refresh-
ing effect.
(Cluster ion lamp on (green))
If the room smells especially moldy, operate the unit in the Clean mode.
•Fan level manual opera-
tion
•Fan level AUTO operation
•Silent operation
•Max operation
•*Tobacco smoke mode
operation
•Pollen mode operation
•OFF timer setting
•Cluster ion select
AUTO cluster ion
Clean mode
Refresh mode
Operations available with
remote control
E-11
At the start of operation, the
Cluster ion mode is also set
to AUTO.
RESET
AUTO OFF
AIR PURIFIER
Plasmacluster
*It can not remove the noxious
substances (carbon monoxide
etc.) from cigarette smoke.

CARE AND MAINTENANCE
(To maintain the best performance of this product, please clean the unit periodically.)
When cleaning, be sure to remove the power plug from the wall outlet. In addition, never
handle the power plug with wet hands.
Electrical shock and/or bodily injury may occur as a result.
MAIN UNIT
For soiling on the main unit and the installed
surface, clean as early as possible. Stubborn
dirt may be hard to remove.
Dry wipe with a soft cloth
For stubborn dirt, wipe with a soft cloth damp-
enedwithwaterorwarm water of40°Corless.
Do not use volatile fluids
Benzene,paintthinner, polishing powder, etc.,
may damage the unit surface.
Do not use detergents
Detergent ingredients may damage the unit
surface.
Do not get wet
Never apply water on the unit.
ODOR SENSOR
DUST SENSOR
The sensitivity of the sensors will become
unstable if the odor or dust sensor is dirty or
blocked.
Remove dust on the surfaces of the sensor
openings using a vacuum cleaner.
FILTERS
Clean using the nozzle of a vacuum
cleaner without removing the pre-filter.
NOTE
Never wash or clean the HEPA filter or
stamina-power carbon by directly con-
tacting the nozzle of a vacuum cleaner.
This will greatly decrease the perform-
ance of the filters.
Odor sensor Dust sensor
E-12

Guide for filter replacing timing
•The following is a guide from JEM 1467 by Japan Electrical Manufacturers Association in
Japan,and in JEM 1467, thereplacementperiodissetas when smoking 10 cigarettes per
day and the dust collection/deodorization power is reduced by half that of new filters.
•HEPA filter About 5 years after opening
•Stamina-power carbon About 5 years after opening
•The filter timer lamp is programmed to light in about 5 years, when using the unit for 12
hours everyday, in order to indicate accumulated usage time of the guide above.
•The filter timer lamp is to be used only as a guide.
•The operation hours are kept in memory even when removing the power plug for
transportation to another room, etc.
GUIDE FOR LIFE OF FILTERS
•The replacement period differs depending on the usage hours and
location of installation.
•Some of the odor ingredients adsorbed by the filters become separated
and are discharged through the exhaust port as odor.
Depending on the usage environment, this odor may become strong in
several months and the exhaust port may smell.
If dust or odors cannot be removed easily, replace the filters.
(Refer to page1, FOR UNDERSTANDING THE PRODUCT)
REPLACING THE FILTERS
1
See page 8 “Installing the filters” for the replacement method.
2
After replacing the filters:
Be sure to press the Reset button on the remote control with the power plug inserted in
the wall outlet.
A short beep will be heard and the operation hours stored in the memory will be reset. If
the filter replacement lamp is on, the lamp will turn off.
3
Fill in the usage start date of the filters on the date label in-
cluded with the replacement filters. Affix the label on top of the
replacement label that is already on the back of the front panel.
Replacement filters
•HEPA filter: 1 unit
•Stamina-power carbon: 1 unit
Model: FZ-40SEF
Please ask for replacement filters at your dealer of purchase.
Cautions concerning the disposal of filters
Please dispose of replaced filters according to the local disposal laws and regulations.
HEPA filter materials:
•Filter: Polypropylene
•Frame: Polyester
Stamina-power carbon materials:
•Deodorizer: Activated charcoal
•Frame: Polyester
E-13

TROUBLESHOOTING
Before calling for repair, check the symptoms below for possible remedies, since the problem may
not be a malfunction of the unit.
SYMPTOM REMEDY (not a malfunction)
The remote control does not
work •Have the batteries depleted?
•Are the batteries inserted correctly?
•Is a fluorescent lighting in the room flickering due to service
life? (Refer to E-3)
Odors and smoke cannot be re-
moved easily •Are the filters heavily soiled? (Refer to E-13)
The Clean sign lights green
even when the air is dirty •Is the opening of the dust sensor blocked or clogged?
•Was the air already dirty when the power plug was inserted
into the wall outlet? (Refer to E-4)
The Clean sign lights orange or
red even when the air is clean •The sensitivity of the sensor becomes unstable when the
opening of the dust sensor is dirty or is clogged.
Clean the dust around the sensor opening using a vacuum
cleaner.(Refer to E-12)
The cluster ion lamp remains
green (blue) and does not
change
•DuringtheCleanmode (orRefresh mode),the clusterion lamp
colour will not change.
A sound is
heardfromthe
unit
Click, click
Tick, tick, tick
•This is the sound that is emitted when the unit is in t h e
Refresh mode.
If the sound is irritating, switch the unit to the Clean mode.
•This is the sound that is emitted when the unit is generating
cluster ions.
If the sound is irritating, such as when sleeping, etc., set the
Cluster ion mode to OFF.
The discharged air smells •The ozone generated by the cluster ion generator may have
an odor.However, the density of ozone generated is very little
and is harmless to the human body. Furthermore, the ozone
decomposes quickly so it does not accumulate in the room.
The unit does not operate even
when smoking cigarettes •Is the unit installed in a location that is difficult for the sensors
to detect cigarette smoke?
•Are the odour and dust or dust sensor openings blocked or
clogged? (In this case, clean the openings.)
(Refer to E-12)
SPECIFICATIONS The applicable floor surface area is the surface area for
when operating the unit in Max fan level.
(According to Japan Electrical Manufacturers’ Association
JEM1467)
Power supply 220V-240V 50Hz
Fan level
operation
Fan level adjustment Max High Median Silent
Rated power 39W 21W 10W 4W
Fan level 240m3/hour 180m3/hour 117m3/hour 30m3/hour
Applicable floor surface ~31m2
Cord length 2.5m
Dimensions 415mm(W)X197mm(D)X572mm(H)(W/ stand)
Weight 6.6kg
About the reduction of standby power
In order to operate the electrical circuits while the power plug is inserted in the wall outlet, this product
consumes about 0.8W of standby power.
(At this time, the power lamp will be on) For the conservation of energy, remove the power plug when
not using the unit
E-14
SHARP CORPORATION
OSAKA, JAPAN
TINS-A056KKRZ 02HK 1
Table of contents
Other Sharp Air Cleaner manuals

Sharp
Sharp FU-Z31E User manual

Sharp
Sharp Plasmacluster KC-30TX1 User manual

Sharp
Sharp FP-JM30E User manual

Sharp
Sharp FP-K50UW User manual

Sharp
Sharp EH-HS41 User manual

Sharp
Sharp KI-L60TA User manual

Sharp
Sharp FU-21SE User manual

Sharp
Sharp FP-J30M User manual

Sharp
Sharp FU-40SE-TA User manual

Sharp
Sharp FX-J80J-W User manual

Sharp
Sharp FU-A80A User manual

Sharp
Sharp IG-NX2B User manual

Sharp
Sharp FU-440E User manual

Sharp
Sharp IG-EX20B User manual

Sharp
Sharp FP-J80E User manual

Sharp
Sharp UA-KIL80E User manual

Sharp
Sharp FZ-40SEF User manual

Sharp
Sharp UA-KIN40E-W User manual

Sharp
Sharp Plasmacluster IG-A20E User manual

Sharp
Sharp FP-R30CX User manual