Sharp FX-J80A User manual

AIR PURIFIER
OPERATION MANUAL
* The number in this technology mark indicates an
approximate number of ions supplied into air of 1
cm3, which is measured around the center of a room
applicable oor area (at 1.2 m height above the oor)
when the product is placed close to a wall at the MED
mode setting.
FX-J80A
“Plasmacluster” and “Device of a cluster of grapes” are
trademarks of Sharp Corporation.
空氣清新機
使用說明書
ENGLISH
中文
* The number in this technology mark indicates an
approximate number of ions supplied into air of 1
cm3, which is measured around the center of a room
applicable oor area (at 1.2 m height above the oor)
when the product is placed close to a wall at the MED
mode setting.
FX-J80A_EN_090118.indd 1 10/5/2561 BE 10:39 AM

The air purier draws in room air through
the air intake, circulates it through a Pre-
Filter, an Active Carbon Deodorizing Filter
and a HEPA Filter inside the main unit, and
then discharges it through the air outlet.
The HEPA Filter can remove 99.97% of
dust particles as small as 0.3 microns that
pass through the lter and also absorb
odors. The Active Carbon Deodorizing
Filter gradually absorbs odors as they pass
through the lter.
Some odors absorbed by the lters will break down over time, causing additional odors.
Depending on usage conditions, and especially if the main unit is used in environments
signicantly more severe than a normal household, these odors may become noticeable sooner
than expected. If these odors persist, the lters should be replaced. (page 10)
NOTE
• The air purier is designed to remove air-suspended dust and the odors.
The air purier is not designed to remove harmful gases such as carbon monoxide contained in cigarette smoke.
The air purier may not completely remove an odor if the source of the odor is still present.
CONTENTS
IMPORTANT SAFETY INSTRUCTIONS
........2
PARTS NAME ..........................................4
FILTER INSTALLATION ..........................6
OPERATION
START/STOP........................................7
AUTO MODE ........................................7
CLEAN ION SHOWER MODE..............7
PLASMACLUSTER ION SPOT MODE
.......7
FAN SPEED..........................................7
ON TIMER.............................................8
OFF TIMER...........................................8
CHILD LOCK.........................................8
PLASMACLUSTER ION ON/OFF.........8
MODE SETTING
.........................................
9
Light Control / Auto Restart / Adjustment of
sensor detection sensitivity
CARE AND MAINTENANCE /
REPLACEMENT
HEPA FILTER / ACTIVE CARBON
DEODORIZING FILTER........................10
MAIN UNIT / PRE-FILTER (BACK PANEL)
.....11
PLASMACLUSTER ION GENERATING UNIT
..11
TROUBLESHOOTING.............................12
SPECIFICATIONS....................................13
Thank you for purchasing this SHARP Air Purier.
Please read this manual carefully before using the product.
This manual should be kept in a safe place for handy reference.
Please read before operating your new Air Purier
Pre-Filter
Active Carbon
Deodorizing Filter
HEPA Filter
ENGLISH
FX-J80A_EN_090118.indd 2 10/5/2561 BE 1:16 PM

EN-1
Thank you for purchasing this SHARP Air Purier.
Please read this manual carefully before using the product.
This manual should be kept in a safe place for handy reference.
A unique Combination of Air Treatment Technologies
Triple Filteration System + Plasmacluster
High Density Plasmacluster 25000
The higher the PCI density is, the more effective PCI has.
Triple Filteration System
TRAP DUST
Pre-Filter traps dust larger than approx 240 micron particles.
DECREASES ODORS
Active Carbon Deodorizing Filter absorbs many common household odors.
REDUCES TINY DUST, POLLEN & MOLD
HEPA Filter traps 99.97% of particles as small as 0.3 microns.
Unique Airow
Powerful air suction and unique airow quickly and efciently collect dust and other particles.
Faster airow at a 20º angle collects dust at
lower levels in the room for more effective
cleaning.
Plasmacluster can remove static electricity
and can thus prevent dust from attaching to
walls and other surfaces.
Plasmacluster
By emitting a balance of positive and negative ions, Plasmacluster air treatment is a natural process.
PM2.5 Monitor
• Inform by lighting PM2.5 monitor when Sensitive Dust sensor detects microscopic dust.
• Display the value of PM2.5 in 3 digits.
Plasmacluster Ion Spot Mode
• Recommended when odor and germs adhering to sofa and curtains are concerned.
• Emits highdensity Plasmacluster Ions only in the forward directions.
ENGLISH
FX-J80A_EN_090118.indd 1 10/5/2561 BE 10:39 AM

EN-2
IMPORTANT SAFETY INSTRUCTIONS
Always follow basic safety precautions
when using electrical appliances,
including the following:
WARNING – Always observe the
following to reduce the risk of electrical
shock, re, or injury:
• Read all instructions before using the
main unit.
• Use only a 220 volt outlet.
• This appliance is not intended for use
by persons (including children) with
reduced physical, sensory or mental
capabilities, or lack of experience
and knowledge, unless they have
been given supervision or instruction
concerning use of the appliance by a
person responsible for their safety.
Children should be supervised to
ensure they do not play with the
appliance.
• If the power cord is damaged, it must
be replaced by the manufacturer, its
service agent, a Sharp authorized
Service Center or similarly qualied
persons in order to avoid a hazard.
Contact the nearest Service Center
for any problems, adjustments, or
repairs.
• Be sure to remove the power plug,
before performing maintenance, when
removing and attaching and replacing
the lter and when not using for a
long time. Failure to do so can cause
a short circuit resulting in electrical
shock or re.
• Do not use the main unit if the power
cord or plug is damaged or if the
connection to the wall outlet is loose.
• Periodically remove dust from the plug.
• Do not insert ngers or foreign objects
into the air intake or air outlet.
• When removing the power plug, always
hold the plug and never pull on the cord.
Failure to do so can cause a short circuit
resulting in electrical shock or re.
• Be careful not to damage the power
cord, it may cause electric shock, excess
heat or res.
• Do not remove the plug when your hands
are wet.
• Do not place the main unit near or on
hot objects, such as stoves or heaters,
or where it may come into contact with
steam.
• Do not operate the main unit in rooms
where aerosol insecticides are present.
Do not operate the main unit in rooms
where there is oily residue, incense,
sparks from lit cigarettes, or chemical
fumes in the air. Do not operate the main
unit in places where it may get wet, such
as a bathroom.
• Be cautious when cleaning the main unit.
Strong corrosive cleansers can damage
the exterior.
• Do not expose the main unit to water.
Doing so can cause a short circuit or
electrical shock.
NOTE – What to do if the main unit
interferes with radio or TV reception
If the air purier interferes with radio or
television reception, try one or more of the
following measures:
• Adjust or reposition the receiving
antenna.
• Increase the distance between the main
unit and the radio or TV.
• Connect the equipment into an outlet on
a circuit different from that of the radio or
TV receiver.
• Consult the dealer or a qualied radio or
TV technician.
FX-J80A_EN_090118.indd 2 10/5/2561 BE 10:39 AM

EN-3
CAUTIONS CONCERNING
OPERATION
• Do not block the air intake or air outlet.
• Always operate the main unit in an
upright position.
• Do not move the main unit when it is in
operation.
• When moving the main unit, use the
handles on both sides.
• If the main unit is on easily damaged
ooring, an uneven surface, or thick-
piled carpet, lift it up when moving.
• Do not operate the main unit without the
lters properly installed.
• Do not wash and reuse the HEPA lter
and the Active Carbon Deodorizing lter.
Doing so will not improve lter
performance and can also cause electric
shock or operating malfunctions.
• Clean the exterior with a soft cloth only.
Do not use volatile uids or detergents.
The main unit surface may be damaged
or cracked with Benzine, paint thinner
or polishing powder. In addition, the
sensors may malfunction as a result.
• Keep the main unit away from water.
• Do not scrub the Back Panel hard during
its maintenance.
INSTALLATION GUIDELINES
• Avoid locations where the sensors are
exposed to direct wind.
Doing so can cause the main unit to
malfunction.
• Avoid locations where furniture, fabrics,
or other objects can come in contact with
the main unit and interfere with the intake
and outtake of air.
• Avoid locations where the main unit
is exposed to condensation or drastic
changes in temperature. Appropriate
room temperature is between 0 – 35 ºC.
• Place the main unit on a level and stable
surface with sufcient air circulation.
When placed on heavy carpet, the main
unit may vibrate slightly.
• Avoid locations that generate grease or
oily smoke.
Doing so can cause the main unit
exterior to crack and the sensors to
malfunction.
• The dust collecting ability of the main
unit is effective even when the main unit
is as close to 3 cm from the wall,the
surrounding walls and oor may get dirty.
Please place the main unit at a distance
from the wall.
The wall directly behind the air outlet
may become dirty over time. When using
the main unit for an extended period of
time at the same location, periodically
clean the walls adjacent to it.
FILTER GUIDELINES
• Follow the instructions in this manual for
proper lter care and maintenance.
(page 10)
ENGLISH
FX-J80A_EN_090118.indd 3 10/5/2561 BE 10:39 AM

EN-4
PARTS NAME
MAIN UNIT
(FRONT)
(BACK)
1. Operation Panel
2. Air Outlet (Front/Back)
3. Cleanliness Monitor
4. Front Display
5. Main Unit
6. Handle (2 Locations)
7. Front Louver
8. Pre-Filter (Back Panel)
9. Air Inlet
10. Active Carbon Deodorizing Filter
11. HEPA Filter
12. Sensor Filter/
Odor and Sensitive Dust Sensor
13. Plasmacluster Ion Generating Unit
14. Unit Holder
15. Unit Cover
16. Unit Cleaning Brush
17. Power Cord, Plug
1 2
3
4
5
6
7
11
13
10
8
9
1514
12
16
17
FX-J80A_EN_090118.indd 4 10/5/2561 BE 10:39 AM

EN-5
1. Power ON/OFF Button
2. AUTO Button, Indicator Light
3. CLEAN ION SHOWER Button,
Indicator Light
4. Plasmacluster Ion SPOT Button,
Indicator Light
5. MODE Button, Indicator Light
6. Timer Button
(Touch 3 sec.) FILTER RESET Button
7. (Touch 3 sec.) CHILD-LOCK Button
8. Child-Lock Indicator Light
9. Light Sensor
10. PM2.5 Indicator Light
Indicates the Sensitive Dust Sensor detects
microscopic dust.
TURN OFF
Orange Red
Clean Impure
11. Dust Indicator Light
Indicates the Sensitive Dust Sensor detects usual
dust.
TURN OFF
Orange Red
Clean Impure
FRONT DISPLAY
OPERATION PANEL Touch the button with " " to start.
12. Odor Indicator Light
Indicates the Odor Sensor detects odors.
TURN OFF
Orange Red
Clean Impure
13. Unit Replacement Indicator Light
14. Filter Maintenance Indicator Light
15. ON Timer Indicator Light
16. OFF Timer Indicator Light
17. Plasmacluster Ion Indicator Light
18. DISPLAY
• PM2.5 Monitor
PM2.5 Density 10μg/m3 to 499μg/m3is displayed.
500μg/m3
or more
9μg/m3
or less
• Timer Monitor
Indicates setting time or remaining time of ON/OFF timer.
19. Cleanliness Monitor
Indicates the air purity of the room in 3 levels with color changes.
Blue Yellow Red
Clean Impure
1234567
8
9
17 18161514
19
13121110
ENGLISH
FX-J80A_EN_090118.indd 5 10/5/2561 BE 10:39 AM

EN-6
1. Remove the Pre-Filter (Back Panel).
2. Remove the plastic bag from the lter.
3. Install the lters in the correct order as shown.
4. Install the Pre-Filter (Back Panel).
NOTE
• When replacing the lter, making a memo of the start of use date is recommended.
HEPA FILTER / ACTIVE CARBON DEODORIZING FILTER
FILTER INSTALLATION
Always be sure to remove the
power plug from the wall outlet.
HEPA Filter Tag
Pre-Filter (Back Panel)
HEPA Filter
Active Carbon
Deodorizing Filter
Click
Active Carbon
Deodorizing Filter
1
2
FX-J80A_EN_090118.indd 6 10/5/2561 BE 10:39 AM

EN-7
PLASMACLUSTER ION
SPOT MODE
START/STOP
AUTO MODE
CLEAN ION SHOWER
MODE
FAN SPEED
SLEEP :
The main unit will operate quietly, and the fan speed
is automatically switched depending on the amount
of impurities in the air
and room brightness
.
The Front Display and Cleanliness Monitor
automatically switches darker or OFF based on
room brightness.
Room is bright: light is darker
Room is dark: light is OFF
POLLEN :
The DUST SENSOR sensitivity is automatically
increased and quickly detects impurities such as
dust and pollen and clean the air powerfully.
START STOP
OPERATION
♪
♪
♪
The fan speed is automatically controlled
depending on the 3 detection. (Sensitive Dust / Odor /
Light)
NOTE
• Front Display, Cleanliness Monitor automatically
switch ON and Darker based on room brightness.
(When light control is set to "Auto". (page 9))
Use this mode when you want to remove adhering
odor, germs, and other substances from cloths,
sofas and curtains.
Adjust Front Louver manually.
NOTE
• Emits high density Plasmacluster Ions only in the
forward direction.
• Discharges stronger air for 8 hours. When the
operation nishes, the main unit will return to its
prior operation mode.
• The Plasmacluster Ion can not be turned “OFF”.
The main unit releases Plasmacluster ions with
strong airow and collects dusts while decreasing
static electricity for 10 minutes. After that, the
DUST sensor sensitivity is automatically increased
and quickly detects impurities and clean the air
powerfully for 50 minutes.
NOTE
• When the operation nishes after 60 minutes,
the unit will return to the prior operation mode.
It is able to change the other mode during this
mode.
• The Plasmacluster Ion can not be turned “OFF”.
♪
♪
♪
♪
♪♪
POLLEN
SLEEP
LOW
MED
HIGH
♪
♪
♪
♪
♪
♪
♪
♪
♪
ENGLISH
FX-J80A_EN_090118.indd 7 10/5/2561 BE 10:39 AM

EN-8
CHILD LOCK
PLASMACLUSTER ION ON/OFF
The operation panel will be locked.
When the Plasmacluster function is ON, the
Plasmacluster Ion Indicator light is on. (page 5)
(In operation)
♪♪♪
ON
ON
CANCELLATION
OFF
Select the length of time you want.
The Main Unit automatically starts once the
selected time is passes.
Select the length of time you want.
The Main Unit automatically stops once the selected
time is reached.
ON TIMER
OFF TIMER
(with the Main Unit OFF)
(In operation)
Front Display
Front Display
……
♪ ♪ ♪ ♪ ♪♪
1hour 2hour 3hour 12hour Cancel
……
♪ ♪ ♪ ♪ ♪♪
1hour 2hour 3hour 12hour Cancel
♪
more than 3 sec.
more than 3 sec.
♪♪
more than 3 sec.
more than 3 sec.
♪
♪
• After 8 seconds, the beep sounds.
• After 8 seconds, the beep sounds.
FX-J80A_EN_090118.indd 8 10/5/2561 BE 10:39 AM

EN-9
MODE SETTINGS
You can change the functions in the table "Type of setting" below.
Function Setting
Light Control
You can select the brightness of the Front Display
and Cleanliness Monitor.
Turn off
Darker
Auto (default)
Light automatically switches based on room brightness.
Room
brightness
Front Display and
Cleanliness Monitor
ALL MODE
(Except SLEEP)
SLEEP
MODE
Bright ON Darker
Dark Darker Turn off
Auto Restart
If the Main Unit is unplugged or if there is a power
failure, the Main Unit will resume operation with the
previous settings after power is restored.
Cancel (default)
ON
Adjustment of Sensor Detection Sensitivity (F3-F5)
Light Sensor Low
Sensitive Dust Sensor Standard (default)
Odor Sensor High
1. Turn the Main Unit power OFF.
2.
more than 3 sec.
♪
3. Select "Function number".
Reverse Forward
or
・・・・
Set ♪
♪♪
4. Select "Setting number".
Reverse Forward
or
Set ♪~
5. Touch Power ON/OFF Button to
nish the setting.
♪~
Turn off
♪♪
ENGLISH
FX-J80A_EN_090118.indd 9 10/5/2561 BE 10:39 AM

EN-10
HEPA FILTER / ACTIVE CARBON DEODORIZING FILTER
CARE AND MAINTENANCE / REPLACEMENT
FILTER MAINTENANCE
Remove the dust on the lters.
CAUTION
Do not wash the lters. Do not expose to sunlight.
(Otherwise these lters may lose efcacy.)
HEPA FILTER
Maintain only the tagged
surface. Do not clean up
the opposite surface.
The lter is fragile, so be
careful not to apply too
much pressure.
ACTIVE CARBON
DEODORIZING
FILTER
Both surfaces can be
maintained.
The lter may be broken if
being too much power is
applied on it, so please handle it with care.
Some odors absorbed by the lters will break down over
time, causing additional odors. Depending on usage
conditions, and especially if the Main Unit is used in
environments signicantly more severe than a normal
household, these odors may become noticeable sooner
than expected.
Replace the lter in those cases or if dust is unable to be
removed after maintenance.
Tag
LIFE OF FILTERS
Filter life varies depending on the room environment,
usage conditions, and location of the Main Unit.
Lifespan of HEPA lter and Active Carbon
Deodorizing lter and replacement suggestions are
based on purifying a room in which 5 cigarettes are
smoked per day and the Main Unit's dust collection
and deodorizing performance has declined to half
the level of a new lter.
We recommend replacing the lter more frequently if
the Main Unit is used in conditions signicantly more
severe (PM2.5 etc.,) than a normal household.
HEPA Filter :
About 10 years after opening
Active Carbon Deodorizing Filter :
About 10 years after opening
Replacement Filter Model
Consult your dealer when purchasing a replacement
lter.
HEPA Filter(1 unit) Active Carbon
Deodorizing Filter(1 unit)
FZ-J80HFE FZ-J80DFE
Disposing of lters
Dispose of used lters according to local laws and
regulations.
HEPA Filter material:
• Polypropylene • Polyethylene
Active Carbon Deodorizing Filter material:
• Polypropylene • Polyester
• Activated carbon
FILTER MAINTENANCE INDICATOR
The lter maintenance Indicator Light
will turn on after approximately
720 hours operating.
This is a reminder to perform the
maintenance described below.
After performing maintenance,
reset the Filter Indicator.
RESET
more than 3 sec.
FX-J80A_EN_090118.indd 10 10/5/2561 BE 10:39 AM

EN-11
1.
Remove the unit cover,
and pull out the unit
holder.
2.
Remove dusts from the
electrode section.
3.
Insert the unit holder
in the Main Unit, and
install the unit cover.
CAUTION
• Do not clean with other unit cleaning brush. Doing so could lead to failures in the unit.
• A bent electrode could be cut off and dropped during the cleaning process, but it will not change the performance.
• Do not touch the electrode directly. Doing so could lead to pain/itching.
• Do not transform the electrode section. Doing so can damage it.
• Do not touch the connection terminals. Doing so can damage them.
NOTE How to clean hard to remove dirt.
Pre-Filter
1.Add a small amount of neutral detergent
to water and soak about 10 minutes.
CAUTION
Do not apply excessive pressure when
scrubbing the pre-lter.
2. Rinse off the neutral detergent pre-lter with clean water.
3.Completely dry the lter in a wellventilated area.
Sensor Filter
1.Remove the Pre-Filter.
2. Remove the sensor lter.
3. If the sensor lter is very dirty, wash it
with water and dry it thoroughly.
Plasmacluster Ion Generating Unit (electrode section)
Wipe with a dry, soft cloth
Remove the dust gently with a cleaning
tool such as a vacuum cleaner.
MAIN UNIT / PRE-FILTER (BACK PANEL)
Sensor
Filter
Unit Cleaning Brush
Electrode Around the base
Before cleaning After
cleaning
Pre-Filter
(Back Panel)
Remove the claw of unit holder ( ),
and remove the Plasmacluster Ion
Generating Unit ( ).
1
2
UNIT REPLACEMENT INDICATOR
When the total operation time exceeds 17,500
hours, the Unit Replacement indicator will ash
to indicate that the Plasmacluster Ion Generating
Unit needs replacement.
Operating time
17,500 hours
Flash slowly
Replace the Plasmacluster
Ion Generating Unit
19,000 hours
Flash quickly
Stop the emission of the
Plasmacluster ions.
* The replacement time is not related to the selected
operation mode.
Replacement Plasmacluster Ion Generating Unit Model
Consult your dealer when purchasing a replacement
Plasmacluster Ion Generating Unit.
IZ-PF10XP-HK
1
2
1
2
Disposing of Plasmacluster Ion Generating Unit
Dispose of used Plasmacluster Ion Generating Unit
according to local laws and regulations.
material: • Polystyrene terephthalate • electronic parts
ENGLISH
FX-J80A_EN_090118.indd 11 10/5/2561 BE 10:39 AM

EN-12
TROUBLESHOOTING
Odor and smoke persists.
• Check the lters. If they appear to be extremely
dirty, clean or replace them.
The Cleanliness Monitor is blue
even when the air is not clean.
• The air may have been dirty when the main unit
was plugged in. Unplug the main unit, wait one
minute, and then plug the main unit in again.
The Cleanliness Monitor light is
red even when the air is clean.
• Dirty or clogged sensitive dust sensor openings
interfere with sensor operation. Gently clean the
sensor lter or the back panel.
The Main Unit makes a clicking or
ticking sound.
• The main unit may make clicking or ticking
sounds when it is generating ions.
Air discharged from the Main Unit
has an odor.
• Check to see if the lters are extremely dirty.
• Clean or replace the lters.
The Main Unit does not operate
when cigarette smoke is in the air.
• Make sure the Main Unit is installed in a location
in which the sensors can detect cigarette smoke.
• Check to see if the sensitive dust sensor openings
are blocked or clogged. If they are blocked or
clogged, clean the sensor lter or the back panel.
The FILTER Maintenance Indicator
Light is on.
• Whenever after performing maintenance of the
lters, connect the power cord to an outlet and
then touch the Filter Reset Button. (page 10)
The Front Display is turned off.
• When Light control is set to "Turn off", the light
is always off. If you do not want the light to be
off, set Light control to “Auto” or "Darker" setting.
(page 9)
The Cleanliness Monitor changes
color frequently.
• The Cleanliness Monitor automatically changes
color when the sensitive dust sensor and odor
sensor* detect impurities. If you are concerned
about the change, you can change sensor
sensitivity. (page 9)
The Main Unit’s Display does not
match weather report.
• Outdoor and indoor as well as the home
environment (the volume of trafc nearby, number
of stories in home, etc.) may cause a reading
different than those data.
ERROR DISPLAY
If error occurs repeatedly, contact the Sharp
Service Center.
• The concentration of
Plasmacluster ion is descending.
⇒Maintain the Plasmacluster
Ion Generating Unit (electrode
section).
• Is the the Plasmacluster Ion
Generating Unit inserted
properly?
⇒Pull out the the Plasmacluster
Ion Generating Unit and insert it
to the end again, and then carry
out the operation again.
• Unplug the Main Unit, wait one
minute, and then plug the Main
Unit in again.
FX-J80A_EN_090118.indd 12 10/5/2561 BE 10:39 AM

EN-13
SPECIFICATIONS
*1 • The recommended room size is appropriate for operating the main unit of maximum fan speed.
• The recommended room size is an area in which a given amount of dust particles can be removed in 30 minutes.
*2 • Room size in which approximately 25000 ions per cubic centimeter can be measured in the center of the room when the main unit is
placed next to a wall, is running at MED mode settings, and is at a height of approximately 1.2 meters from the oor.
Standby Power
When the main unit’s power plug is inserted in a wall outlet it consumes standby power in order to operate electrical
circuits. To conserve energy, unplug the power cord when the main unit is not in use.
Model FX-J80A
Power supply 220 V 50 Hz
Fan Speed Adjustment HIGH MED LOW
Fan Speed (m3/hour) 480 288 60
Noise Level (dBA) 47 45 15
Rated Power (W) 48 28 4.0
Standby Power (W) 1.3
Applicable Room Size (m2) *1~ 62
High density Plasmacluster ion
recommended room size (m2)
*2~ 35
Cord Length (m) 2.0
Dimensions (mm) 416 (W) × 291 (D) × 728 (H)
Weight (kg) 10.6
ENGLISH
FX-J80A_EN_090118.indd 13 10/5/2561 BE 10:39 AM

空氣清新機經吸氣口吸入室內空氣, 使其
通過主機內的前置過濾網、 活性碳除臭過
濾網 和 HEPA 集塵過濾網, 然後從吹出口
排出。
當空氣通過時, HEPA 集塵過濾網能夠去除
高達 99.97% 的粒徑小至 0.3 微米的灰塵粒
子, 同時還能幫助吸收異味。
當異味成分經過活性碳除臭過濾網時, 便
逐步被其吸收。
由於空氣清新機是收集房間整體的灰塵和異味成分的機器。 視使用情況, 尤其是倘若主機在較
普通家庭的空氣更嚴重的環境中使用, 該等異味可能比預期更加明顯。 如果保養還是無法去除
異味時, 請更換各種過濾網。 ( 參照 10 頁 )
注意
• 本空氣清新機用於去除空氣中懸浮的灰塵和異味。
而不能去除有害氣體 ( 如 : 香煙煙霧中的一氧化碳 )。
如果異味源仍然存在, 空氣清新機可能無法徹底去除異味。
目錄
重要安全事項............................................2
各部份名稱................................................4
安裝過濾網................................................6
操作方法
開始 / 停止 ............................................7
自動模式................................................7
強力 Ion 除菌模式 .................................7
高濃度定點淨化模式..............................7
風量模式................................................7
開機定時器 ............................................8
關機定時器 ............................................8
兒童安全鎖 ............................................8
PCI 開 / 關 .............................................8
各種功能的變更設定
...................................
9
亮度感測器 / 自動記憶功能 / 調校感測器的靈敏度
保養與清潔 / 更換
HEPA 集塵過濾網 / 活性碳除臭過濾網..10
主機 / 前置過濾網 ( 背板 ) .....................11
HD 離子產生器......................................11
維修前的檢查事項.....................................12
規格 ..........................................................13
操作您的新空氣清新機之前, 請詳細閱讀本手冊
中文
前置過濾網
HEPA 集塵過濾網
活性碳除臭過濾網
多謝您購買 SHARP 空氣清新機。
在使用空氣清新機前, 請詳細閱讀本手冊。
請將本手冊放在安全的地方, 方便查閱。
FX-J80A_CTHK_090118.indd 1 10/5/2561 BE 10:39 AM

ZH-1
空氣處理技術的獨特組合
三重過濾系統 + PCI
高濃度 PCI25000
PCI 濃度越高, 則 PCI 效率越高。
三重過濾系統
吸附灰塵
前置過濾網能夠吸附灰塵和其他尺寸較大的氣載粒子。
減少異味
活性碳除臭過濾網能吸收很多種常見的家居異味。
減少花粉和黴菌
HEPA 集塵過濾網能夠吸附高達 99.97% 的粒徑小至 0.3 微米的粒子。
獨有的氣流
強力吸氣及獨有的氣流快速及有效收集灰塵和其他顆粒。
透過 20 度角吹出的循環氣流, 可以更有效
地吸附房間內下方的灰塵。
PCI 可去除靜電, 因此能夠防止灰塵附着牆
上及其他表面。
PCI
PCI 對空氣進行處理的方法, 類似自然界釋出數量相等的正、 負離子來淨化空氣的過程。
PM2.5 感測功能
• 當敏感粉塵感測器檢測微小灰塵時, 燈亮後啟動 PM2.5 感測器。
• 以 3 位數顯示 PM2.5 值。
高濃度定點淨化模式
• 當異味及細菌附着沙發及窗簾時, 推薦使用本模式。
• 僅在前方向發出的高濃度 PCI 。
中文
FX-J80A_CTHK_090118.indd 1 10/5/2561 BE 10:39 AM

ZH-2
重要安全事項
使用電器時, 必須遵守基本安全預防措
施, 包括以下各方面 :
警告 - 為了減少電擊、 火災或受傷等危
險:
• 在使用主機之前請閱讀所有注意事項。
• 只能使用 220V 插座。
• 除非得到監護人或負責其安全人士的適當
監督或指導, 否則, 本機不適合身體機
能或心智能力退化者, 或缺乏操作經驗
和知識的人士 (包括兒童) 使用。
兒童應受到適當的監管, 以確保不會以
此機器作玩具。
• 如果電源線損壞, 必須由製造商或其代
理、 SHARP 公司特約維修機構或具有同
等資格的人員負責更換, 以免發生危險。
若本機出現任何問題、 需要調校或修理,
請聯絡客戶服務中心。
• 於維修前, 移除及連接及更換過濾器以
及長期不使用時, 確保移除電源插頭。
否則可能導致電擊或因短路引起火災。
• 如果電源線或插頭已經損壞, 或者牆上
的電源插座已鬆脫, 請勿使用主機。
• 定期清除電源插頭上的灰塵。
• 請勿將手指或異物插入吸氣或吹出口。
• 當拔掉電源插頭時, 必須緊握插頭而不
要拉扯電線。
否則可能導致電擊或因短路引起火災。
• 小心不要損壞電源線, 以免導致觸電、
過熱或起火。
• 手濕時請勿拔掉電源插頭。
• 不要靠近或在熱源物體上 (如爐灶或
暖爐式可能接觸到蒸汽的場所) 使用主
機。
• 當使用噴霧殺蟲劑時請勿使用主機。 倘
空氣中有油性殘留物、 薰香、 香煙火花
或化學煙霧, 則不得在室內操作主機。
浴室等可能被淋濕的地方也不要使用主
機。
• 清潔空氣清新機時請加以小心。 具強力
腐蝕性的清潔劑會損壞主機表面。
• 請保持主機遠離水源。 這樣做可能會導
致短路和 / 或觸電的發生。
注意 – 收音機或電視干擾
如果本空氣清新機對收音機或電視接收造成
干擾, 請嘗試以下列其中一項或多項措施
修正干擾 :
• 重新調整或重新放置接收天線。
• 增加主機與收音機/電視機接收器之間的
距離。
• 將主機與接收器連接至不同的電源插座或
供電線路。
• 如需協助, 請聯絡經銷商或專業的收音
機 / 電視技術人員。
FX-J80A_CTHK_090118.indd 2 10/5/2561 BE 10:39 AM

ZH-3
操作注意事項
• 請勿堵塞吸氣口和 / 或吹出口。
• 對主機進行操作時, 請始終保持其處於
直立狀態。
• 當主機處於運行狀態時, 切勿對其進行
移動。
• 在移動主機時, 應握持主機兩側的手柄。
• 在榻榻米墊、 易損的地面、 不平坦處及
較厚地毯上要將設備抬起來移動。
• 正確安裝過濾網之前切勿運行主機。
• 切勿清洗和重新使用 HEPA 集塵過濾網和
活性碳除臭過濾網。
這樣做不僅無法改善過濾網的性能, 而
且可能會導致觸電或機件故障的發生。
• 僅可使用柔軟的布對主機外部進行清潔。
切勿使用揮發性液體和 / 或清潔劑。
主機表面可能被汽油、 油漆稀釋劑或拋
光粉損壞或破裂。 另外, 還可能會導致
感測器發生故障。
• 請保持主機遠離水源。
• 保養與清潔時, 不得用力擦洗前置過濾
網(背板)。
安裝指南
• 請勿安裝在感測器直接對出風口的地方。
否則可能會影響主機正常工作。
• 避免在有可能與傢俱、 織物或其他物品
接觸的位置使用主機, 否則可能無法保
證吸氣口或吹出口的通暢。
• 請勿安裝在由於溫度劇烈變化而導致主機
直接暴露於冷凝環境的地方。 只適宜在
0-35℃之間的室溫下使用。
• 安裝必須穩固, 且通風良好。
把主機放置在鋪有厚地毯的地方時, 可
能導致主機微微震動。
• 避免在會產生油脂或含油煙霧的場所使用
主機。
否則可能會導致主機表面發生裂開, 或
是感測器發生故障。
• 在主機緊靠牆壁 3 厘米, 周圍的牆壁及
樓面可能變髒時其集塵的效能更高。 請
將主機與牆保持一定距離。
直接緊靠吹出口後面的牆壁可能於一段時
間後變髒。 當在同一位置使用主機的時
限延長時, 須定期清洗主機旁邊的牆壁。
過濾網指南
• 遵照說明書指示, 了解正確保養和清潔
過濾網的方法。
( 參照 10 頁 )
中文
FX-J80A_CTHK_090118.indd 3 10/5/2561 BE 10:39 AM

ZH-4
各部份名稱
主機
(正面)
(背部)
1. 操作面板
2. 吹出口(前/後方)
3. 淨化度指示燈
4. 顯示面板
5. 主機
6. 手柄 (2 處位置 )
7. 前風向板
8. 前置過濾網 ( 背板 )
9. 吸入口
10. 活性碳除臭過濾網
11. HEPA 集塵過濾網
12. 感測器過濾網 /
異味及高感度塵埃感測器
13. HD 離子產生器
14. 離子產生器支架
15. 離子產生器蓋
16. 離子產生器清潔刷
17. 電源線、 電源插頭
12
3
4
5
6
7
11
13
10
8
9
1514
12
16
17
FX-J80A_CTHK_090118.indd 4 10/5/2561 BE 10:39 AM
Table of contents
Other Sharp Air Cleaner manuals

Sharp
Sharp IG-DM1A Quick start guide

Sharp
Sharp FU-W40A User manual

Sharp
Sharp FU-W28J User manual

Sharp
Sharp IG-15TX1 User manual

Sharp
Sharp Plasmacluster IG-CL15U Setup guide

Sharp
Sharp FP-F30Y User manual

Sharp
Sharp FP-JC2 User manual

Sharp
Sharp FP-G50J User manual

Sharp
Sharp FU-888SV User manual

Sharp
Sharp UA-HD60E User manual

Sharp
Sharp KC-930EUW User manual

Sharp
Sharp KI-AB60-W User manual

Sharp
Sharp EH-HS41 User manual

Sharp
Sharp FX-J80M User manual

Sharp
Sharp FU-P60S-E User manual

Sharp
Sharp FU-S40E User manual

Sharp
Sharp FZ-Y30SFE Guide

Sharp
Sharp Plasmacluster FU-A80E User manual

Sharp
Sharp Plasmacluster KC-860U User manual

Sharp
Sharp Plasmacluster IG-A20E User manual