Table of contents
1 Introduction...................................................................................................................................................7
2 General scope of services ............................................................................................................................9
2.1 Routine test ............................................................................................................................11
2.2 Visual inspection ....................................................................................................................12
2.3 Function tests.........................................................................................................................13
2.4 Insulation test .........................................................................................................................14
2.5 Interface test ..........................................................................................................................15
3 Tests...........................................................................................................................................................17
3.1 Visual inspection ....................................................................................................................18
3.1.1 Rating plate ............................................................................................................................18
3.1.2 Housing degree of protection .................................................................................................18
3.1.3 Electrical cabinet components ...............................................................................................19
3.1.4 Cable installation....................................................................................................................19
3.1.5 Cable markings ......................................................................................................................20
3.1.6 Setting values of circuit breakers, if used...............................................................................20
3.1.7 Dimensions ............................................................................................................................20
3.2 Function test...........................................................................................................................22
3.2.1 Auxiliary voltages ...................................................................................................................22
3.2.2 Temperature monitoring in the control cabinet.......................................................................22
3.2.3 Redundant 230 V or 24 V auxiliary voltage supply ................................................................23
3.2.4 DC-link pulsed operation at 0 Hz ...........................................................................................23
3.2.5 DC-link pulsed operation at 2 Hz ...........................................................................................23
3.2.6 Line undervoltage...................................................................................................................24
3.2.7 Door limit switches .................................................................................................................24
3.2.8 Safety shutdown.....................................................................................................................25
3.3 Cooling system test................................................................................................................26
3.3.1 Air flow direction.....................................................................................................................26
3.3.2 Air pressure monitoring ..........................................................................................................26
3.4 Insulation test .........................................................................................................................27
3.4.1 High-voltage test ....................................................................................................................27
3.4.2 Measuring the insulation resistance.......................................................................................28
3.5 Interface test ..........................................................................................................................29
3.5.1 PROFIBUS communication....................................................................................................29
3.5.2 Signals to the customer's system...........................................................................................29
3.5.3 Additional interfaces...............................................................................................................30
Index...........................................................................................................................................................31
SINAMICS GL150 6SL3850 F03 F70 F98 E11