SIMATIC NET
Network components
Extender for SCALANCE XM-400
Operating Instructions
09/2018
C79000
-G8976-C332-08
Introduction
1
Safety notices
2
Recommendations on
network security
3
Description of the device
4
Installation
5
Connecting up
6
Technical specifications
7
Dimension drawings
8
Approvals
A

Siemens AG
Division Process Industries and Drives
Postfach 48 48
90026 NÜRNBERG
GERMANY
C79000-G8976-C332-08
Ⓟ
09/2018 Subject to change
Copyright © Siemens AG 2013 - 2018.
All rights reserved
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by
personnel qualified
for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.

Extender for SCALANCE XM-400
Operating Instructions, 09/2018, C79000-G8976-C332-08 3
Table of contents
1 Introduction............................................................................................................................................. 5
2 Safety notices ....................................................................................................................................... 11
3 Recommendations on network security ................................................................................................. 13
4 Description of the device....................................................................................................................... 19
4.1 Properties and functions .........................................................................................................19
4.2 Product overview ....................................................................................................................20
4.3 Device views ...........................................................................................................................23
4.3.1 PE408 .....................................................................................................................................23
4.3.2 PE408PoE ..............................................................................................................................24
4.3.3 PE400-8SFP ...........................................................................................................................25
4.4 Accessories.............................................................................................................................26
4.5 LED display.............................................................................................................................27
4.5.1 LEDs "2" and "3" .....................................................................................................................27
4.5.2 LEDs "L1" and "L2" .................................................................................................................28
4.5.3 Port LEDs................................................................................................................................28
4.6 Power over Ethernet (PoE).....................................................................................................30
5 Installation ............................................................................................................................................ 33
5.1 Safety notices for installation ..................................................................................................33
5.2 Types of installation ................................................................................................................34
5.3 Installation on a DIN rail..........................................................................................................35
5.4 Installation on a standard S7-300 rail .....................................................................................36
5.5 Installation on a standard S7-1500 rail ...................................................................................37
5.6 Fitting an extender ..................................................................................................................38
6 Connecting up....................................................................................................................................... 41
6.1 Safety when connecting up.....................................................................................................41
6.2 Further notes...........................................................................................................................42
6.3 PoE power supply of the PE408PoE ......................................................................................43
7 Technical specifications ........................................................................................................................ 47
7.1 Technical specifications of the PE408 ....................................................................................47
7.2 Technical specifications of the PE408PoE .............................................................................48
7.3 Technical specifications of the PE400-8SFP..........................................................................49

Table of contents
Extender for SCALANCE XM-400
4Operating Instructions, 09/2018, C79000-G8976-C332-08
8 Dimension drawings.............................................................................................................................. 51
A Approvals ............................................................................................................................................. 55
Index .................................................................................................................................................... 65

Extender for SCALANCE XM-400
Operating Instructions, 09/2018, C79000-G8976-C332-08 5
Introduction
1
Purpose of the Operating Instructions
These operating instructions support you when installing and connecting extenders within
the SCALANCE XM-400 product group.
The configuration and the integration of the device in a network are not described in these
operating instructions.
Validity of the Operating Instructions
These operating instructions apply to the following devices:
●Port extender PE408
●Port extender PE408PoE
●Port extender PE400-8SFP
Unless mentioned otherwise, the descriptions in these operating instructions refer to all
devices named in the section on validity.
Designations used
Classification
Description
Terms used
Product line The product line includes all devices and variants of all product groups.
If information applies to all product groups within the product line, the term X-400
is used.
X-400
Product group If information applies to all devices and variants of a product group, the term PE-
400 is used.
PE-400
Device If information relates to a specific device, the device name is used. PE408
PE408PoE
PE400-8SFP

Introduction
1.1 On the Operating Instructions
Extender for SCALANCE XM-400
6Operating Instructions, 09/2018, C79000-G8976-C332-08
Additional documentation
In addition, note the Operating Instructions of the basic devices SCALANCE XM-400 and the
pluggable transceivers.
When working with the port extender PE408PoE, note the documentation of the PoE power
supplies SCALANCE PS9230 PoE and SCALANCE PS924 PoE.
When using the Function Extender BUS ANALYZER Agent XM-400, note the documentation
of the BUS ANALYZER Agent XM-400.
You will find the supplementary documentation here:
●On the data medium that ships with some products:
–Product CD / product DVD
–SIMATIC NET Manual Collection
●On the Internet pages of Siemens Industry Online Support
(https://support.industry.siemens.com/cs/ww/en/ps/15315/man)
Documentation on configuration
You will find detailed information on configuring the devices in the following configuration
manuals:
●SCALANCE XM-400/XR-500 Web Based Management
●SCALANCE XM-400/XR-500 Command Line Interface
You will find the configuration manuals here:
●On the data medium that ships with some products:
–Product CD / product DVD
–SIMATIC NET Manual Collection
●On the Internet pages of Siemens Industry Online Support.
(https://support.industry.siemens.com/cs/ww/en/ps/15315)

Introduction
1.1 On the Operating Instructions
Extender for SCALANCE XM-400
Operating Instructions, 09/2018, C79000-G8976-C332-08 7
Further documentation
In the system manuals "Industrial Ethernet / PROFINET Industrial Ethernet" and "Industrial
Ethernet / PROFINET passive network components", you will find information on other
SIMATIC NET products that you can operate along with the devices of this product line in an
Industrial Ethernet network.
There, you will find among other things optical performance data of the communications
partner that you require for the installation.
You will find the system manuals here:
●On the data medium that ships with some products:
–Product CD / product DVD
–SIMATIC NET Manual Collection
●On the Internet pages of Siemens Industry Online Support:
–Industrial Ethernet / PROFINET Industrial Ethernet System Manual
(https://support.industry.siemens.com/cs/ww/en/view/27069465)
–Industrial Ethernet / PROFINET Passive Network Components System Manual
(https://support.industry.siemens.com/cs/ww/en/view/84922825)
SIMATIC NET manuals
You will find the SIMATIC NET manuals here:
●On the data medium that ships with some products:
–Product CD / product DVD
–SIMATIC NET Manual Collection
●On the Internet pages of Siemens Industry Online Support
(https://support.industry.siemens.com/cs/ww/en/ps/15247).
SIMATIC NET glossary
Explanations of many of the specialist terms used in this documentation can be found in the
SIMATIC NET glossary.
You will find the SIMATIC NET glossary here:
●SIMATIC NET Manual Collection or product DVD
The DVD ships with certain SIMATIC NET products.
●On the Internet under the following address:
50305045 (https://support.industry.siemens.com/cs/ww/en/view/50305045)

Introduction
1.1 On the Operating Instructions
Extender for SCALANCE XM-400
8Operating Instructions, 09/2018, C79000-G8976-C332-08
Security information
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is
necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens’ products and solutions constitute one element of such a concept.
Customers are responsible for preventing unauthorized access to their plants, systems,
machines and networks. Such systems, machines and components should only be
connected to an enterprise network or the internet if and to the extent such a connection is
necessary and only when appropriate security measures (e.g. firewalls and/or network
segmentation) are in place.
For additional information on industrial security measures that may be implemented, please
visit
https://www.siemens.com/industrialsecurity (https://www.siemens.com/industrialsecurity)
Siemens’ products and solutions undergo continuous development to make them more
secure. Siemens strongly recommends that product updates are applied as soon as they are
available and that the latest product versions are used. Use of product versions that are no
longer supported, and failure to apply the latest updates may increase customers’ exposure
to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS
Feed under
https://www.siemens.com/industrialsecurity (https://www.siemens.com/industrialsecurity)
Catalogs
You will find the article numbers for the Siemens products of relevance here in the following
catalogs:
●SIMATIC NET Industrial Communication / Industrial Identification, catalog IK PI
●SIMATIC Products for Totally Integrated Automation and Micro Automation, catalog
ST 70
●Industry Mall - catalog and ordering system for automation and drive technology, Online
catalog
(https://mall.industry.siemens.com/goos/WelcomePage.aspx?regionUrl=/en&language=e
n)
You can request the catalogs and additional information from your Siemens representative.

Introduction
1.1 On the Operating Instructions
Extender for SCALANCE XM-400
Operating Instructions, 09/2018, C79000-G8976-C332-08 9
Device defective
If a fault develops, please send the device to your SIEMENS service center for repair.
Repairs on-site are not possible.
Recycling and disposal
The products are low in pollutants, can be recycled and meet the requirements of the WEEE
directive 2012/19/EU for the disposal of electrical and electronic equipment.
Do not dispose of the products at public disposal sites.
For environmentally friendly recycling and the disposal of your old device contact a certified
disposal company for electronic scrap or your Siemens contact (Product return
(https://support.industry.siemens.com/cs/ww/en/view/109479891)).
Note the different national regulations.
Trademarks
The following and possibly other names not identified by the registered trademark sign ®are
registered trademarks of Siemens AG:
SIMATIC NET, SCALANCE, C-PLUG, OLM

Introduction
1.1 On the Operating Instructions
Extender for SCALANCE XM-400
10 Operating Instructions, 09/2018, C79000-G8976-C332-08

Extender for SCALANCE XM-400
Operating Instructions, 09/2018, C79000-G8976-C332-08 11
Safety notices
2
Read the safety notices
Note the following safety notices. These relate to the entire working life of the device.
You should also read the safety notices relating to handling in the individual sections,
particularly in the sections "Installation" and "Connecting up".
CAUTION
To prevent injury, read the manual before use.
Safety notices on use in hazardous areas
General safety notices relating to protection against explosion
WARNING
EXPLOSION HAZARD
Do not open the device when the supply voltage is turned on.
Safety notices when using the device according to Hazardous Locations (HazLoc)
If you use the device under HazLoc conditions you must also keep to the following safety
notices in addition to the general safety notices for protection against explosion:
This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or non-
hazardous locations only.
This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations
only.

Safety notices
Extender for SCALANCE XM-400
12 Operating Instructions, 09/2018, C79000-G8976-C332-08

Extender for SCALANCE XM-400
Operating Instructions, 09/2018, C79000-G8976-C332-08 13
Recommendations on network security
3
NOTICE
Information security
Connect to the device and change the standard password for the user set in the factory
"admin" and "" before you operate the device.
To prevent unauthorized access, note the following security recommendations.
General
●You should make regular checks to make sure that the device meets these
recommendations and/or other security guidelines.
●Evaluate your plant as a whole in terms of security. Use a cell protection concept with
suitable products (https://www.industry.siemens.com/topics/global/en/industrial-
security/pages/default.aspx).
●When the internal and external network are disconnected, an attacker cannot access
internal data from the outside. Therefore operate the device only within a protected
network area.
●For communication via non-secure networks use additional devices with VPN functionality
to encrypt and authenticate the communication.
●Terminate management connections correctly (WBM. Telnet, SSH etc.).
Physical access
●Restrict physical access to the device to qualified personnel.
–The memory card or the PLUG (C-PLUG, KEY-PLUG) contains sensitive data such as
certificates, keys etc. that can be read out and modified.
–Using the button, you can reset the device to the factory defaults.
●If the device is publicly accessible, disable the functions of the button using the software.
●Lock unused physical ports on the device. Unused ports can be used to gain forbidden
access to the plant.

Recommendations on network security
Extender for SCALANCE XM-400
14 Operating Instructions, 09/2018, C79000-G8976-C332-08
Software (security functions)
●Keep the firmware up to date. Check regularly for security updates for the device. You
can find information on this at the Industrial Security
(https://www.siemens.com/industrialsecurity) website.
●Inform yourself regularly about security recommendations published by Siemens
ProductCERT (https://www.siemens.com/cert/en/cert-security-advisories.htm).
●Only activate protocols that you require to use the device.
●Restrict access to the management of the device with rules in an access control list
(ACL).
●The option of VLAN structuring provides protection against DoS attacks and unauthorized
access. Check whether this is practical or useful in your environment.
●Use a central logging server to log changes and accesses. Operate your logging server
within the protected network area and check the logging information regularly.
Passwords
●Define rules for the assignment of passwords.
●Regularly change your passwords to increase security.
●Use passwords with a high password strength.
●Make sure that all passwords are protected and inaccessible to unauthorized persons.
●Do not use the same password for different users and systems.
Certificates and keys
●On the device there is a preset SSL certificate with key. Replace this certificate with a
self-made certificate with key. We recommend that you use a certificate signed either by
a reliable external or by an internal certification authority.
●Use a certification authority including key revocation and management to sign certificates.
●Make sure that user-defined private keys are protected and inaccessible to unauthorized
persons.
●It is recommended that you use password-protected certificates in the PKCS #12 format
●Verify certificates and fingerprints on the server and client to prevent "man in the middle"
attacks.
●It is recommended that you use certificates with a key length of at least 2048 bits.
●Change certificates and keys immediately, if there is a suspicion of compromise.

Recommendations on network security
Extender for SCALANCE XM-400
Operating Instructions, 09/2018, C79000-G8976-C332-08 15
Secure/non-secure protocols and services
●Avoid or disable non-secure protocols and services, for example HTTP, Telnet and TFTP.
For historical reasons, these protocols are available, however not intended for secure
applications. Use non-secure protocols on the device with caution.
●Check whether use of the following protocols and services is necessary:
–Non authenticated and unencrypted ports
–MRP, HRP
–IGMP snooping
–LLDP
–Syslog
–RADIUS
–DHCP Options 66/67
–TFTP
–GMRP and GVRP
●The following protocols provide secure alternatives:
–HTTP →HTTPS
–Telnet →SSH
–SNMPv1/v2c →SNMPv3
Check whether use of SNMPv1/v2c. is necessary. SNMPv1/v2c is classified as non-
secure. Use the option of preventing write access. The device provides you with
suitable setting options.
If SNMP is enabled, change the community names. If no unrestricted access is
necessary, restrict access with SNMP.
Use the authentication and encryption mechanisms of SNMPv3.
●Use secure protocols when access to the device is not prevented by physical protection
measures.
●If you require non-secure protocols and services, operate the device only within a
protected network area.
●Restrict the services and protocols available to the outside to a minimum.
●For the DCP function, enable the "Read Only" mode after commissioning.
●If you use RADIUS for management access to the device, activate secure protocols and
services.

Recommendations on network security
Extender for SCALANCE XM-400
16 Operating Instructions, 09/2018, C79000-G8976-C332-08
Interfaces security
●Disable unused interfaces.
●Use IEEE 802.1X for interface authentication.
●Use the function "Locked Ports" to block interfaces for unknown nodes.
●Use the configuration options of the interfaces, e.g. the "Edge Type".
●Configure the receive ports so that they discard all untagged frames ("Tagged Frames
Only").
Available protocols
The following list provides you with an overview of the open protocol ports.
The table includes the following columns:
●
Protocol
●
Port
●
Default port status
–Open
The factory setting of the port is "Open".
–Closed
The factory setting of the port is "Closed".
●
Configurable port
–✓
The port status can be changed.
–--
The port status cannot be changed.
●
Authentication
Specifies whether the communication partner is authenticated.
●
Encryption
Specifies whether or not the transfer is encrypted.

Recommendations on network security
Extender for SCALANCE XM-400
Operating Instructions, 09/2018, C79000-G8976-C332-08 17
Protocol
Protocol/
Port number
Default port status
Configurable port
Authentication
Encryption
TELNET
TCP/23
Open
--
Yes
No
SSH
TCP/22 Open -- Yes Yes
HTTP
TCP/80
Open
--
Yes
No
HTTPS
TCP/443
Open
✓
Yes
Yes
SNMP
UDP/161 Open ✓Yes Yes
(when configured)
SNTP
NTP
UDP/123 Closed ✓No No
PROFINET
UDP/34964,
UDP/49154, 49155
Open -- No No
EtherNet/IP
TCP/44818,
UDP/2222,44818
Closed ✓No No
DHCP
UDP/67,68
Open
✓
No
No
Syslog
UDP/514
Closed
✓
No
No
RADIUS
UDP/1812,1813
Closed
✓
No
No
TFTP
UDP/69
Open
--
No
No
RIP
UDP/520
Closed
--
No
No

Recommendations on network security
Extender for SCALANCE XM-400
18 Operating Instructions, 09/2018, C79000-G8976-C332-08

Extender for SCALANCE XM-400
Operating Instructions, 09/2018, C79000-G8976-C332-08 19
Description of the device
4
4.1
Properties and functions
SCALANCE XM-400 product group
The product group SCALANCE XM-400 consists of basic devices (compact switches) and
extenders (port extenders and function extender).
SCALANCE XM-400 basic device
Basic properties
The SCALANCE XM-400 basic devices are modular compact switches with fixed RJ-45
ports (10/100/1000 Mbps) and SFP transceiver slots that can be equipped individually. The
SFP transceiver slots are combo ports.
A SCALANCE XM-400 can manage a maximum of 24 ports with 10/100/1000 Mbps.
The following components exist only on the basic device:
●CPU
●Power supply
●Signaling contact
●Out-of-band port
●Serial interface
●"SELECT / SET" button
Expansions
The basic devices can be expanded with additional ports and functions by using an
extender. The extenders are connected to the side of the basic device. Each basic device
has an expansion interface to the left for function extenders and to the right an expansion
interface for port extenders.
Depending on the number of ports of the basic device (10/100/1000 Mbps) up to 2 port
extenders can be added. Further port extenders are not supplied with power. There is no
particular order in which the port extenders need to be added.
Example:
●The basic device SCALANCE XM408-8C has 8 ports. It can therefore be expanded by 2
port extenders each with 8 ports.
●The basic device SCALANCE XM416-4C has 16 ports. It can therefore be expanded by
one port extender with 8 ports.
A function extender can be added.

Description of the device
4.2 Product overview
Extender for SCALANCE XM-400
20 Operating Instructions, 09/2018, C79000-G8976-C332-08
Port extender PE-400
Port extenders are modular network components with RJ-45 ports (10/100/1000 Mbps) or
SFP transceiver slots. To the left they have an expansion interface to connect to the basic
device or to another port extender and to the right they have an expansion interface for
additional port extenders. Each port extender functions with every basic device.
Note
Port extenders function only in conjunction with a basic device.
Function Extender BUS ANALYZER Agent XM-400
Function extenders are modular network components that expand the range of functions of
the basic device.
To the right they have an expansion interface to connect to the basic device. Function
extenders can be used with every basic device.
The BUS ANALYZER Agent XM-400 can be used as a function extender for SCALANCE
XM-400.
As a function extender the BUS ANALYZER Agent XM-400 is a modular network component
with 4 internal monitor ports for port mirroring. On the internal ports of the BUS ANALYZER
Agent XM-400, ports of the basic device can be mirrored and their data traffic recorded. The
BUS ANALYZER Agent XM-400 has an expansion interface to the right to connect to the
basic device. It can be used with every basic device.
In standalone mode, the BUS ANALYZER Agent XM-400 is an independent hardware
module for recording and sending Ethernet and PROFINET data without any consequences.
You will find detailed information in the operating instructions of the BUS ANALYZER Agent
XM-400, see section "Introduction" page 5, subsection "Additional documentation".
4.2
Product overview
Port extender
Type
Properties
Article number
PE408
8 x 10/100/1000 Mbps RJ-45 ports
6GK5 408-0GA00-8AP2
PE408PoE
8 x 10/100/1000 Mbps, RJ-45 ports with PoE
6GK5 408-0PA00-8AP2
PE400-8SFP
8 x 100/1000 Mbps, SFP ports
6GK5 400-8AS00-8AP2
This manual suits for next models
2
Table of contents
Other Siemens Extender manuals

Siemens
Siemens SPCE110 User manual

Siemens
Siemens PAD-3 User manual

Siemens
Siemens 505-2571 User manual

Siemens
Siemens SIMATIC User manual

Siemens
Siemens SPCW130 User manual

Siemens
Siemens PSX-12 User manual

Siemens
Siemens PAD-4 User manual

Siemens
Siemens PSX-12C User manual

Siemens
Siemens 6ES7 972-4AA02-0XA0 User manual

Siemens
Siemens SPCE120 User manual