EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Siemens
  6. •
  7. Industrial Equipment
  8. •
  9. Siemens MindConnect Nano User manual

Siemens MindConnect Nano User manual

Other manuals for MindConnect Nano

4

Other Siemens Industrial Equipment manuals

Siemens SIMATIC HMI ITC1200 V3 PRO User manual

Siemens

Siemens SIMATIC HMI ITC1200 V3 PRO User manual

Siemens SIRIUS 3RW55 Technical Document

Siemens

Siemens SIRIUS 3RW55 Technical Document

Siemens SGT-400 User manual

Siemens

Siemens SGT-400 User manual

Siemens 3RA233.-8X.30-1 User manual

Siemens

Siemens 3RA233.-8X.30-1 User manual

Siemens SIMOGEAR BA 2039 User manual

Siemens

Siemens SIMOGEAR BA 2039 User manual

Siemens SIRIUS 3UG4633 User manual

Siemens

Siemens SIRIUS 3UG4633 User manual

Siemens 7VE51 User manual

Siemens

Siemens 7VE51 User manual

Siemens SIRIUS 3RT2.1 Series User manual

Siemens

Siemens SIRIUS 3RT2.1 Series User manual

Siemens SIMATIC NET SCALANCE M826 User manual

Siemens

Siemens SIMATIC NET SCALANCE M826 User manual

Siemens SIMATIC RTLS PCB OEM PULSE User manual

Siemens

Siemens SIMATIC RTLS PCB OEM PULSE User manual

Siemens 3TK2810-1 User manual

Siemens

Siemens 3TK2810-1 User manual

Siemens SIMATIC NET SCALANCE SC-600 User manual

Siemens

Siemens SIMATIC NET SCALANCE SC-600 User manual

Siemens APACS+ Manual

Siemens

Siemens APACS+ Manual

Siemens SIRIUS 3RV29 Series User manual

Siemens

Siemens SIRIUS 3RV29 Series User manual

Siemens SIRIUS 3RT1964-6V User manual

Siemens

Siemens SIRIUS 3RT1964-6V User manual

Siemens Sivacon S8 User manual

Siemens

Siemens Sivacon S8 User manual

Siemens 3VW9011-5AA00 User manual

Siemens

Siemens 3VW9011-5AA00 User manual

Siemens 3SU1400-2H 10-6AA0 Series User manual

Siemens

Siemens 3SU1400-2H 10-6AA0 Series User manual

Siemens RUGGEDCOM RP110 User manual

Siemens

Siemens RUGGEDCOM RP110 User manual

Siemens SIMATIC MV320 User manual

Siemens

Siemens SIMATIC MV320 User manual

Siemens 3RW2920-1 05 Series User manual

Siemens

Siemens 3RW2920-1 05 Series User manual

Siemens SINAMICS S120 Installation and operation manual

Siemens

Siemens SINAMICS S120 Installation and operation manual

Siemens SIMATIC HMI User manual

Siemens

Siemens SIMATIC HMI User manual

Siemens WZU-485E-MOD User manual

Siemens

Siemens WZU-485E-MOD User manual

Popular Industrial Equipment manuals by other brands

ABB Unifix AD Instruction handbook

ABB

ABB Unifix AD Instruction handbook

Mark 7 Evolution user manual

Mark 7

Mark 7 Evolution user manual

Husky HyPET Original instructions

Husky

Husky HyPET Original instructions

bora PM-1800 user manual

bora

bora PM-1800 user manual

Grizzly T32428 owner's manual

Grizzly

Grizzly T32428 owner's manual

ABB HT610965 Operation manual

ABB

ABB HT610965 Operation manual

ABB SafeLink Installation and operating instructions

ABB

ABB SafeLink Installation and operating instructions

Phoenix PHX-150 user guide

Phoenix

Phoenix PHX-150 user guide

ABB A165-L32 Operation manual

ABB

ABB A165-L32 Operation manual

ABB HT842936 Operation manual

ABB

ABB HT842936 Operation manual

Hermetica 10 Series user manual

Hermetica

Hermetica 10 Series user manual

HORNER OEE Solution manual

HORNER

HORNER OEE Solution manual

Hammerhead HG375 parts manual

Hammerhead

Hammerhead HG375 parts manual

SCHUNK VERO-S NSE-A3 138 Assembly and operating manual

SCHUNK

SCHUNK VERO-S NSE-A3 138 Assembly and operating manual

ABB HT566657 Operation manual

ABB

ABB HT566657 Operation manual

Webasto GSE CAN installation guide

Webasto

Webasto GSE CAN installation guide

ABB HT614003 Operation manual

ABB

ABB HT614003 Operation manual

BAC BCP2D Installation, Operating, Maintenance

BAC

BAC BCP2D Installation, Operating, Maintenance

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

siemens.com/mindsphere
MindConnect Nano
Quick Start
7. Use MindSphere
Once MindConnect Nano is onboarded, you can configure
your Asset for data collection. After you have configured
asset data, MindConnect Nano starts the data acquisition.
You can now start the Fleet Manager and Visual Analyzer
to see your machine data.
For additional information go to MindSphere – Getting
Started.
Requirements
• PC with internet connection for MindSphere configuration
• Browser for online user interface, supporting HTML5
(e. g. Firefox, Google Chrome, Safari, Opera)
• Login data for MindSphere Access provided by Siemens
after ordering MindSphere
• Power Supply, 24 V DC
• Standard USB stick, one partition, FAT32 formatted
Further Information
• MindSphere – Getting Started
• MindSphere – FAQs
• Industry Online Support
https://support.industry.siemens.com
This document contains illustrations and accessories.
The illustrations may deviate from the particularities of the
delivered device and accessories.
We have reviewed the contents of this publication to ensure
consistency with the hardware and software described. Since
variance cannot be entirely excluded, we cannot guarantee full
consistency. However, the information in this publication is
reviewed regularly and all necessary corrections will be includ-
ed in subsequent editions.
In order to protect plants, systems, machines and networks
against cyber threats, it is necessary to implement – and
continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens’ products and solutions only form
one element of such a concept. For more information about
industrial security, please visit
siemens.com/industrialsecurity.
© Siemens AG 2017
Digital Factory
P.O. Box 48 48
90026 Nuremberg
Germany
Subject to change without prior notice
Article No.: DFPL-T10029-00-7600
Dispo 21639
fb 7328 WS 07160.25 A5E38886585-AC
Printed in Germany
The information provided in this brochure contains merely general
descriptions or characteristics of performance which in case of actual
use do not always apply as described or which may change as a result
of further development of the products. An obligation to provide the
respective characteristics shall only exist if expressly agreed in the
1. Mount MindConnect Nano
Mounting positions permitted vertical or horizontal
Please make sure there’s enough space around the device
above: ≥ 50 mm, below: ≥ 100 mm
50 mm
100 mm
2. Connect Power Supply
1. Connect the protective earth (see Getting Started)
2. Secure the cables
3. Connect the power supply
DC 24 V
Power Supply
3. Connect with your Network
1. Connect the internet to the X1P1 port for MindSphere
connection (see Getting Started)
2. Important: Don’t connect anything to the right port yet!
3. Switch on the device
4. Onboarding Process
1. Login
Access the MindSphere portal
via the provided URL from the
browser on your PC.
2. Asset Configuration
Open the Asset configuration
App and follow the onboard-
ing process.
(see Getting Started)
3. Enter MindConnect Nano
information
Enter the MindConnect Nano
InfoID. The rating plate is
located on the back panel of
the device.
4. Network Connection
1. Configure Ethernet Inter-
face for data aquisition
2. Configure Ethernet Inter-
face for MindSphere Connect
3.Configure Proxy Configura-
tion
5. Download Configuration to USB
1. To complete the configuration, click the button Save.
2. Goto to Overview and click Save and Export to USB.
3. Download the configuration file for the asset and copy it
to the root directory of your USB stick.
Note: Use USB stick with one FAT32 formatted partition.
Configuration file is valid only for seven days.
6. Plug USB into MindConnect Nano
1. Power LED (PC ON/WD) of MindConnect Nano is green.
2. Insert the USB stick with configured asset data into the
USB port (X63) of MindConnect Nano.
3. The MindConnect Nano automatically reads the USB stick
data (RUN/STOP/L1 LED blinks orange), followed by a
restart.
4. MindConnect Nano then attempts to establish connection
to MindSphere.
5. After a few seconds the RUN/STOP/L1 LED should be green
and UI has the state Onboarded, which means it is
connected to MindSphere. (If the onboarding is not
successful, see Getting Started)
6. After successful onboarding, connect the plant network
to the X2P1 port.
7. Now remove USB stick from the MindConnect Nano.