The Physical Block (PA Slot 0), PROFIBUS
2.3 Physical Block (PA Slot 0) Parameter List, PROFIBUS
SITRANS TH400 PROFIBUS® PA
8 Configuration Manual, 02/2007, A5E01039143-01
2.3 Physical Block (PA Slot 0) Parameter List, PROFIBUS
Parameter Rel.
Index Description Type Store Size R/W Min Max Default
ST_REV 1 Is incremented each time that there is a change in a static
parameter in the physical block.
Unsigned
16 N 2 RO 0
TAG_DESC 2 Tag name of the block. This parameter must be unique in the
configuration.
OCTET_
STRING SRC 32 R/W "
STRATEGY 3 This can be used to group a Function Block. It is a user supplied
parameter for identification purpose.
Unsigned
16 SRC 2 R/W 0
ALERT_KEY 4 Current state of alarm blocks Unsigned 8 SRC 1 R/W 0
TARGET_MODE 5 Current desired mode of the block. Unsigned 8 SRC 1 R/W -
MODE_BLK 6
A block has static block parameters, that are not changed by the
process. Values are assigned to this parameter during the
configuration or optimisation. The value of ST_REV must increase
by 1 after every change of a static block parameter. This provides a
check of the parameter revision.
DS-37 D 3 RO Block
specific
ALARM_SUM 7 Current state of the blocks alarms. DS-42 D 8 RO 0,0,0,0
SOFTWARE_REVISION 8 Software revision of the device VISBLE_
STRING Cst 16 RO
HARDWARE_REVISION 9 Physical revision of the device. VISBLE_
STRING Cst 16 RO
DEVICE_MAN_ID 10 Siemens AG manufacturer identification number. Unsigned
16 Cst 2 RO 0x006D
DEVICE_ID 11 Manufacturer device number VISBLE_
STRING Cst 16 RO
SITRAN
S
TH400
DEVICE_SER_NUM 12 Device serial number VISBLE_
STRING Cst 16 RO
DIAGNOSIS 13 Bit string indicating the diagnosis of the device. See Diagnosis OCTET_
STRING D 4 RO
DIAGNOSIS_
EXTENSION 14 Not used. OCTET_
STRING D 6 RO
DIAGNOSIS_MASK 15 Not used. OCTET_
STRING Cst 4 RO
DIAGNOSIS_MASK_
EXTENSION 16 Not used. OCTET_
STRING Cst 6 RO
DEVICE_
CERTIFICATION 17 PA device certification VISBLE_
STRING Cst 32 RO
WRITE_LOCKING 18 If Locked, no writes from anywhere are allowed, except to clear
WRITE_LOCK. Cyclic block inputs will continue to be updated.
Unsigned
16 N 2 R/W
FACTORY_RESET 19
Factory reset:
1: Restart with default
2506: Restart processor
2712: Recover default address to the device
Unsigned
16 SRC 2 R/W
DESCRIPTOR 20 It is a user supplied description of the block in the application. OCTET_
STRING SRC 32 R/W
DEVICE_MESSAGE 21
It is a user supplied Message of the block in the application.
OCTET_
STRING SRC 32 R/W