A6V10456397_enUS_c
Siemens Industry, Inc.
2016-06-16 Building Technologies Division
LED annunciator
FT2008-U1/FT2008-R1/FT2009-U1/FT2009-R1
Installation Instruction
1
1
2
3
4
4
4
5
5
6
6
7
7
8
10
11
11
9
9
12
FT2008-U1/FT2008-R1 FT2009-U1/FT2009-R1
·For Canadian applications, the “FT2008-U1”/“FT2008-R1”/“FT2009-U1”/“FT2009-R1” are deemed supplementary and
can be used for display only. It must be housed in a ULC-S527 approved, locked, enclosure.
·Not approved for UL/ULC MNS applications.
Issued by
Siemens Industry, Inc.
Building Technology Division
8 Fernwood Road
Florham Park, NJ 08932
Tel. +1 973-593-2600
www.sbt.siemens.com/FIS
@2016 Siemens Industry, Inc.
Technical specifications and availability subject to change without notice.
Doc No. A6V10456397_enUS_c 101590209
Edition 2016-06-16
Intended use
The FT2008/FT2009 LED annunciator enables the fire
detection system to be displayed and operated in a
simplified way. The FT2008 provides 2×16 LEDs to
display alarm/trouble events. The FT2009 provides 2×32
LEDs to display alarm/trouble events. Both devices are
operated on the UFP line.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received,
including interference that may cause undesired operation.
Package contents
The following are included in the scope of delivery:
lFT2008-U1/FT2008-R1 or FT2009-U1/FT2009-R1
lCable ties (2 pcs)
lEOL jumper connecter (1 pcs)
Safety instructions
Risk of injury to persons and damage to property
Please observe the following safety instructions:
l
The devices are only intended for stationary installation
in dry rooms.
lThe devices may only be connected to the UFP line.
lIf panel AUX power is not used, an UL listed/recognized
for fire use, regulated, power limited 24V DC power
supply is required.
lStatic discharge precautions should be taken when
handling the FT2008/FT2009.
Legend
1Stub for mounting cover (2 pcs.)
2 Shield terminal
3 Earth ground terminal
4 Mounting holes (8 pcs.)
5 Cable tie point
6 Breakout openings for cables (2 pcs.)
7 Holes for hanging front panel over stub (2 pcs.)
8 Dip-switch
9 Screws (2 pcs.)
10 EOL jumper
11 Connection terminals for UFP line and power supply
12 Front panel earth ground connection
Mounting instruction
1. Break out the required cable openings (6) on the
backbox.
2. Mark the drilling points for the 3 mounting holes (4), drill
the holes and insert the anchors (not supplied); or use
the pre drilled mounting holes for installation on a 2
gang, or 4” square standard electrical box.
3. Pull the cables for the UFP and power supply, through
the breakout openings (6) on the backbox.
4. Screw the backbox tightly in place.
5. Connect the cable to the terminal (11) in accordance
with the connection diagram.
6. Configure Dip-switch (8) and EOL jumper (10).
7. Connect the green earth ground cable from front panel
(12) to backbox (3).
8. Hook the front panel with the holes (7) over the stubs (1)
on the backbox.
9. Press the front panel down over the backbox, screw (9)
upwards and fix the front panel in place.
Dip-switch
8-digit Dip-switch is used for setting address and baud rate.
The first 1-4 digits are for setting address, the 7-8 digits are
for setting UFP communication baud rate. The 5-6 digits are
reserved for future use.
Add. Dip-switch Baud Rate Dip-switch
1 2 3 4 7 8
1On Off Off Off 9600 bps Off Off
2 Off On Off Off 19200 bps On Off
3 On On Off Off 38400 bps Off On
4 Off Off On Off 57600 bps On On
5On Off On Off
6 Off On On Off
7 On On On Off
8 Off Off Off On
Technical data
FT2008 FT2009
Weight 2.646 lb 3.748 lb
Dimensions (W x H x D)
(In: inch)
8.110x7.362
x1.949
11.417x7.362
x1.949
Storage temperature 14…140 °F
Operating temperature 32…120.2 °F
Humidity ≤93% rel.
Housing IP30
Operating voltage 24V DC Nominal
18.8…27.2V DC
Operating current 25 mA 25 mA
Activation current 65 mA 105 mA

This manual suits for next models

3

Other Siemens Measuring Instrument manuals

Siemens SICAM MMU 7KG9663 Application guide

Siemens

Siemens SICAM MMU 7KG9663 Application guide

Siemens SITRANS FC430 Administrator guide

Siemens

Siemens SITRANS FC430 Administrator guide

Siemens SITRANS AID IQ User manual

Siemens

Siemens SITRANS AID IQ User manual

Siemens FUG1010 IP65 NEMA 4X User manual

Siemens

Siemens FUG1010 IP65 NEMA 4X User manual

Siemens SIPROCESS GA700 User manual

Siemens

Siemens SIPROCESS GA700 User manual

Siemens SITRANS FUS060 HART User manual

Siemens

Siemens SITRANS FUS060 HART User manual

Siemens sitrans PROBE LU User manual

Siemens

Siemens sitrans PROBE LU User manual

Siemens SITRANS LR560 Instruction manual

Siemens

Siemens SITRANS LR560 Instruction manual

Siemens SICAM Q100 User guide

Siemens

Siemens SICAM Q100 User guide

Siemens OCM III User manual

Siemens

Siemens OCM III User manual

Siemens SICAM Q100 7KG95 Series User manual

Siemens

Siemens SICAM Q100 7KG95 Series User manual

Siemens VDO E-Tacho 1323.01 User manual

Siemens

Siemens VDO E-Tacho 1323.01 User manual

Siemens SIRIUS 3RN2 User manual

Siemens

Siemens SIRIUS 3RN2 User manual

Siemens SITRANS FX300 User manual

Siemens

Siemens SITRANS FX300 User manual

Siemens 6 Series Administrator guide

Siemens

Siemens 6 Series Administrator guide

Siemens Class 87 Manual

Siemens

Siemens Class 87 Manual

Siemens 7LQ3 350 User manual

Siemens

Siemens 7LQ3 350 User manual

Siemens ULTRAHEAT T550 Series User manual

Siemens

Siemens ULTRAHEAT T550 Series User manual

Siemens sitrans LU01 User manual

Siemens

Siemens sitrans LU01 User manual

Siemens SITRANS F C MASSFLO MASS 6000 User manual

Siemens

Siemens SITRANS F C MASSFLO MASS 6000 User manual

Siemens SITRANS FS230 User manual

Siemens

Siemens SITRANS FS230 User manual

Siemens SITRANS F FST030 User manual

Siemens

Siemens SITRANS F FST030 User manual

Siemens SITRANS LG260 User manual

Siemens

Siemens SITRANS LG260 User manual

Siemens Opdima MAMMOMAT 1000 Instructions and recipes

Siemens

Siemens Opdima MAMMOMAT 1000 Instructions and recipes

Popular Measuring Instrument manuals by other brands

Dupla Twin-Control Using instruction

Dupla

Dupla Twin-Control Using instruction

Omega FPD-4000 Series user guide

Omega

Omega FPD-4000 Series user guide

SICK GM700 operating instructions

SICK

SICK GM700 operating instructions

PERSEE T8DS user manual

PERSEE

PERSEE T8DS user manual

Endress+Hauser Proline Promag W 500 operating instructions

Endress+Hauser

Endress+Hauser Proline Promag W 500 operating instructions

TESTO 610 instruction manual

TESTO

TESTO 610 instruction manual

kaarta STENCIL PRO user guide

kaarta

kaarta STENCIL PRO user guide

SZBJ BM802A instruction manual

SZBJ

SZBJ BM802A instruction manual

Fakopp DynaTree manual

Fakopp

Fakopp DynaTree manual

Hyelec PeakMeter MS2108 manual

Hyelec

Hyelec PeakMeter MS2108 manual

Weigel DMA14-31 A 20 R-S1 operating instructions

Weigel

Weigel DMA14-31 A 20 R-S1 operating instructions

ARMANO RCh series operating instructions

ARMANO

ARMANO RCh series operating instructions

Lutron Electronics MS-7011 Operation manual

Lutron Electronics

Lutron Electronics MS-7011 Operation manual

Bauhn PA39085 instruction manual

Bauhn

Bauhn PA39085 instruction manual

KRAL BEM 100 Original instructions

KRAL

KRAL BEM 100 Original instructions

Seetru Quickmount Installation, operating and maintenance instructions

Seetru

Seetru Quickmount Installation, operating and maintenance instructions

Emos P5805 manual

Emos

Emos P5805 manual

OTC 4278 user manual

OTC

OTC 4278 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.