manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Siemens
  6. •
  7. Measuring Instrument
  8. •
  9. Siemens FT2008-U1 User manual

Siemens FT2008-U1 User manual

A6V10456397_enUS_c
Siemens Industry, Inc.
2016-06-16 Building Technologies Division
LED annunciator
FT2008-U1/FT2008-R1/FT2009-U1/FT2009-R1
Installation Instruction
1
1
2
3
4
4
4
5
5
6
6
7
7
8
10
11
11
9
9
12
FT2008-U1/FT2008-R1 FT2009-U1/FT2009-R1
·For Canadian applications, the “FT2008-U1”/“FT2008-R1”/“FT2009-U1”/“FT2009-R1” are deemed supplementary and
can be used for display only. It must be housed in a ULC-S527 approved, locked, enclosure.
·Not approved for UL/ULC MNS applications.
Issued by
Siemens Industry, Inc.
Building Technology Division
8 Fernwood Road
Florham Park, NJ 08932
Tel. +1 973-593-2600
www.sbt.siemens.com/FIS
@2016 Siemens Industry, Inc.
Technical specifications and availability subject to change without notice.
Doc No. A6V10456397_enUS_c 101590209
Edition 2016-06-16
Intended use
The FT2008/FT2009 LED annunciator enables the fire
detection system to be displayed and operated in a
simplified way. The FT2008 provides 2×16 LEDs to
display alarm/trouble events. The FT2009 provides 2×32
LEDs to display alarm/trouble events. Both devices are
operated on the UFP line.
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received,
including interference that may cause undesired operation.
Package contents
The following are included in the scope of delivery:
lFT2008-U1/FT2008-R1 or FT2009-U1/FT2009-R1
lCable ties (2 pcs)
lEOL jumper connecter (1 pcs)
Safety instructions
Risk of injury to persons and damage to property
Please observe the following safety instructions:
l
The devices are only intended for stationary installation
in dry rooms.
lThe devices may only be connected to the UFP line.
lIf panel AUX power is not used, an UL listed/recognized
for fire use, regulated, power limited 24V DC power
supply is required.
lStatic discharge precautions should be taken when
handling the FT2008/FT2009.
Legend
1Stub for mounting cover (2 pcs.)
2 Shield terminal
3 Earth ground terminal
4 Mounting holes (8 pcs.)
5 Cable tie point
6 Breakout openings for cables (2 pcs.)
7 Holes for hanging front panel over stub (2 pcs.)
8 Dip-switch
9 Screws (2 pcs.)
10 EOL jumper
11 Connection terminals for UFP line and power supply
12 Front panel earth ground connection
Mounting instruction
1. Break out the required cable openings (6) on the
backbox.
2. Mark the drilling points for the 3 mounting holes (4), drill
the holes and insert the anchors (not supplied); or use
the pre drilled mounting holes for installation on a 2
gang, or 4” square standard electrical box.
3. Pull the cables for the UFP and power supply, through
the breakout openings (6) on the backbox.
4. Screw the backbox tightly in place.
5. Connect the cable to the terminal (11) in accordance
with the connection diagram.
6. Configure Dip-switch (8) and EOL jumper (10).
7. Connect the green earth ground cable from front panel
(12) to backbox (3).
8. Hook the front panel with the holes (7) over the stubs (1)
on the backbox.
9. Press the front panel down over the backbox, screw (9)
upwards and fix the front panel in place.
Dip-switch
8-digit Dip-switch is used for setting address and baud rate.
The first 1-4 digits are for setting address, the 7-8 digits are
for setting UFP communication baud rate. The 5-6 digits are
reserved for future use.
Add. Dip-switch Baud Rate Dip-switch
1 2 3 4 7 8
1On Off Off Off 9600 bps Off Off
2 Off On Off Off 19200 bps On Off
3 On On Off Off 38400 bps Off On
4 Off Off On Off 57600 bps On On
5On Off On Off
6 Off On On Off
7 On On On Off
8 Off Off Off On
Technical data
FT2008 FT2009
Weight 2.646 lb 3.748 lb
Dimensions (W x H x D)
(In: inch)
8.110x7.362
x1.949
11.417x7.362
x1.949
Storage temperature 14…140 °F
Operating temperature 32…120.2 °F
Humidity ≤93% rel.
Housing IP30
Operating voltage 24V DC Nominal
18.8…27.2V DC
Operating current 25 mA 25 mA
Activation current 65 mA 105 mA

This manual suits for next models

3

Other Siemens Measuring Instrument manuals

Siemens SITRANS F FS200 Utility Owner's manual

Siemens

Siemens SITRANS F FS200 Utility Owner's manual

Siemens Sitrans F Series User manual

Siemens

Siemens Sitrans F Series User manual

Siemens SEM3 User manual

Siemens

Siemens SEM3 User manual

Siemens FIDAMAT 6 User manual

Siemens

Siemens FIDAMAT 6 User manual

Siemens SBT WD2005 User manual

Siemens

Siemens SBT WD2005 User manual

Siemens SITRANS WS100 User manual

Siemens

Siemens SITRANS WS100 User manual

Siemens ASZ7.5 User manual

Siemens

Siemens ASZ7.5 User manual

Siemens SD 270 User manual

Siemens

Siemens SD 270 User manual

Siemens LMS SCADAS XS User manual

Siemens

Siemens LMS SCADAS XS User manual

Siemens SITRANS FUP1010 User manual

Siemens

Siemens SITRANS FUP1010 User manual

Siemens airanger DPL PLUS User manual

Siemens

Siemens airanger DPL PLUS User manual

Siemens UH50 Series User manual

Siemens

Siemens UH50 Series User manual

Siemens Maxum II User manual

Siemens

Siemens Maxum II User manual

Siemens Sitrans F Series User manual

Siemens

Siemens Sitrans F Series User manual

Siemens 9700 User manual

Siemens

Siemens 9700 User manual

Siemens SITRANS F FC410 User manual

Siemens

Siemens SITRANS F FC410 User manual

Siemens Sitrans F Series User manual

Siemens

Siemens Sitrans F Series User manual

Siemens SENTRON PAC2200 User manual

Siemens

Siemens SENTRON PAC2200 User manual

Siemens SITRANS F Administrator guide

Siemens

Siemens SITRANS F Administrator guide

Siemens SITRANS L User guide

Siemens

Siemens SITRANS L User guide

Siemens FS720 Series Operating instructions

Siemens

Siemens FS720 Series Operating instructions

Siemens SITRANS DA400 User manual

Siemens

Siemens SITRANS DA400 User manual

Siemens SITRANS F FX330 User manual

Siemens

Siemens SITRANS F FX330 User manual

Siemens Synova FC330A User manual

Siemens

Siemens Synova FC330A User manual

Popular Measuring Instrument manuals by other brands

NKT Photonics Koheras ADJUSTIK Product guide

NKT Photonics

NKT Photonics Koheras ADJUSTIK Product guide

Extech Instruments CO10 user guide

Extech Instruments

Extech Instruments CO10 user guide

Endress+Hauser Micropilot S FMR530 operating instructions

Endress+Hauser

Endress+Hauser Micropilot S FMR530 operating instructions

Stabila REC 500 RG operating instructions

Stabila

Stabila REC 500 RG operating instructions

Dinamica Generale X-NIR Operator's manual

Dinamica Generale

Dinamica Generale X-NIR Operator's manual

Circutor AR5-L quick start guide

Circutor

Circutor AR5-L quick start guide

Avisoft ULTRASOUND GATE user guide

Avisoft

Avisoft ULTRASOUND GATE user guide

Campbell 107 instruction manual

Campbell

Campbell 107 instruction manual

Callaway EZ manual

Callaway

Callaway EZ manual

AXE MCHH Series Operation manual

AXE

AXE MCHH Series Operation manual

Apera EC60 quick start guide

Apera

Apera EC60 quick start guide

Würth Master LS 2 operating instructions

Würth

Würth Master LS 2 operating instructions

Milwaukee 2217-40 Original instructions

Milwaukee

Milwaukee 2217-40 Original instructions

Keysight Technologies M8131A user guide

Keysight Technologies

Keysight Technologies M8131A user guide

TFA 30.5056.54 instruction manual

TFA

TFA 30.5056.54 instruction manual

Transcat ThermCal130 instruction manual

Transcat

Transcat ThermCal130 instruction manual

SPECTRO SPECTROCUBE C XEP06C Original operating instructions

SPECTRO

SPECTRO SPECTROCUBE C XEP06C Original operating instructions

Ocean Instruments SoundTrap ST500 user guide

Ocean Instruments

Ocean Instruments SoundTrap ST500 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.