4
1. Marking depth is too shallow or deep
Cause: Marking punch ring is not adjust-
ed properly.
Solution: Change setting (See figure 8 ).
Clockwise will decrease and
counter clockwise will increase
the punching pressure.
2. Text is marked in an area not selected with
the dial.
Cause: The data registered on the infor-
mation screen regarding slide
number is different than the box
selected from the dial.
Solution: Check the box selected on the dial
and verify the same slide number
is selected on the information
screen. If not change this slide
number with the + or - key.
3. When marking, the
object moves from the
original position, the
object is not being held
tightly, the object will
not fit in the clamp cor-
rectly.
Cause: The object is
not being held
correctly.
Solution: Ensure that
the lateral
adjustment
clamp is
positioned properly. If not,
loosen the locking knob and
adjust accordingly (See Fig. 9).
Also check that the vertical jaw
slide is in the correct position.
For more clearance loosen the
knob (F) and reposition (See Fig.
10). Make sure knob (F) is tight
before marking.
4. Unreadable text
Cause: Autoformat is not selected.
Solution: Check to see if the Autoformat
option located on the general
information screen is selected
(Marked with an X). If not, select
it to ensure that scaling will occur.
5. When preparing to Mark object, the display
reads, “Marking in Progress, Clamp out of
position”.
Cause: Clamp is in the forward (tracking
position).
Solution: Push clamp to the back (marking
position).
Troubleshooting Guide
Fig. 8
Fig. 9
Fig. 10
USA: 400 Jeffreys Rd., P.O. Box 2627, Rocky Mount, NC 27802-2627 • Tel.: (252) 446-3321 • FAX: (252) 446-4702
Canada: 7301 Decarie Blvd., Montreal, Que. H4P 2G7 • Tel.: (514) 735-5411 • FAX: (514) 735-8707Form No. 2442/E/997-X