DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388 E-mail: [email protected]
www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
11/10/19 INS376 MESH-HBND (Issue 03)
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
NOTE: MESH-
HBND
is compatible with any qualified Bluetooth mesh components and commissioning tools.
We recommend Silvair Commissioning as a reliable solution.
MESH-HBND
Ceiling High Bay (Narrow) Passive Infra Red
(PIR) Occupancy Detector & Photocell
Input: 100-240 Vac 50/60Hz
Ceiling High Bay (Narrow) Passive Infra Red
This MESH-HBND High Bay (Narrow Detection)
Lighting Control can be mounted directly onto
solid ceilings or onto a range of different mounting
boxes. Configurable for any room occupancy
style, via the Silvair Platform (App and Web).
INSTALLATION
To be installed by a competent person with
reference to BS 7671 or equivalent local
standards. If in doubt consult a qualified
electrician.
• Plan where the MESH-HBND is to be located
(see diagram 1). Switch off supply and check
for hidden cables and pipes.
• The MESH-HBND should be connected as
shown in diagram 2:
L - Live in. N - Neutral in.
•
Knockout or drill the appropriate holes on the
mounting plate for attaching the plate to the
ceiling or back box (if applicable). Feed cables
through the appropriate (side or rear) entry hole.
Screw the back mounting plate to the ceiling or
back box via the mounting holes. Wire the cables
into the sensor head block terminal. Push the
sensor head onto the mounting plate and align
the side clips with the slots on the sensor heads.
OPERATION
To check the operation of the MESH-HBND:
• Turn on the supply then after 20 seconds if the
sensor has recognised movement of a person
within its zone of detection the integral red
LED on MESH-HBND will stay illuminated for 4
seconds before the red LED turns off.
• Thereafter, every time movement is detected
by MESH-HBND the integral red LED will stay
illuminated for 4 seconds.
The control also features adjustable time out (time
lag) control and daylight threshold control which
are configured by the Silvair APP.
PRECAUTIONS
• Do not place the MESH-HBND near heat
sources, fans or in ventilated ceiling voids.
• MESH-HBND can be wired in parallel (sharing
the same Live and Neutral).
• Do not place close to, or positioned such
that, any light source points directly into the
MESH-HBND.
• Ensure wires and cables are securely held
within the connection terminals.
• The MESH-HBND should be protected by a 5
or 6 Ampere mcb or fuse.
• Disconnect the MESH-HBND from the
circuit before performing insulation testing
of the wiring circuit.
TECHNICAL DETAILS
INPUT
Voltage: 100 - 240Vac
Frequency: 50/60Hz
Max. mains current: 20mA
Standby current: 14mA
RADIO TRANSCEIVER
Operating frequencies: 2.4... 2,483 GHz
Max. output power: +4 dBm
LUX PARAMETERS
Range: 5 - 2000 lux
OPERATING CONDITIONS
Note: The temperature difference between the
detection target and the background must be
at least 4 °C.
Ambient temperature: -20... +40 °C (lout
20mA)
Storage temperature: -25... +75 °C
Max. relative humidity: 0... 80%, non cond.
CONNECTORS
Terminal block
Wire size:
0.5mm2- 2.5mm2
solid or stranded
Wire strip length: 6-7mm
Tightening torque: 0,4 Nm/4 Kgf.cm
MECHANICAL DATA
Dimensions: 63mm x 91mm x
91mm
Weight: 113g (unpacked)
Degree of protection: IP20
Protection class: Built-in Class 2
Material (casing) Flame-retardant
polycarbonate
Finish / Colour Matt /White (RAL
9003)
Protection class: Built-in Class 2
CONFORMITY AND STANDARDS
EMC emission:
EN 301 489-1 V2.2.0,
EN 301 489-17 V3.1.1,
EN 55032: 2015,
EN61000-3-2: 2014,
EN61000-3-3: 2013
EMC immunity:
EN 301 489-1 V2.2.0, EN 301 489-17 V3.1.1
Environment:
Complies with WEEE and RoHS directives
CB scheme:
IEC60669-1:1998,
IEC60669-1:1998/AMD1:1999,
IEC60669-1:1998/AMD2:2006,
IEC60669-2:2002,
IEC60669-2-1:2002/AMD1:2008,
DIAGRAM 1
Suggested typical wiring
N
L
230 Vac
5A or 6A MCB
or fuse
L
N
N
L
L - Live in. N - Neutral in.
Two neutral and two live terminals
are available for easy ‘loop in’ and
‘loop out’ connection.
DIAGRAM 2
Up to 5m
diameter
Up to 3m
NARROW
DETECTION (ND)
Mounting height
up to 12m
Perspective view -
ceiling mounted
Up
to
15m
SPOT
DETECTION (SP)
Mounting height
up to 20m
Perspective view -
ceiling mounted
Up to 28m
diameter
WIDE
DETECTION (WD)
Mounting height
up to 14m
Perspective view -
ceiling mounted
5 YEAR WARRANTY
MESH-HBND comes with a 5 year
warranty from the date of manufacture
and is CE marked.
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388 E-mail: [email protected]
www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
11/10/19 INS376 MESH-HBND (Issue 03)
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
NOTE: MESH-
HBND
is compatible with any qualified Bluetooth mesh components and commissioning tools.
We recommend Silvair Commissioning as a reliable solution.
MESH-HBND
Ceiling High Bay (Narrow) Passive Infra Red
(PIR) Occupancy Detector & Photocell
Input: 100-240 Vac 50/60Hz
Ceiling High Bay (Narrow) Passive Infra Red
HALL EFFECT / FACTORY RESET:
This function allows a reset to be carried out in order to restore the default
factory settings.
A factory reset will change the state of MESH-HBND from ‘provisioned’
to ‘unprovisioned’, i.e. all network settings will be lost. This functionality is
required to allow reprovisioning MESH-HBND where control over the device
is not functioning correctly.
TO REPROVISION:
Place a small magnet on the site of the Reset / Hall effect sensor (see
diagram 4 below). To trigger the reset the magnet must be held in position
for 5 seconds.
STATUS LED BLINKING SEQUENCE:
MESH-HBND Unprovisioned: 30ms ON 300ms OFF
MESH-HBND Provisioned: 15ms ON 2000ms OFF
Factory Reset: 500ms ON 1000ms OFF
Factory Reset (initial burst): 100ms ON 1000ms OFF
MESH package received: 30ms ON 50ms OFF
Attention (from network): 500ms ON 500ms OFF
DIMENSIONS
DIAGRAM 3
plan side
63
90
90
76
RESET ZONE
(behind moulding). Magnet
to be placed over the Reset
Sticker for reprovisioning.
STATUS LED.
Flashes rapidly when
unprovisioned. Flashes
slowly when provisioned.
DIAGRAM 4

Other Silvair Lighting Equipment manuals

Silvair MESH-HBWD User manual

Silvair

Silvair MESH-HBWD User manual

Silvair MESH-CESR User manual

Silvair

Silvair MESH-CESR User manual

Silvair DG559MB04A1A01 Product manual

Silvair

Silvair DG559MB04A1A01 Product manual

Silvair MESH-HBWD IP66 Series User manual

Silvair

Silvair MESH-HBWD IP66 Series User manual

Silvair MESH-CEFL User manual

Silvair

Silvair MESH-CEFL User manual

Silvair DG558MA04D1A01 Product manual

Silvair

Silvair DG558MA04D1A01 Product manual

Silvair MESH-HBND IP66 Series User manual

Silvair

Silvair MESH-HBND IP66 Series User manual

Silvair MESH-CEDRP User manual

Silvair

Silvair MESH-CEDRP User manual

Silvair MESH-CEDRPLR User manual

Silvair

Silvair MESH-CEDRPLR User manual

Silvair MESH-HBSP IP66 Series User manual

Silvair

Silvair MESH-HBSP IP66 Series User manual

Popular Lighting Equipment manuals by other brands

REMKO SLE Series Assembly and operating instructions

REMKO

REMKO SLE Series Assembly and operating instructions

Lightolier Lytespan 23S70T6 specification

Lightolier

Lightolier Lytespan 23S70T6 specification

Larson Electronics VPLHL-7WLED-PC-GR30 instruction manual

Larson Electronics

Larson Electronics VPLHL-7WLED-PC-GR30 instruction manual

Metabo BSA 18 LED 5000 DUO-S Original instructions

Metabo

Metabo BSA 18 LED 5000 DUO-S Original instructions

JONATHAN Y JYL4007A instructions

JONATHAN Y

JONATHAN Y JYL4007A instructions

American DJ Electra 250 User instruction

American DJ

American DJ Electra 250 User instruction

B-K lighting CORE DRILL installation instructions

B-K lighting

B-K lighting CORE DRILL installation instructions

Viatek LL03-RG-MOV-R instructions

Viatek

Viatek LL03-RG-MOV-R instructions

Robin Robin Cyclone user manual

Robin

Robin Robin Cyclone user manual

MULTIQUIP GloBug GB113BC Operation and parts manual

MULTIQUIP

MULTIQUIP GloBug GB113BC Operation and parts manual

Avlite AV-OL-KT-A1 Installation & service manual

Avlite

Avlite AV-OL-KT-A1 Installation & service manual

Luraco L1004B-KP-V3 user manual

Luraco

Luraco L1004B-KP-V3 user manual

PR Lighting AQUA 580 BWS manual

PR Lighting

PR Lighting AQUA 580 BWS manual

Lightolier Lytespan 9376 specification

Lightolier

Lightolier Lytespan 9376 specification

Soundoff Signal BOLT2 manual

Soundoff Signal

Soundoff Signal BOLT2 manual

Saxby Lighting 73666 Instruction leaflet

Saxby Lighting

Saxby Lighting 73666 Instruction leaflet

TeSuCo Sparki SPT031 instructions

TeSuCo

TeSuCo Sparki SPT031 instructions

Simx Lighting LHT0251 installation instructions

Simx Lighting

Simx Lighting LHT0251 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.