manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Silvair
  6. •
  7. Lighting Equipment
  8. •
  9. Silvair MESH-HBSP IP66 Series User manual

Silvair MESH-HBSP IP66 Series User manual

PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
NOTE: MESH-
HBSP IP66
is compatible with any qualified Bluetooth mesh components and commissioning tools.
We recommend Silvair Commissioning as a reliable solution.
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388 E-mail: [email protected]
www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
11/10/19 INS380 MESH-HBSP IP66 (XX) (Issue 03)
MESH-HBSP IP66 (XX)
IP66 Rated Ceiling High Bay (Spot) Passive
Infra Red (PIR) Occupancy Detector & Photocell
Input: 100-240 Vac 50/60Hz
This MESH-HBSP IP66 High Bay (Spot Detection)
Lighting Control has an IP66 rated weatherproof
enclosure and can be ceiling mounted.
Configurable for any room occupancy style, via the
Silvair Platform (App and Web).
INSTALLATION
To be installed by a competent person with
reference to BS 7671 or equivalent local standards.
If in doubt consult a qualified electrician.
• Plan where the MESH-HBSP IP66 is to be
located (see diagram 1). Switch off supply and
check for hidden cables and pipes.
• Remove the front cover by quarter turning the
four quick release fasteners to the ‘0’ position
(see diagram 4 overleaf).
• Mount the back section of the mounting box in
the required location via the 4 corner holes.
• Thread mains cable carefully through the
required membrane entry point.
• Unclip the internal back plate. Remove the
required knock out if replacing the optional
internal back plate.
• Thread mains cable into the unit. The MESH-
HBSP IP66 should be connected as shown in
diagram 2:
L - Live in. N - Neutral in.
• Reclip the internal back plate if required.
• Replace the front cover ensuring the quick
release fasteners are secured in the ‘1’ position.
OPERATION
To check the operation of the MESH-HBSP IP66:
• Turn on the supply then after 20 seconds if the
sensor has recognised movement of a person
within its zone of detection the integral red LED
on MESH-HBSP IP66 will stay illuminated for 4
seconds before the red LED turns off.
• Thereafter, every time movement is detected by
MESH-HBSP IP66 the integral red LED will stay
illuminated for 4 seconds.
The control also features adjustable time out (time
lag) control and daylight threshold control which
are configured by the Silvair APP.
PRECAUTIONS
• Do not place the MESH-HBSP IP66 near heat
sources, fans or in ventilated ceiling voids.
• MESH-HBSP IP66 can be wired in parallel
(sharing the same Live and Neutral).
• Do not place close to, or positioned such
that, any light source points directly into the
MESH-HBSP IP66.
• Ensure wires and cables are securely held within
the connection terminals.
• The MESH-HBSP IP66 should be protected by
a 5 or 6 Ampere mcb or fuse.
• Disconnect the MESH-HBSP IP66 from the
circuit before performing insulation testing
of the wiring circuit.
TECHNICAL DETAILS
INPUT
Voltage: 100 - 240Vac
Frequency: 50/60Hz
Max. mains current: 20mA
Standby current: 14mA
RADIO TRANSCEIVER
Operating frequencies: 2.4... 2,483 GHz
Max. output power: +4 dBm
LUX PARAMETERS
Range: 5 - 2000 lux
OPERATING CONDITIONS
Note: The temperature difference between the
detection target and the background must be at
least 4 °C.
Ambient temperature: -20... +40 °C (lout
20mA)
Storage temperature: -25... +75 °C
Max. relative humidity: 0... 80%, non cond.
CONNECTORS
Terminal block
Wire size:
0.5mm2- 2.5mm2solid
or stranded
Wire strip length: 6-7mm
Tightening torque: 0,4 Nm/4 Kgf.cm
MECHANICAL DATA
Dimensions: 110mm x 110mm x
73mm
Weight: 250g (unpacked)
Degree of protection: IP66
Protection class: Built-in Class 2
Material (casing)
Flame-retardant
polycarbonate/
Polypropylene.
Finish / Colour:
WM-HBSP IP66 GY
Matt /Grey
(RAL 7035)
Finish / Colour:
WM-HBSP IP66 WH
White
(RAL 9001)
Finish / Colour:
WM-HBSP IP66 BK
Black
(RAL 9005)
Protection class: Built-in Class 2
CONFORMITY AND STANDARDS
EMC emission:
EN 301 489-1 V2.2.0, EN 301 489-17 V3.1.1,
EN 55032: 2015, EN61000-3-2: 2014,
EN61000-3-3: 2013
EMC immunity:
EN 301 489-1 V2.2.0, EN 301 489-17 V3.1.1
Environment:
Complies with WEEE and RoHS directives
CB scheme:
IEC60669-1:1998, IEC60669-1:1998/AMD1:1999,
IEC60669-1:1998/AMD2:2006, IEC60669-2:2002,
IEC60669-2-1:2002/AMD1:2008,
Suggested typical wiring
N
L
230 Vac
5A or 6A MCB
or fuse
L
N
N
L
L - Live in. N - Neutral in.
Two neutral and two live terminals
are available for easy ‘loop in’ and
‘loop out’ connection.
DIAGRAM 2
DIAGRAM 1
Up to 5m diameter
Up to 3m
Mounting height up to 12m
Perspective view - ceiling mounted
Up
to
15m
Mounting height up to 20m
Perspective view - ceiling mounted
Up to 28m
diameter
Mounting height up to 14m
Perspective view - ceiling mounted
COLOUR OPTIONS
This product is available in 3 colour options
designated by the following product codes:
Grey: MESH-HBSP IP66 GY
White: MESH-HBSP IP66 WH
Black: MESH-HBSP IP66 BK
5 YEAR WARRANTY
MESH-HBSP IP66 (XX) comes with
a 5 year warranty from the date of
manufacture and is CE marked.
PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING THE PRODUCT
NOTE: MESH-
HBSP IP66
is compatible with any qualified Bluetooth mesh components and commissioning tools.
We recommend Silvair Commissioning as a reliable solution.
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388 E-mail: [email protected]
www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
11/10/19 INS380 MESH-HBSP IP66 (XX) (Issue 03)
MESH-HBSP IP66 (XX)
IP66 Rated Ceiling High Bay (Spot) Passive
Infra Red (PIR) Occupancy Detector & Photocell
Input: 100-240 Vac 50/60Hz
Optional
Internal
Back Plate with
knock out options
Mounting
Box with
M20
cable entry
membrane
options.
Front Cover
and
Control Unit
IP66: Using the membrane entry -
cable: 5.2m - 17mm
Optional
Internal
Back Plate with
knock out options
Mounting
Box with
M20
cable entry
membrane
options.
Front Cover
and
Control Unit
IP66: Using the membrane entry -
cable: 5.2m - 17mm
DIAGRAM 5
HALL EFFECT / FACTORY RESET:
This function allows a reset to be carried out in order to restore the default
factory settings.
A factory reset will change the state of MESH-HBSP IP66 from ‘provisioned’
to ‘unprovisioned’, i.e. all network settings will be lost. This functionality is
required to allow reprovisioning MESH-HBSP IP66 where control over the
device is not functioning correctly.
TO REPROVISION:
Place a small magnet on the site of the Reset / Hall effect sensor (see
diagram 4 below). To trigger the reset the magnet must be held in position
for 5 seconds.
DIMENSIONS
RESET ZONE
(behind moulding).
Magnet to be
placed over this
area for
reprovisioning.
DIAGRAM 4
STATUS LED BLINKING SEQUENCE:
MESH-HBSP IP66 Unprovisioned: 30ms ON 300ms OFF
MESH-HBSP IP66 Provisioned: 15ms ON 2000ms OFF
Factory Reset: 500ms ON 1000ms OFF
Factory Reset (initial burst): 100ms ON 1000ms OFF
MESH package received: 30ms ON 50ms OFF
Attention (from network): 500ms ON 500ms OFF
DIAGRAM 3
plan side
110
110 73

This manual suits for next models

3

Other Silvair Lighting Equipment manuals

Silvair MESH-HBWD User manual

Silvair

Silvair MESH-HBWD User manual

Silvair MESH-CEDRP User manual

Silvair

Silvair MESH-CEDRP User manual

Silvair DG558MA04D1A01 Product manual

Silvair

Silvair DG558MA04D1A01 Product manual

Silvair MESH-CEDRPLR User manual

Silvair

Silvair MESH-CEDRPLR User manual

Silvair MESH-HBND User manual

Silvair

Silvair MESH-HBND User manual

Silvair MESH-HBND IP66 Series User manual

Silvair

Silvair MESH-HBND IP66 Series User manual

Silvair DG559MB04A1A01 Product manual

Silvair

Silvair DG559MB04A1A01 Product manual

Silvair MESH-CESR User manual

Silvair

Silvair MESH-CESR User manual

Silvair MESH-CEFL User manual

Silvair

Silvair MESH-CEFL User manual

Silvair MESH-HBWD IP66 Series User manual

Silvair

Silvair MESH-HBWD IP66 Series User manual

Popular Lighting Equipment manuals by other brands

Chauvet Professional Maverick Silens 2 Profile user manual

Chauvet Professional

Chauvet Professional Maverick Silens 2 Profile user manual

Kichler Lighting 16022 instructions

Kichler Lighting

Kichler Lighting 16022 instructions

Defiant HD-1870-BZ Use and care guide

Defiant

Defiant HD-1870-BZ Use and care guide

CyberData 011490 Installation quick reference

CyberData

CyberData 011490 Installation quick reference

BAYLED TETRA PRL-2 RGB installation guide

BAYLED

BAYLED TETRA PRL-2 RGB installation guide

Tekky MOURNING GORY Installation and operating instructions

Tekky

Tekky MOURNING GORY Installation and operating instructions

SLV Elektronik 146050 operating manual

SLV Elektronik

SLV Elektronik 146050 operating manual

VitaLight 40600150 user manual

VitaLight

VitaLight 40600150 user manual

Dialight L-856 Installation and maintenance manual

Dialight

Dialight L-856 Installation and maintenance manual

Chauvet Abyss LED 3.0 user manual

Chauvet

Chauvet Abyss LED 3.0 user manual

SGM Hazer 400 quick start guide

SGM

SGM Hazer 400 quick start guide

NORDRIDE 2078 operating instructions

NORDRIDE

NORDRIDE 2078 operating instructions

Monzana GHEZ001 instructions

Monzana

Monzana GHEZ001 instructions

ML Accessories EMPDL Installation & maintenance manual

ML Accessories

ML Accessories EMPDL Installation & maintenance manual

ALS RB/IN-WW(L)-C instruction manual

ALS

ALS RB/IN-WW(L)-C instruction manual

Snowball SB5-SM installation instructions

Snowball

Snowball SB5-SM installation instructions

King Technology Pool Frog 6100 instruction manual

King Technology

King Technology Pool Frog 6100 instruction manual

ML Accessories WAD12AA Installation & maintenance manual

ML Accessories

ML Accessories WAD12AA Installation & maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.