-9-
Caution
(2) Connection of the metal rod accessories
Do not use tube, resin plug, reducer, etc. after
connecting a fitting with a metal rod (KC series,
etc.) to a One-touch fitting. This can cause the
disconnection of tube.
(3) When mounting the tube, resin plug or metal
rod, do not press the release button.
Do not press the release button unnecessarily
before mounting tubing, resin plugs and metal
rods. This can cause the disconnection of tube.
(4) When using a tubing other than from SMC,
confirm that the tube material and the O.D.
accuracy satisfy the following specifications.
1) Nylon tube ±0.1 mm max.
2) Soft nylon tube ±0.1 mm max.
3) Polyurethane tube +0.15 mm at max.
Within -0.2 mm
Do not use the tubing which does not satisfy the
specified tubing O.D. accuracy, or if the tubing
has a different I.D., material, hardness, or
surface roughness from those of SMC's tubing.
If you have any questions, please consult SMC.
Failure to satisfy the specifications may lead to
difficulty in connecting the tubing, leakage,
disconnection of the tubing, or fitting damage.
(1) When connecting piping to the One-touch
fitting, use a pipe length with sufficient
margin, in accordance with the piping
conditions shown in Figure 1.
Also, when using a tying band, etc., to bind the
piping together, make sure that external force
does not come to bear on the fitting.
(see Figure 2)
Unit:mm
φ4, φ5/32"
56 or more 44 or more 26 or more 20 or more
φ6
84 or more 66 or more 39 or more 30 or more
φ1/4"
89 or more 70 or more 57 or more 32 or more
φ8, φ5/16”
112 or more 88 or more 52 or more 40 or more
φ10
140 or more 110 or more 69 or more 50 or more
φ12
168 or more 132 or more 88 or more 60 or more
Tubing size Straight-line
length
Mounting pitch A
Nylon
tube
Soft nylon
tube
Polyurethane
tube
Warning
(1) Type of fluids
Please consult with SMC when using the
product in applications other than compressed
air.
(2) When there is a large amount of drainage
Compressed air containing a large amount of
drainage can cause the malfunction of
pneumatic equipment. An air dryer or water
separator should be installed upstream from
filters.
(3) Drain flushing
If condensation in the drain bowl is not emptied
on a regular basis, the bowl will overflow and
allow the condensation to enter the compressed
air lines. This causes the malfunction of
pneumatic equipment.
If the drain bowl is difficult to check and remove,
the installation of a drain bowl with an auto drain
option is recommended.
For compressed air quality, refer to SMC catalog
"Compressed Air Purification System".
(4) Use clean air
Do not use compressed air that contains
chemicals, synthetic oils that include organic
solvents, salt, corrosive gases, etc., as it can
cause damage or malfunction.
Caution
(1) Install an air filter.
Install an air filter upstream near the valve.
For the filtration rating, select 5 μm or below, or
select a rating equivalent to or lower than ISO
8573-1:2010 [6:4:4]
*
.
*This is equivalent to the filtration performance
achieved when an air filter is attached for inlet
side compressed air with purity class of [7:4:4].
(2) Ensure that the fluid and ambient
temperatures are within the specified range.
If the fluid temperature is 5
℃
or less, the
moisture in the circuit could freeze, causing
damage to the seals or leading to equipment
malfunction. Therefore, take appropriate
measures to prevent freezing.
For compressed air quality, refer to SMC catalog
"Compressed Air Purification System".
Recommended Piping Conditions
Piping
Air Supply