¡Peak/Bottom value display function
The maximum (minimum) pressure up to now from the power ON
is detected to update the data. This pressure is displayed in the
peak (bottom) value display mode. In the peak value display
mode, keep the button pressed for 1 second or longer to blink
the maximum pressure value and hold it. To cancel the hold dis-
play, keep the button pressed for 1 second or longer again. In
the bottom value display mode, keep the button pressed for 1
second or longer to blink the minimum pressure value and hold it.
To cancel the hold display, keep the button pressed for 1 sec-
ond or longer again. Keep the and buttons pressed at the
same time for 1 second or longer during hold display to initialize
the maximum (minimum) pressure value.
¡Zero-clear function
The display value can be adjusted to zero when the pressure to
be measured is within the range of ±10%F.S. from the factory de-
fault setting.
(Due to individual product differences, the zero-clear range varies
±1 digit.)
Keep the and buttons pressed at the same time for 1 sec-
ond or longer to reset the display value to zero.
The mode then returns to the measurement mode automatically.
¡Keylock function
This function prevents incorrect operations such as accidentally
changing the set-value. If any button is operated when the key is
locked, “LoC” is displayed for approx. 1 sec.
zKeep the button pressed for 5 seconds or
longer in the measurement mode.
The current setting “LoC” or “UnL” is displayed.
(Perform the same operation when unlocking the
key.)
xPress the or button to select “Lock” or “Unlock”.
cPress the button to set the selection.
•Lock setting
zKeep the button pressed for 5 seconds or
longer in the measurement mode.
“UnL” is then displayed.
xPress the or button to select the lock “LoC”.
cPress the button to set the selection.
•Unlock setting
zKeep the button pressed for 5 seconds or
longer in the measurement mode.
“LoC” is then displayed.
xPress the or button to select the unlock
“UnL”.
cPress the button. You are prompted to enter
the security code.
For details about how to enter the security code,
refer to “Security code entering/changing proce-
dure” described below.
vWhen the secret code is correct, “UnL” is displayed. Press
any of the , , and buttons. The key is unlocked
to return to the measurement mode.
If the security code is incorrect, “FAL” is displayed and you are
prompted to enter the security code again. If the security code
entry is continuously failed three times, “LoC” is displayed to
return to the measurement mode.
<Operating procedure - Security code is not used.>
<Operating procedure - Security code is used.>
Changing of security code
With the factory default settings, the security code is set at “000”,
but it can be changed to a desired value.
zMake the lock setting (described on the left). After setting,
make the unlock setting (steps zto cshown above).
xWhen “UnL” is displayed, keep the and buttons pressed
at the same time for 5 seconds or longer. “000” is displayed,
and then you are prompted to change the security code.
For details about how to enter the security code, refer to “Se-
curity code entering/changing procedure” described below.
After a desired security code has been entered completely, the
set security code is displayed.
cAfter checking, press the button.
The mode returns to the measurement mode.
At this time, when pressing the or button, the security
code is not changed and you are prompted to change the se-
curity code again.
<Operating procedure>
Other Settings
Air-blow Module Series LLB1
or
or
LockedUnlocked
or
or
LockedUnlocked
or
or
LockedUnlocked
¡
Security code entering/changing procedure
The 1st digit starts blinking.
Press the or button to set the numeric
value.
Press the button. The numeric value at the
next digit starts blinking. (When pressing the
button at the most significant digit, the 1st
digit then starts blinking.)
After a desired security code has been en
tered
completely, keep the button pressed
for 1
second or longer.
(If no key is operated for 30 seconds or longer dur-
ing security code entry/change operation, the mode
will return to the measurement mode automatically.)
341