Solar Stik 24VDC PRO-VERTER 5000-220 AGS Installation manual

|1March 2020 |Solar Stik®, Inc.
REPROGRAMMING INSTRUCTIONS
FOR
24VDC PRO-VERTER 5000-220 AGS
SETTINGS, FAVS & PIN
Effective Date: 20200303

24VDC PRO-Verter 5000-220 Reprogramming Instructions
March 2020 |Solar Stik®, Inc.2 |
Entering the SETUP Menu When the PIN Is Set and Locked
A PIN has been set and the SETUP button menus are locked when the SETUP button is pressed and
the “Enter SETUP PIN = 0***” menu appears on the screen. The correct/original PIN (2014) must be
entered to access the menu. If the incorrect PIN is entered, “Invalid PIN” displays. There is no limit to
how many attempts can be made to enter the correct PIN.
To enter an existing PIN (from the Enter SETUP PIN = 0*** menu):
1. Rotate the SELECT knob to the correct digit, and then press the knob.
2. Repeat Step 1 to enter the remaining three digits of the existing PIN.
3. After pressing the SELECT knob for the last digit, access to the SETUP menu is permitted.
Info: After the correct PIN has been entered, there is no need to reenter it to access another protected
menu—unless ve (5) minutes have passed without any button push.
Changing an Existing PIN
The PIN can be changed at any time. First, go to the TECH: 05 SETUP PIN menu and then enter the
existing PIN to access the “Change PIN” menu item.
To change an existing PIN (from the 05 SETUP PIN menu):
1. Use the SELECT knob to enter the existing PIN (see procedure above).
2. After the existing PIN is entered and SELECT has been pressed for the last digit, the “Set SETUP”
options menu appears.
3. Rotate the SELECT knob to the “Change PIN” option, and then press the SELECT knob. The “Set
SETUP PIN” menu appears with the current PIN displayed and the rst PIN digit blinking.
4. Enter a new four-digit PIN. Note: The number “0000” is not an option.
5. After pressing the SELECT knob for the last digit, the new PIN is set. The display will return to the
“Set SETUP PIN” menu where the SETUP button menus may be “locked/unlocked.
Resetting the PRO-Verter 5000 PIN
Access to critical PRO-Verter program settings is
protected by a personal identication number (PIN).
The PIN set at the Solar Stik Factory is the year
that is printed on the I-Plate, which corresponds
to the year that the PRO-Verter was manufactured.
The PIN can be changed to to any other suitable,
secure, four-digit number.
PSS-G Tower
PSS-G ALTERNATIVE ENERGY SYSTEM (AES) CONFIGURATION
24VDC Interconnect Strip 7
24VDC PRO-Verter 7000
24VDC Power Hub 2400
MEP-802A 5kW TQG
24VDC
Li Expander Pak 2400 (4)
PAMs (6)
(3) 24VDC Port
24VDC
Li Expander Pak 2400 (3)
24VDC Interconnect Strip 7
AC Input (P1)
Example of an Inset from the lower right corner
of the PRO-Verter I-Plate. This number may may
vary.
Please record the PIN chosen in a secure location for future reference.
Overriding an Unknown PIN
A previously-entered PIN can be overridden. When “PIN = 0***” displays, press and hold the SELECT
knob until “PIN = 0000” displays (approximately 7 seconds). Enter a new PIN number.

|3March 2020 |Solar Stik®, Inc.
24VDC PRO-Verter 5000-220 Reprogramming Instructions
How to reprogram settings in the PRO-Verter SETUP menus
Use the PIN-code to access the programmable settings in the SETUP menus.
Use the PRO-Verter Menu Map provided in the SYSTEM SETUP AND OPERATION MANUAL FOR
ATSC MS3 L0 as a guide for entering the proper settings. Cycle the power on the PRO-Verter and
conrm that all changes were saved.
1. Program FAVS F1 Menu for BATTERY TYPE
a. Press the SETUP Menu button.
b. Scroll to 03 Charger Setup; press the SELECT knob.
c. Scroll to 03C Battery Type; press the SELECT knob.
d. Scroll to “CC/CV”.
e. Push and hold the FAVS button for three seconds.
i. The screen will display “Select FAV: F1”.
f. Press the SELECT knob to save 03C Battery Type CC/CV to FAVS F1.
2. Program FAVS F2 Menu for AMPHOUR SIZE
a. Press the SETUP Menu button.
b. Scroll to 05 BMK Setup; press the SELECT knob.
c. Scroll to 05B AmpHour Size.
d. Push and hold the FAVS button for three seconds.
i. The screen will display “Select FAV: F1”.
e. Scroll to F2. Press the SELECT knob to save 05B AmpHour Size to FAVS F2.
3. Program FAVS F3 Menu for AC INPUT
a. Press the SETUP Menu button.
b. Scroll to 03 Charger Setup; press the SELECT knob.
c. Display will show 03A AC Input.
d. Push and hold the FAVS button for three seconds.
i. The screen will display “Select FAV: F1”.
e. Scroll to F3. Press the SELECT knob to save 03A AC Input to FAVS F3.
4. Program FAVS F4 Menu for LBCO SETTING
a. Press the SETUP Menu button.
b. Scroll to 02 Inverter Setup; press the SELECT knob.
c. Scroll to 02B LBCO Setting.
d. Push and hold the FAVS button for three seconds.
i. The screen will display “Select FAV: F1”
e. Scroll to F4. Press the SELECT knob to save 02B LBCO Setting to FAVS F4.
5. Program FAVS F5 Menu for GEN RUN VDC
a. Press the SETUP Menu button.
b. Scroll to 04 AGS Setup; press the SELECT knob.
c. Scroll to 04A Gen Run VDC.
d. Push and hold the FAVS button for three seconds.
i. The screen will display “Select FAV: F1”
g. Scroll to F5. Press the SELECT knob to save 04A Gen Run VDC to FAVS F5.
How to program FAVS menu buttons
Table of contents
Other Solar Stik Power Supply manuals

Solar Stik
Solar Stik PRO-VERTER 7000-120 User manual

Solar Stik
Solar Stik G-BOSS E LIGHT User manual

Solar Stik
Solar Stik PRO-VERTER 5000-240 User manual

Solar Stik
Solar Stik USAF G-BOSS Manual instruction

Solar Stik
Solar Stik 24VDC PRO-VERTER 5000-120 AGS User manual

Solar Stik
Solar Stik 24VDC HyPR 3000 Installation instructions

Solar Stik
Solar Stik PRO-VERTER 5000-220 AFF1 User manual

Solar Stik
Solar Stik 24VDC POWER HUB 2500 User manual

Solar Stik
Solar Stik PRO-Verter S 2000 AGS Manual instruction

Solar Stik
Solar Stik 24VDC HyPR 3000 Installation instructions