Speco O5B3M User manual

O5B3M
5
Megapi
Bullet IP Camera
with Motorized Lens
O5B3M
Megapi
xel H.265
with Motorized Lens
& Super IR
& Super IR

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Rev.1.0 (Dec. 2015) 2
Caution
Any changes or modifications in construction of this device which are not explicitly approved by the
party responsible for compliance could void the user’s warranty.
Note
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generate, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into and outlet on a circuit different from that to which the receiver is
connected
Consult the dealer or an experienced radio/TV technician for help.
Directions
Be careful not to cause any physical damage by dropping or throwing the camera. Especially keep the
device out of reach from children.
Do not disassemble the camera. No after service is assumed when disassembled.
Use only power adapters compatible with the unit.
Be careful to prevent moisture or water penetration into the unit. Particular attention is needed when
installing the unit. The screw holes for the installation screws and pipe should be maintained water tight
during the whole life time of the product.
All the electrical connection wires running into the unit should be prepared so that water from the outside
cannot flow into the unit through the surface of the wires. Penetration of the moisture through the wire for
extended period can cause malfunction of the unit or deteriorated image.

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Rev.1.0 (Dec. 2015) 3
Revision History
Date Revision Details
12/15/2015 1.0 Initial version

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Rev.1.0 (Dec. 2015) 4
Contents
1.
Introduction .................................................................................................................................................... 5
1.1.
Overview ............................................................................................................................................... 5
1.2.
Specifications ........................................................................................................................................ 6
2.
Product Description ...................................................................................................................................... 8
2.1.
Contents................................................................................................................................................ 8
2.2.
Product Preview.................................................................................................................................... 8
2.3.
Physical description .............................................................................................................................. 9
2.3.1.
External View .............................................................................................................................. 9
2.3.2.
Dimensions ................................................................................................................................. 9
2.3.3.
External Connector ................................................................................................................... 10
2.3.4.
Factory Default Switch.............................................................................................................. 10
2.4.
Functional Description ........................................................................................................................ 11
3.
On Site Installation ...................................................................................................................................... 13
4.
Getting Started ............................................................................................................................................. 14
4.1.
PC Requirement ................................................................................................................................. 14
4.2.
Quick Installation Guide ...................................................................................................................... 15
4.2.1.
Connect PC and O5B3M to network. ....................................................................................... 15
4.2.2.
Set IP parameters on O5B3M................................................................................................... 15
4.2.3.
Remote video connection to O5B3M ........................................................................................ 16
4.2.4.
Additional settings through connection to the Admin Page ......................................................18
5.
Troubleshooting........................................................................................................................................... 19
5.1.
No power is applied ............................................................................................................................ 19
5.2.
Cannot connect to the Video...............................................................................................................20
5.3.
Technical Assistance........................................................................................................................... 21
Appendix A– Important Notice in Exchanging SD Card (Micro SD)......................................................................... 22

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Rev.1.0 (Dec. 2015) 5
1. Introduction
1.1. Overview
The O5B3M is a 5 megapixel, triple-codec (H.265, H.264, MJPEG) network camera. It enables real time
transmission of synchronized video. Remote clients can connect to the O5B3M for real time video/audio through
PCs and smartphones. Real-time 2-way communication is available through the bidirectional audio
communication feature.
H.265 (HEVC) is a video compression standard that’s a successor to H.264. By using H.265, 40-50% reduction
in bandwidth and storage can be saved at the same visual quality compared to H.264.
In extreme darkness, adaptive, super IR LEDs can be used to illuminate the scene without IR saturation of the
scene.
Designed to be a stand-alone streaming audio & video transmission device, ONSIP O5B3M can be applied to
various application area such as video security, remote video monitoring, distance education, video conference
or internet broadcasting system. .

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Rev.1.0 (Dec. 2015) 6
1.2. Specifications
Camera
Image sensor Progressive scan 1/1.8 inch CMOS 5M pixels
Full resolution 2,592 x 1,944 pixels (5MP)
Sync System Internal
Min. illumination 0.2Lux (Color, DSS On), 0.00Lux (IR LED On)
S/N Ratio 50dB or more
White Balance AWB
DSS Supported
WDR Supported
Lens 3.6 ~ 10mm Motorized Focus & Zoom
Day & Night Supported (TDN, IR LED)
IR range 98 ft (depending on scene reflection)
Video
Compression method Multi Codec (H.265 / H.264 / MJPEG)
Resolution 2,592 x 1,944@30fps
Multi-Profile Streaming - 4 simultaneous video profiles
- Select the codec type, resolution and frame rates for each profile.
Intelligent Bit-Rate Control VBR or CBR
PTZ Digital PTZ & Video crop
Image Setting Text overlay, Privacy mask, De-interlace filter
Motion detection Cell-based configuration
Audio
Mono Upstream 32Kbps G.726 ADPCM, 64Kbps 16bit µ-law PCM ~ MIC/Line-in
Mono Downstream 64Kbps 16bit µ-law PCM ~ Line-out
Network
Network Protocol
- IPv4, TCP, UDP, IGMP, ICMP, ARP, RARP, PPPoE, RTCP
- RTP, RTSP, SDP, HTTP, SMTP, FTP, DHCP, UPnP
- NTP, DNS, DynDNS
Dynamic IP Speco DDNS (free of charge)
Security - User ID & Password protection, IP address filtering
- Digest Authentication, User Access Log
Streaming method
- RTSP streaming with proprietary format for control information
- standard RTSP streaming
- HTTP streaming

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Rev.1.0 (Dec. 2015) 7
External Terminals
LAN 10/100BaseT LAN (auto MDIX)
Analog output 1 channel D1 CVBS output
Alarm input / output Alarm I/O (1 Sensor input & 1 Relay output)
Factory Reset Supported
Audio MIC/Line in, Line out
Power DC 12V input
Alternate Power
Standard PoE IEEE802.3af
Alarm & Event
Intelligent Video Motion Detection
Alarm Triggers Motion Detection + Sensor Input
Alarm Events Video file upload(FTP), Still Image
transmission(Email), Relay output
Alarm Buffer (Audio/Video) Configurable Pre-alarm (5~15 sec) & Post-alarm (10~60 sec)
Miscellaneous
Operating Temperature -4°F ~ 122°F
Operation Humidity 8 ~ 80% RH
Power DC 12V, 0.6A
Dimensions(L x W x H) 10” x 3” x 3.2”
Weight 2.4lbs
Outdoor Rating IP66
Approvals FCC, RoHS
Package information Unit, CD, mounting screws

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
2. Product Description
2.1. Contents
The product package contains
the following
Contents
O5B3M
O5B3M
Accessories
Screws (
L-
type wrench
CD
Software &
Reference Guide
Quick installation guide
2.2. Product Preview
O5B3M
Camera Unit
PC software to allocate an IP
address to the IP Camera
the following
:
Description
Remarks
O5B3M
main unit
Screws (
2 type)
type wrench
(2 type), CVBS Cable
Software &
User’s Guide
Quick installation guide
, Guide pattern
ONSIP Installer
PC software to allocate an IP
address to the IP Camera
Remarks

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Rev.1.0 (Dec. 2015) 9
2.3. Physical description
2.3.1. External View
Figure 2-1. External view of O5B3M
2.3.2. Dimensions
Figure 2-2. Dimensions
Unit: mm

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Rev.1.0 (Dec. 2015) 10
2.3.3. External Connector
Figure 2-3. Connector for external connection
2.3.4. Factory Default Switch
Factory default switch is provided for returning the IP camera to factory default state. The factory default
switch can be found by opening the lower body cap of the camera. There are two functions assigned to
factory default switch.
1. Returning to Factory Default State: Press the switch about 5 seconds while power is applied to
return to factory default state.
2. Safe Removal of Micro-SD Card: Press the switch for 1 second to unmount the Micro SD Card for
safe removal.
Figure 2-4. Factory Default switch and Micro-SD Card slot
Video Output (CVBS)
Factory Default Switch/
Micro SD Card Eject
Micro SD Card Slot
Network (LAN)
Power Mic/Line Input
Line Output
Sensor Input: white(+), Red(-)
Relay Output: Black(+), Yellow(-)

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
2.4. Functional Description
Power:
Power input for supplying
Caution: If O5B3M
is powered by PoE, do not plug in DC Jack with active DC power
into DC power connector.
Network (LAN)
100Mbps Ethernet connector (RJ-
45) with PoE standard (
Micro SD Card slot
Please insert SD memory card when you want to use SD memory
card, please push the SD card.
MIC/Line Input
Connect external audio source or microphone.
Line Output
Connect speakers with built in amplifier. Audio from remote site is output through Line out in bi
audio mode.
Power input for supplying
12V DC power.
is powered by PoE, do not plug in DC Jack with active DC power
into DC power connector.
45) with PoE standard (
IEEE 802.3af).
Please insert SD memory card when you want to use SD memory
card. In case of pulling out SD memory
Connect external audio source or microphone.
Connect speakers with built in amplifier. Audio from remote site is output through Line out in bi
is powered by PoE, do not plug in DC Jack with active DC power
card. In case of pulling out SD memory
Connect speakers with built in amplifier. Audio from remote site is output through Line out in bi
-directional

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Rev.1.0 (Dec. 2015) 12
Sensor Input
Connect external alarm sensor. Examples of sensing devices are infrared sensor, motion sensor,
heat/smoke sensor, magnetic sensor, etc. Connect the two wires of the sensors to “Sensor Input”.
The sensor type (NC/NO) can be set in admin page. Multiple sensor devices can be connected in parallel.
Figure 2-6. SENSOR input and connection of the sensor
Relay Output
Relay output is provided for connecting alarm devices or for remote on/off control of devices such as light.
Relay is normal open and it will be closed upon alarm annunciation or remote on. The relay is capable
of switching 30V AC/DC, 2A. For the application which needs power switching beyond this limit, use
additional relay switch as shown in the right of Figure.
* Left: switching requirement below 30V, 2A
* Right: switching requirement higher than 30V, 2A. Apply this connection when either voltage or
current exceed the limit.
Figure 2-7. RELAY Output connection
Alarm
Out
Device
Power
Supply
( ~30V)
( ~ 2A)
(DC/AC)
Alarm
Out
Device
Power
Supply
(30V~ )
( 2A~ )
(DC/AC)
Optional
Relay
Switch
Power
Supply
( ~30V)
( ~ 2A)
(DC/AC)
Relay
Relay
Photo Coupler NO/NC Type Open Collector Type
Sensor1+
Sensor
Device
Sensor1-
Sensor
Device
Sensor
Power
Supply
Sensor
Power
Supply
GND
+12V

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
3. On Site Installation
Use Cables and conduits that are suitable for the installation and that are compliant to IP66. Particular attention
should be paid in the installation so that no moisture is allowed to penetrate into the unit through the cables or
conduits during the life time of the product. Products of which the internal parts are exposed to moisture
because of improper installation are not covered by warranty.
1. Fix the base on a flat surface.
2. Adjust the rotational position of the camera for desired viewing of the site.

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Rev.1.0 (Dec. 2015) 14
4. Getting Started
Brief information for first time operation of O5B3M is provided in this chapter.
4.1. PC Requirement
Audio/Video streaming data received from O5B3M can be displayed or stored in a PC running client programs.
Minimum requirement of the PC is described below:
ITEM Minimum Requirement Recommended Specification
CPU Intel Core i3 3Ghz Intel Core i7
Main Memory 2GB 4GB
Operating System
*
Windows XP Windows 7 (64bit)
Web Browser Internet Explorer 8, 9 Internet Explorer 8, 9
Graphic Card Video RAM 256MB
Resolution 1920x1080
Video RAM 1GB
Higher than 1920x1080
Network 10 Base-T Ethernet 100 Base-T Ethernet
* Operating Systems supported: Windows XP / Vista / 7

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
4.2. Quick Installation Guide
4.2.1. Connect PC and O5B3M
to network.
1.
Prepare a PC to run programs for the installation and video connection
(PC is needed to assign IP address to
2.
In the case of using PoE, connect the PC and
your LAN Switch does not support standard PoE, connect
The DC power
is applied through DC adapter.
Figure 4
4.2.2. Set IP parameters on O5B3M
Follow the sequence below for setting the IP parameter
i) Run ONSIP installer
ii) Click
(1) in ONSIP installer window.> Double click on (2) > Fill in (4) > make a selection in (5) > Fill
the parameters in (6)
iii) Click on
(9) to apply the settings.
iv)
You can connect to admin page by clicking on (10).
to network.
Prepare a PC to run programs for the installation and video connection
(PC is needed to assign IP address to
O5B3M)
In the case of using PoE, connect the PC and
O5B3M
to the network using one of the following ways. If
your LAN Switch does not support standard PoE, connect
O5B3M as sh
own in dotted line in Figure
is applied through DC adapter.
Figure 4
-1. Power and network connection
Follow the sequence below for setting the IP parameter
(1) in ONSIP installer window.> Double click on (2) > Fill in (4) > make a selection in (5) > Fill
(9) to apply the settings.
You can connect to admin page by clicking on (10).
LAN switch with
standard POE
(802.3af)
LAN switch
DC adaptor
to the network using one of the following ways. If
own in dotted line in Figure
.
(1) in ONSIP installer window.> Double click on (2) > Fill in (4) > make a selection in (5) > Fill

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Click on the field in (3)
for sorting and rearranging the list.
Select network mode that best suits from the drop down list in
ADSL and Auto (DHCP), respectively. If ADSL and Auto
deactivated.
In case of ADSL, fill the User Name and Password in (8) with the values provided by your ISP.
If DDNS service is needed,
(7).
4.2.3. Remote video connection to
O5B3M
1. Connection through Web Viewer
Web Viewer offers simplest way of video connection to
address of O5B3M
in the URL window of Internet Explorer as:
2
4
7
[e.g.] Port 80
for sorting and rearranging the list.
Select network mode that best suits from the drop down list in
(5)
. You can choose either Static or
ADSL and Auto (DHCP), respectively. If ADSL and Auto
are selected, the fields in (6)
In case of ADSL, fill the User Name and Password in (8) with the values provided by your ISP.
If DDNS service is needed,
check the box and fill the empty field with the
hostname you want in
O5B3M
Web Viewer offers simplest way of video connection to
O5B3M
. For video connection, enter the IP
in the URL window of Internet Explorer as:
3
Default port 80 can be omitted
. You can choose either Static or
are selected, the fields in (6)
are
In case of ADSL, fill the User Name and Password in (8) with the values provided by your ISP.
hostname you want in
. For video connection, enter the IP
1
6
9
5
8
10
Default port 80 can be omitted

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Default ID and password of Admin Page are
For more detailed information, please refer to the
Connection to Admin Page
[e.g.] Port 8080
Figure 4-3. Web Viewer
Default ID and password of Admin Page are
“admin”, “1234”.
For more detailed information, please refer to the
“Configuration Guide”.
Connection to Admin Page
Basic Control

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Rev.1.0 (Dec. 2015) 18
4.2.4. Additional settings through connection to the Admin Page
All parameters of the camera are factory default out of the box. For a more sophisticated target application,
parameters need to be changed through the admin page. The admin page can be connected through
“http://IP_Address:Port_Number/admin.htm”
ID and password of the administrator are required. Default ID and password are “admin”, “1234”.
It is highly recommended to change the ID and password to prevent illegal access to the IP camera.
For more detailed information, Please refer to the “Configuration Guide”.

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Rev.1.0 (Dec. 2015) 19
5. Troubleshooting
5.1. No power is applied
In case of Standard PoE (Power over Ethernet)
Power supply through standard PoE is possible only when the following conditions are met.
1. Standard PoE is supported on the product.
2. The LAN switch supports standard PoE.
Make sure that both the IP camera and the LAN switch support standard PoE (IEEE 802.3af)
In case of DC adapter
If PoE is not applied, the power and network connection should be made through separate cables.
It is recommended to use DC adapter supplied by provider for the feeding of the power. In case of
replacing the DC power supply, make sure that the power supply meets with the power
requirement of the IP camera to prevent damage or malfunction.

O
O5
5B
B3
3M
M
U
Us
se
er
r’
’s
s
G
Gu
ui
id
de
e
Rev.1.0 (Dec. 2015) 20
5.2. Cannot connect to the Video
Check the status of the network connection through PING test.
Try the following on your PC :
-
Start > Run > Cmd > Ping IP address (Ex : Ping 172.16.42.51)
-
If “Reply from ~” message is returned (
①
①①
①
in the figure below), the network connection is in normal
state. Try connection to the video again. If the problem persists, or refer to other trouble shooting notes.
-
If “Request timed out” message is returned. (
②
②②
②
in the figure below), the network connection or network
setting is not in normal state. Check the network cable and settings.
1
2
Table of contents
Other Speco IP Camera manuals

Speco
Speco O2D10 User manual

Speco
Speco O2VLB2 User manual

Speco
Speco O4P30X2 User manual

Speco
Speco O2MD1 User manual

Speco
Speco HTD8TG User manual

Speco
Speco O2D60M User manual

Speco
Speco O3FDP9 User manual

Speco
Speco Intensifier O2iTC23 User manual

Speco
Speco & IP-WDRB1 User manual

Speco
Speco O2iB8M User manual