Installation
Check that the mounting surface is flat and suitable for
the installation of this fitting.
Step 1 Attach LED channel using mounting tabs.
Mounting tabs should be spaced evenly along
the channel using approximately two per
meter.
Step 2 Connect mains supply to the PSU, connect
dimmer (If required) and make E.L.V
connections to the fitting.
WARNING: Do not look at exposed LED lamps in
operation. Eye injury can result.
Cleaning:
Fully isolate the fitting and allow to cool.
Clean the fitting with a slightly damp lint free cloth
from a mild solution of soap and water. The fitting
must be completely dry before reconnecting power.
Incompatible or abrasive chemicals can damage the
fitting, contact MSL for advice if required.
Electrical Supply
Installation must be carried out by a qualified electrician in
accordance with BS 7671:2008 Wiring Regulations.
230/240V AC 50/60Hz mains supply to a suitable 24V
SELV PSU.
Site conditions: LED equipment is more susceptible to
static damage and overvoltage than previous technology.
Before handling or connecting to the mains supply ensure
that all MSL products are protected from static discharge
and that the mains supply is to regulation. (230V +10
-6%)
Mains cables must be double insulated, strain relieved
and separated from E.L.V output cables.
This unit requires a 24V constant voltage PSU.
Observe polarity:
Positive (+) is marked as RED.
Incorrect supply or reverse polarity can cause irreparable
damage.
All connections must be made before switching on mains.
If the supply is energised prior to making the connections
to the fitting then the resulting surge will damage the LED.
Multiple LEDs should be wired in series, refer to driver
instructions for minimum/maximum load.
All lighting equipment is delicate and easily damaged
through misuse or inappropriate installation (mechanical
or electrical). Repairs and replacements may cause
delays and will be chargeable. Contact MSL for support if
required. For full warranty terms & conditions please visit
our website.
The IP rating stated is applicable only when the fitting has
been installed as per these instructions.
The light source contained in this luminaire shall only be
replaced by the manufacturer or his service agent or a
similar qualified person.
Dimming control circuit source must be of SELV insulation
class.
Ensure supply PSU and connectors are housed indoors
OR in a suitably IP rated enclosure.