Control System
General
The ventilation unit is controlled from the Premium
control panel, which is standard equipment and from
which you can also read and change settings. You can
also select three different fan speeds from the Premium
cooker hood.
Control from a Premium control panel
A Premium control panel can be installed at an optional
location, recessed in a junction box or surface mounted
on the wall. It can be located near the ventilation unit or
somewhere else, and then must be connected to the unit
via a 20 metre long modular cable. An extra control panel
can also be connected, if it is desirable to control the
ventilation unit from several places.
Selectable functions
• Application. The unit can be started and stopped.
• Fan speed. The ventilation unit fans can be set and
controlled to operate at five different speeds. The
display indicates the Away mode when the fans run
on their lowest speed and indicates the Home mode
when the fans are running at normal speed. The speed
of the supply air fan can deviate from that of the
extract air fan and the speed is controlled from the
control panel.
• Timer. The 24-hour/weekly timer has four programs.
You can set the desired times if you want the unit to
activate a desired function. The unit runs in the eco-
nomical minimum speed mode at other times (Away).
Functions: Home, Away, Boost, Cool. You can also
select the temperature of the supply air.
• Temperature. You can set the desired start tempera-
ture of the electric air heater for reheating (optional
item) within a range of 13–20 °C. You can also shut
off the reheating function.
• Negative pressure compensation. Negative pres-
sure arises in the home when a separate cooker hood
or central vacuum cleaner is used, since the extract
airflow becomes higher than the supply airflow. This
function compensates the negative pressure by auto-
matically increasing the supply airflow. A signal from
a contact in the cooker hood or the central vacuum
cleaner is required.
• Summer operation. When certain limit values are
met, the ventilation unit stops the heat exchanger
(when heat recovery isn’t needed).
• Summer night cooling. The function starts, if certain
temperature conditions are complied with. The heat
exchanger in the unit stops, the electric air heater is
switched off and control system increases the speed of
the fans. The cooler air at night, for instance, is then
utilised for cooling the home. The fan speed can be
selected.
• Cooling energy recovery. In the summer, when
the indoor air is cooler than the outdoor air, the heat
exchanger starts up.
• Fireplace switch function. The function generates
excess pressure in the home and brings about an
updraught in the chimney, which prevents smoke from
entering the room when you light a fire.
• Display of the operating speed. The operating
speed is continuously shown as text on the display
screen.
• Service reminder. The service reminder interval can
be set to a period ranging between 3–12 months.
Automatic functions
• Alarms. Indicate the need for filter change or servicing
and a possible disruption in operation.
• Heat exchanger. Starts and stops in response to sig-
nals from the temperature sensor.
• Overheating protection. For the motors and the
electric air heater.
• Freeze protection. Prevents freezing in the heat
exchanger.
The ventilation unit is controlled from the Premium control
panel.