Package Contents
• RTR505B or RTR505BL (Large Battery Type)
• Lithium Battery LS14250 (or Large Capacity Battery Kit RTR-500B1 for L type model)
• Strap (Not included with L type model)
• Manual Set (Warranty Included)
Part Names
Module Jack
LCD Display
Antenna
Optical
Communication
Area
<Side>
(L type)<Side><Front> <Back>
Wireless Data Recorder
RTR505B
User’s Manual
Thank you for purchasing our product.
To ensure safe and proper operation, please read this guide
thoroughly before use.
Overview
RTR505B is a data logger designed to measure and record
dierent items depending on the input module to be con-
nected: temperature (Thermocouple, Pt), analog signal
(4-20mA, DC voltage), and pulse.
Recorded data is then automatically collected by the Base Unit via
wireless communication and downloaded for archive and analysis.
RTR505B requires a Base Unit to carry out wireless communication.
(Compatible Base Units: RTR500BC, RTR500BW, RTR500BM, RTR-
500MBS-A, RTR-500DC, RTR-500, RTR-500NW/AW)
For the operation and conguration of the Base Unit, refer to
the instruction manual attached to the Base Unit or the RTR500B
Series Help available on T&D Website.
Wireless Data Recorder RTR505B is referred to as the “(data) logger”
or “device” in this manual.
tandd.com
© Copyright T&D Corporation. All rights reserved.
2020.11 16508210002 (1st Edition) Printed on recycled paper.
Input Modules (Sold Separately)
Measurement Item
Input Module LCD Displayed Items
Temperature
(Type K, J, T, S)
Thermocouple Module
(TCM-3010)
Measurement, Unit of Measurement,
Sensor Type, Operational Status
Temperature
(Pt100, Pt1000)
PT Module
(PTM-3010)
Measurement, Unit of Measurement,
Sensor Type, Operational Status
Voltage Voltage Module
(VIM-3010)
Measurement, Unit of Measurement,
Operational Status
4-20mA 4-20mA Module
(AIM-3010)
Measurement, Unit of Measurement,
Operational Status
Pulse Pulse Input Cable
(PIC-3150)
Measurement, Unit of Measurement,
Operational Status
• Before using the pulse input cable, it is necessary to set the measurement item to “pulse
type” in the Remote Unit Settings of the application.
• In order to change the measurement item, initialize the Remote Unit without connecting
the input module and then redo the Remote Unit registration and settings.
Make sure that the module is completely
inserted until you hear a “click” sound.
Battery Installation
Recording starts automatically by inserting the battery with the
default or previous settings.
Battery
Cover
Rubber
Packing
Screw
Lithium Battery
Default Settings
Recording Mode Endless
Recording Interval 10 minutes
Recording Start
Method
Immediate Start
• Make sure to use the proper type and
size screwdriver. (Phillips head #1
screwdriver is recommended.)
• Insert the supplied battery with the
tube attached. When using a CR2 lithi-
um battery, the tube is not necessary.
• Before closing the cover, check the
rubber packing for dust or scratches,
as they can reduce the water resis-
tance of the rubber.
• Be sure to completely close the cover.
Make sure not to over tighten the
screws.
• Appropriate Tightening Torque:
20N·cm to 30N·cm (2Kgf·cm to 3Kgf·cm)
Battery Replacement
When it is time for the battery to be
replaced, a battery warning mark will
appear. Please change the battery as
soon as possible if this mark appears.
If you continue to use the logger without changing the battery, the
current temperature and [bAtt] will be displayed alternately and
wireless communication will stop. (Recording will continue.)
Alternating
Display
• If the battery is further left unchanged, the display will automatically shut
o and all previously recorded data will be lost.
• Although the logger continues to work for a period after the battery has
been removed, leaving the device without a battery until the LCD display
goes blank will cause all recorded data to be lost.
Remote Unit Registration and Settings
Via Software and Optical Communication
Connect the Base Unit to a PC with a USB cable, and place the data
logger face down to align the communication areas as shown below.
RTR500BW,
RTR-500NW/AW
RTR500BM,
RTR-500MBS-A
RTR500BC,
RTR-500
RTR-500DC
Via Mobile App and Bluetooth®Communication
When the Base Unit is a RTR500BW, it is possible to make Base
Unit and Remote Unit settings from nearby mobile devices using
Bluetooth.
Basic Measurement Display
Display varies depending upon the input module connected.
Temperature (Thermocouple / Pt100 / Pt1000)
Temperature measurement (Unit: °F / °C) will be
displayed. Sensor type will be displayed under the
measurement; the factory default setting is Type K
and Pt (Pt100). The sensor type setting can be
changed in the Remote Unit Settings of the
application.
Voltage
Voltage measurement (Unit: V / mV) will be displayed.
Due to the wide measurement range, the device has
been set by default to adjust the decimal point
automatically to display the measurement in V. The
unit of display can be changed in the Remote Unit
Settings of the application.
4-20mA
4-20mA measurement (Unit: mA) will be displayed.
Pulse
There are two display methods for the pulse measurement. The display
method can be changed in the Remote Unit Settings of the application.
Pulse Rate (Max: 61439)
The most recent pulse count (Unit: P) for the recording
interval period will be displayed. The display will be
refreshed every one-sixtieth of the recording interval
(at minimum of every one second). 50,500 pulse count
will be displayed as [50.50P] with “K“below the
measurement value. The display is in units of 10 pulses.
Total Pulse Count
The cumulative number of pulses (Unit: P) will be
displayed from 0 to 9999. The displayed count will be
refreshed every one second, and upon exceeding
9999, the count will start over again from 0.
How to Read the LCD Display
[REC] Mark Shows the recording status.
ON: Recording in progress
BLINKING: Waiting for programmed start
OFF: Recording stopped
[ONETIME] Mark Shows the recording mode.
ON: One Time
OFF: Endless
Battery Warning
Mark Indicates it is time for the battery to be replaced.
Measurement and
Message Area
Measurements or operational messages are shown
here.
Sensor Type
The type of sensor connected to or set in the logger is
shown here.
Thermocouple: Type K, J, T, S
Platinum Thermal Resistance Sensor: Pt (Pt100), PtK
(Pt1000)
[Ir] Mark
Indicates that the logger (Remote Unit) has not been
registered to the Base Unit or the wireless communi-
cation is stopped (inactive radio).
[COM] Mark
Indicates that the device is in Bluetooth communication.
Unit of Measure-
ment Shows the unit of measurement.
• When being used in very hot or cold environments the display may become dicult to
read. This is not a malfunction.
Specications
Measurement Item Temperature, Voltage, 4-20mA, or Pulse Count (*1)
Logging Capacity
16,000 readings
Recording Interval 1, 2, 5, 10, 15, 20, 30 sec. 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode
(*2) Endless (Overwrite oldest data when capacity is full) or One Time
(Stop recording when capacity is full)
Communication
Interfaces
Short Range Wireless Communication
Frequency Range: 869.7 to 870 MHz
RF Power: 5 mW
Transmission Range: Approx. 150 meters (500 ft) if direct and
unobstructed
Bluetooth 4.2 (Bluetooth Low Energy) (*3)
Optical Communication
Power
Lithium Battery LS14250 x 1
L Type: Large Capacity Battery Adaptor Kit (RTR-500B1) (*4)
External Power Adaptor Kit RTR-500A2
Battery Life (*5) Approx. 10 months / L Type: About 4 year
Dimensions
H 62 mm x W 47 mm x D 19 mm
L Type: H 62 mm x W 47 mm x D 46.5 mm
(excluding protrusions and Input Module)
Antenna length: 24 mm
Weight Approx. 50 g / L Type: Approx. 65 g
Operating Environment
-40 to 80℃
-30 to 80℃ during wireless communication
Waterproof Capacity
IP64: Splash proof (rated for use in daily life) (*6)
Compatible Base
Units
RTR500BC, RTR500BW, RTR500BM
RTR-500DC, RTR-500MBS-A, RTR-500NW/AW (*7)(*8)
RTR-500 (*8)
*1: Measurement item depends on the input module (sold separately).
*2: Only “Endless” is available when using the RTR500BW, RTR500BM, RTR-500NW/AW or
RTR-500MBS-A
as a Base Unit.
*3: Bluetooth is available when using the RTR500BW as a Base Unit and making device
settings in the mobile app (T&D 500B Utility).
*4: When using RTR-500B1 it is necessary to purchase Lithium Battery (LS26500). For
details, contact your local authorized distributor.
*5: Battery life depends on several factors, including ambient temperature, radio
environment, frequency of communication, recording interval, and quality of the
battery being used. All estimates are based on operations carried out with a new
battery and are in no way a guarantee of actual battery life.
*6: Input module (sold separately) is not water resistant.
*7: A rmware update is required to a RTR500B series compatible version.
*8: A software update is required to a RTR500B series compatible version.
The specications listed above are subject to change without notice.
Other Indications on Display
Logging Capacity FULL
When Recording Mode has been set to “One Time” and
the logger reaches its logging capacity of 16,000 readings,
recording will automatically stop and in the LCD the
measurement and the word [FULL] will alternately appear.
Estimation of time until [FULL] is displayed
Rec Interval 1 second 30 seconds 1 minute 10 minutes 60 minutes
Time Period About 4
hours About 5 days About 11
days
About 111
days
About 1 year and
10 months
Data Transmission via Wireless Communication
The measurement and the word [SEnd] will alternately
appear when data is being sent via wireless communica-
tion to the Base Unit. Recording will continue during
wireless transmission.
Input Module Unrecognized (factory default)
This will appear if, after purchasing, the input module has
never been connected to the logger. (No unit displayed)
Input Module Unconnected or Damaged
This will appear if the device cannot conrm a connection
with the input module after having recognized it. (Unit of
Measurement displayed)
• If nothing is displayed after reconnecting the module to the device, there is a possibility
that the module or the device has been damaged.
Sensor Unconnected or Damaged
This will be displayed when a sensor has not been
connected to the module or the wire has been broken.
Recording is in progress and so is battery consumption.
• If nothing appears on display after reconnecting the sensor to the device, there is a
possibility that the sensor or the device has been damaged.
Measurement Range Exceeded
[OL] will appear if a measurement exceeds the measure-
ment range.
Display Range Exceeded
When measuring voltage in mV range, the measurement
in the LCD display will ash if it exceeds the display range
of the device.

Other T&D Data Logger manuals

T&D TR4A Series User manual

T&D

T&D TR4A Series User manual

T&D RTR-57U User manual

T&D

T&D RTR-57U User manual

T&D TR-57DCi User manual

T&D

T&D TR-57DCi User manual

T&D RTR-505 User manual

T&D

T&D RTR-505 User manual

T&D RTR500BW User manual

T&D

T&D RTR500BW User manual

T&D RTR-500DC User manual

T&D

T&D RTR-500DC User manual

T&D TR-7wf Series Instruction sheet

T&D

T&D TR-7wf Series Instruction sheet

T&D RTR-501 User manual

T&D

T&D RTR-501 User manual

T&D RTR-53A User manual

T&D

T&D RTR-53A User manual

T&D TR-7wf Series Guide

T&D

T&D TR-7wf Series Guide

T&D RTR-505 User manual

T&D

T&D RTR-505 User manual

T&D RTR505B User manual

T&D

T&D RTR505B User manual

T&D MCR-4V User manual

T&D

T&D MCR-4V User manual

T&D TR41 User manual

T&D

T&D TR41 User manual

T&D TR71A User manual

T&D

T&D TR71A User manual

T&D RTR-53 User manual

T&D

T&D RTR-53 User manual

T&D TR-71W User manual

T&D

T&D TR-71W User manual

T&D RTR505B User manual

T&D

T&D RTR505B User manual

T&D TR-7wf Series Instruction sheet

T&D

T&D TR-7wf Series Instruction sheet

T&D RTR-601 Series User manual

T&D

T&D RTR-601 Series User manual

T&D TR-71U User manual

T&D

T&D TR-71U User manual

T&D RTR-61 User manual

T&D

T&D RTR-61 User manual

T&D TR41 User manual

T&D

T&D TR41 User manual

T&D RTR-505 User manual

T&D

T&D RTR-505 User manual

Popular Data Logger manuals by other brands

Calypso Instruments ULTRASONIC Portable Solar user manual

Calypso Instruments

Calypso Instruments ULTRASONIC Portable Solar user manual

Gemini Tinytag TE-4904 manual

Gemini

Gemini Tinytag TE-4904 manual

MadgeTech CurrentX Series Product user guide

MadgeTech

MadgeTech CurrentX Series Product user guide

EO SwimBETTER90 operating instructions

EO

EO SwimBETTER90 operating instructions

AKO AKO-15740 user manual

AKO

AKO AKO-15740 user manual

Racelogic VBOX Sport Getting started

Racelogic

Racelogic VBOX Sport Getting started

Inductosense WAND user manual

Inductosense

Inductosense WAND user manual

AST ADL 280 RFID operating manual

AST

AST ADL 280 RFID operating manual

LogTag Recorders UTRID-16 Product user guide

LogTag Recorders

LogTag Recorders UTRID-16 Product user guide

SENSECAP S2100 user guide

SENSECAP

SENSECAP S2100 user guide

JRI Mini SPYRF Green user manual

JRI

JRI Mini SPYRF Green user manual

Endress+Hauser Tankvision Multi Scan NXA83B operating instructions

Endress+Hauser

Endress+Hauser Tankvision Multi Scan NXA83B operating instructions

MadgeTech VFC2000-MT Product user guide

MadgeTech

MadgeTech VFC2000-MT Product user guide

Stoneridge Veeder-Root 2400 Series user manual

Stoneridge

Stoneridge Veeder-Root 2400 Series user manual

National Instruments NI 781 R Series user manual

National Instruments

National Instruments NI 781 R Series user manual

SENSECAP S2100 user guide

SENSECAP

SENSECAP S2100 user guide

SMTEN ShineWiFi Quick Installation Guideline

SMTEN

SMTEN ShineWiFi Quick Installation Guideline

SK SATO SK-L754 instruction manual

SK SATO

SK SATO SK-L754 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.