manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. T&D
  6. •
  7. Data Logger
  8. •
  9. T&D RTR-501 User manual

T&D RTR-501 User manual

4
RTR-501 / 501L:
Temperature
RTR-502 / 502L:
Temperature
RTR-503 / 503L:
Temperature and Humidity
The RTR-501 with internal
sensor provides optimum
waterproof and dustproof
capabilities. This is the
perfect Data Logger for use
in harsh environments:
whether that may be indoor
frozen or refrigerated
storage or high humidity,
high dust outdoor
applications.
Measurement Range
-
40 to 80 °C
Water Resistance
Immersion proof
Not submersible
We offer a variety of
optional sensors to meet
your needs; from ones
with stainless protection
to those that can be
used in water. For details
see the Optional
Sensors page.
Measurement Range
-
60 to 155 °C
Water Resistance
Splash proof (rated for use
in daily life when the sensor
is connected. Not for
continued immersion.
The RTR-503 uses a
sensor that measures
and records both
temperature and
humidity.
Measurement Range
Temperature : 0 to 55 °C
Humidity: 10 to 95%RH
Water Resistance
Splash proof (rated for use in
daily life when the sensor is
connected. Not for continued
immersion.
Temperature Sensor
Internal Temperature Sensor
Temperature Sensor : TR-5106 (Included)
Water proof
Thermistor Area
Water Resistance:
The uoropolymer-coated section is waterproof. Other
sections are immersion proof
Temperature / Humidity Sensor : TR-3310
(Included)
Temp/Humidity Sensor Area
Water Resistance: None
RTR-505: For Measuring Signals from Multiple Types of Sensors and Instruments
RTR-505-TC / RTR-505-TCL:
Thermocouple
RTR-505-Pt / RTR-505-PtL:
Pt
RTR-505-V / RTR-505-VL:
Voltage
RTR-505-TC is a type of
Data Logger supplied with
the Input Module which
supports the following types
of thermocouple sensors: K,
J, T, and S. It is possible to
measure and record
temperature in a range of
-199 to 1700˚C.
Measurement Range
K:
-
199 to 1300 ˚C
J:
-
199 to 750 ˚C
T:
-
199 to 400 ˚C
S:
-
20 to 1700 ˚C
RTR-505-Pt is a Data
Logger which supports
Pt100 (3-wire) and
Pt1000 (3-wire) sensors.
Measurement Range
-
199 to 600 ˚C
RTR-505-V is a Data
Logger designed to
measure and record voltage
signals from various types
of sensors and measuring
devices. Two types of
recording method
(instantaneous or average)
are available to be chosen
from. It is equipped with a
preheat function that
transmits a preheat signal
synchronized with the
recording interval to turn
sensors or other devices
ON and OFF.
Measurement Range
0 to 22 V
Note: Currently, this product is not compatible with
RTR
-
500GSM
Input Module : TCM-3010 (Included) Input Module : PTM-3010 (Included) Input Module : VIM-3010 (Included)
Wireless Data Loggers
RTR-501/502/503: Data Loggers Built to Work and Last in Harsh Environments
13
For RTR-501 / 502 / 503 / 505
Large Capacity Battery Kit
Attachment hook
Maintenance Set
(TR-00P1)
[Unit:mm]
24
14
4
3
31
62
47
RTR-500B1
Power: Lithium Battery x 1 (LS26500) (*1)
Battery Life: about 4 years (*2)
Waterproof Capability: Splash proof
Operating Temperature:
-
40 to 80˚C (*3)
Weight: about 75g (including Lithium Battery)
Kit Contents:
Large Capacity Battery Adaptor
Attachment hook
and Maintenance Set (TR
-
00P1)
Install by taking off the back
cover and removing the
battery.
*1: When using RTR
-
500B1 it is necessary to purchase Lithium Battery (LS26500). For details,
contact your local authorized distributor.
*2: Battery Life varies depending on measuring environment, recording interval, transmission
frequency, and ambient temperature. The battery life estimated here is calculated using a
new battery under normal operating conditions and in no way should be understood as a
guarantee of battery life.
*3: Operating temperature depends on the specications for the data logger being used.
RTR-500 Series - Options
Input Modules for RTR-505 / 505L
Materials: Polycarbonate Vinyl Coated Electrical Wire M3.5 Crimp Terminal
Note: Input Module is not water resistant.
Thermocouple Module (RTR-505-TC / 505-TCL) Pt Module (RTR-505-Pt / 505-PtL)
TCM-3010
Compatible Sensors:
Thermocouple: Type K, J, T, S
Sensor Connection:
Miniature Thermocouple Connector
14.5
27
54.5 78
[Unit: mm ]
PTM-3010
Compatible Sensors:
Pt100 (3-wire), Pt1000 (3-wire)
Sensor Connection:
Screw Clamp Terminal Block: 3-Terminal
[Unit: mm ]
14.5 47.8 78
27
Operating Environment:
Temperature:
-
40 to 80 °C
Humidity: 90 %RH or less (no condensation)
Operating Environment:
Temperature:
-
40 to 80 °C
Humidity: 90 %RH or less (no condensation)
4-20mA Module (RTR-505-mA / 505-mAL) Pulse Input Cable (RTR-505-P / 505-PL)
AIM-3010
Measurement Range:
0 to 20mA (Operational up to 40 mA)
Accuracy:
± (0.05 mA + 0.3 % of reading) (for
Input Module operating environment
of 10 to 40 °C)
19.4 46 78
[Unit: mm ]
27
PIC-3150
100 1400
[Unit: mm ]
Operating Environment:
Temperature:
-
40 to 80 °C
Humidity: 90%RH or less (no condensation)
Voltage Module (RTR-505-V / 505-VL) Input Module Extension Cable
VIM-3010
Measurement Range: 0 to 22 V
Accuracy:
± (0.5 mV + 0.3 % of reading) (for
Input Module operating environment
of 10 to 40 °C)
[Unit: mm ]
19.4 46 78
27
TR-3C30
[Unit: mm ]
41
3000
26
1.9
Measurement Resolution: Minimum of 0.1mV
Preheat Function: 3V to 20V100mA
Operating Environment:
Temperature:
-
40 to 80 °C
Humidity: 90 %RH or less (no condensation)
Waterproof Capacity: Splash proof (rated for use in daily life)
Temperature Durability:
-
25 to 60 °C
Note: Only one extension cable per input module.
Pt100 Sensor
For details about Pt100 Sensor, please visit the T&D Website.
Note: Pt100 Sensor is produced only upon receipt of order.
Wall Attachments
TR-05K3
Material: Polycarbonate
Contents:
Lock Screw x 2
Double-sided Adhesive tape
Dimensions :
W 66.6 x H 70 x D 24.7mm
Screw Holes: 2 - ø 4.2
TR-05K3L (for L type)
Material: Polycarbonate
Contents:
Lock Screw x 2
Double-sided Adhesive tape
Dimensions :
W 66.6 x H 70 x D 51.7 mm
Screw Holes: 2 -ø 4.2
Note: Cracks may develop if exposed to strong impact at temperatures of
-
30 °C or less.
16
RTR-500 Series - Specications
Remote Unit
Product RTR
-
505-TC/
505-TCL
RTR
-
505-Pt/
505-PtL
RTR
-
505-V /
505-VL
RTR
-
505-mA/
505-mAL
RTR
-
505-P/
505-PL
Measurement Channels Temperature 1ch Temperature 1ch Voltage 1ch 4
-
20mA 1ch Pulse 1ch
Sensor Thermocouple:
Type K, J, T, S
Pt100, Pt1000
(3-wire) - - -
Measurement Units °C, °F °C, °F V, mV mA P
Measurement Range
-
199 to 1700 °C
-
199 to 600 °C 0 to 22 V 0 to 20 mA
(Operational up to 40 mA)
Input Signal:
Non-voltage Contact Input
Voltage Input (0 to 27 V)
Detection Voltage:
Lo: 0.5 V or less
Hi: 2.5 V or less
Input Impedance:
Approx.100 KΩpull up
Chattering Filter:
ON: 15 Hz or less
OFF: 3.5 kHz or less
Maximum Count:
61,439/Recording Interval
Accuracy
Thermocouple Measurement
±0.3 °C + 0.3 % of reading
(Type K, J, T)
±1°C + 0.3 % of reading
(Type S)
Cold Junction Compensation
±0.3 °C (10 to 40 °C)
±0.5 °C (
-
40 to 10 °C / 40 to
80 °C)
±0.3 °C + 0.3 % of reading
(10 to 40 °C)
±0.5°C + 0.3 % of reading
(
-
40 to 10 °C / 40 to 80 °C)
±0.5 mV + 0.3 % of reading
(10 to 40 °C)
±1 mV + 0.5 % of reading
(
-
40 to 10 °C / 40 to 80 °C)
±0.05 mA + 0.3 % of reading
(10 to 40 °C)
±0.1mA + 0.3 % of reading
(
-
40 to 10 °C / 40 to 80 °C)
Note: The above mentioned temperature is the operating environment for Input Module only.
Measurement Resolution Type K, J, T : 0.1 °C
Type S: approx. 0.2 °C 0.1 °C
Up to 400 mV : 0.1 mV,
Up to 800 mV : 0.2 mV,
Up to 999 mV : 0.4 mV,
Up to 3.2 V : 1 mV,
Up to 6.5 V : 2 mV,
Up to 9.999 V : 4 mV,
Up to 22 V : 10 mV
0.01 mA
Logging Capacity 16,000 readings
Recording Interval Select from 15 choices: 1, 2, 5, 10, 15, 20, 30 sec. or 1, 2, 5, 10, 15, 20, 30, 60 min.
Recording Mode (*1) Endless (Overwrite oldest data when capacity is full) or One Time (Stop recording when capacity is full)
LCD Display Items Measurements, Battery Life Warning, etc.
Communication Interfaces
Wireless Communication (Short Range Radio Communication)
FCC Part15 Section247 / IC RSS
-
210 (Frequency Range: 902 to 928 MHz, RF Power: 7 mW)
ETSI EN 300 220 (Frequency Range: 869.7 to 870MHz, RF Power: 5 mW)
Optical Communication (proprietary protocol)
Wireless Transmission
Range Approx. 150 meters (500 ft) if direct and unobstructed
Power Lithium Battery: LS14250 (*2) or CR2 (*3) x 1 L Type: Large Capacity Battery Adaptor Kit (RTR
-
500B1) (*4)
External Power Adaptor Kit (RTR
-
500A1: sold separately)
Battery Life (*5)About 10 months
L Type: About 4 years
Dimensions
H 62 mm x W 47 mm x D 19 mm
L type: H 62 mm x W 47 mm x D 46.5 mm
(excluding protrusions and Input Module)
Antenna length: 24 mm
Weight
Approx. 56 g
L Type: approx. 109 g
(including battery / excluding Input Module)
Operating Environment
-
30 to 80 °C
(The environmental operating range of the logger unit is
-
40 to 80 °C, but wireless communications cannot be utilized in an environment less than
-
30 °C.)
Waterproof Capacity (*6) IP64: Splash proof (rated for use in daily life) Note: Input Module is not water resistant.
Accessories
Input Module
(TCM
-
3010)
Input Module
(PTM
-
3010)
Input Module
(VIM
-
3010)
Input Module
(AIM
-
3010)
Input Module
(PIC
-
3150)
Tubed Lithium Battery (LS14250) or Large Capacity Battery Adaptor Kit (RTR
-
500B1), Strap, User's Manual (Warranty Included)
Compatible Base Units RTR
-
500, RTR
-
500NW/500AW, RTR
-
500DC, RTR
-
500GSM RTR
-
500, RTR
-
500NW/500AW, RTR
-
500DC
*1: Only "Endless" is available when using RTR
-
500W for Windows or RTR
-
500GSM for Windows.
*2: The included lithium battery (LS14250) is not sold in stores. Please purchase the optional battery set for low-temperature use (TR
-
11P2) for replacement.
*3: Only use the CR2 within temperature range of - 20 to 60°C, avoiding exposing the CR2 to excessive vibration such as transportation.
*4: When using RTR
-
500B1 it is necessary to purchase Lithium Battery (LS26500). For details, contact your local authorized distributor.
*5: Battery life varies depending upon the ambient temperature in which it is used, the recording interval, the frequency of communication, and the battery performance. All estimates are based on
operations carried out with a new battery and are in no way a guarantee of actual battery life.
*6: This is the waterproof capacity of the data logger with the Input Module connected.
The specications listed above are subject to change without notice.
Connect
Colors in the photos in this catalog may be different from real product colors. The specifications and designs of the products in this catalog are true as of March 2012.
Specifications are subject to change without notice. Microsoft® and Windows® are registered trademarks of Microsoft Corporation USA and other countries. GSM is a
trademark of GSM MOU Association. All registered trademarks, company names, product names and logos mentioned herein are the property of T&D Corporation or of
their respective owners.
T&D Corporation
817-1 Shimadachi, Matsumoto, Nagano Japan 390-0852
Please send your inquiries to:
E-mail : [email protected]
Facsimile : (+81) 263-40-3152
Distributor
2012. 03. 16304590008D
T&D Website
For product information, software update and FAQ ;
http://www.tandd.com/ Caution regarding safety
For safe operation carefully read instructions before using the product.
System Setup
Remote Unit
RTR-501 / 502 / 503
(Sensor Included)
RTR-505
(Input Module or
Input Cable Included)
RTR-574
(Sensor Included)
Lithium Battery
inserted into a tube
(LS14250 (SAFT)
Included
RTR-500A1
External Power
Adaptor Kit
Sold Separately
RTR-500B1 *
Large Capacity
Battery Adaptor Kit
Sold Separately
* When using RTR
-
500B1 it is necessary
to purchase Lithium Battery (LS26500).
Base Unit
RTR-500GSM
or
or
AA Alkaline
Battery x 4
Included
External Power Cable
BC
-
0201
Included
Power
Power
Power
USB Cable (US-15C)
USB Cable (US-15C)
USB Cable (US-15C)
USB Cable (US-15C)
LAN Cable for 500AW (LN-20W)
Software
Software
Install
Install
Install
Install
Install
Connect
Connect
Connect
Connect
Base Unit / Repeater
RTR-500
Base Unit
RTR-500NW
RTR-500AW
Base Unit
RTR-500DC
AA Alkaline Battery x1
Included
Some devices such as a hub, wireless
LAN access point, server, and so on are
sold separately and may be necessary
to connect to a local network. T&D does
not manufacture or sell these items.
Initial Settings
Function Settings
Initial Settings
Function Settings
Power
Power
Software
Software
* It is not possible to
simultaneously connect
more than one Base Unit to
a PC.
AA Alkaline
Battery x2
Not Included
AAA Alkaline
Battery x2
Nickel Hydride
Battery x2
Not Included
AC Adaptor
Sold Separately
AD
-
0638 or
AD
-
0638-C
AC Adaptor
Sold Separately
AD
-
0605 or AD
-
05C1
Purchase Extra Items Separately
for RTR-500GSM
We do not handle or sell these items.
SIM Card
Required item
for operation
External Output / Input
Compatible Connector
Voltage : DC 8-34V
Current : MAX 2A
External Power
Supply
GPS Reciever
Use as a Repeater
AC Adaptor
Sold Separately
AD
-
0638 or
AD
-
0638-C
AC Adaptor
Sold Separately
AD
-
0638 or
AD
-
0638-C
Power

Other manuals for RTR-501

3

This manual suits for next models

11

Other T&D Data Logger manuals

T&D TR-5xU Series User manual

T&D

T&D TR-5xU Series User manual

T&D RTR-61 User manual

T&D

T&D RTR-61 User manual

T&D RTR500BW User manual

T&D

T&D RTR500BW User manual

T&D RTR-505 User manual

T&D

T&D RTR-505 User manual

T&D RTR-71 User manual

T&D

T&D RTR-71 User manual

T&D TR41 User manual

T&D

T&D TR41 User manual

T&D TR71A User manual

T&D

T&D TR71A User manual

T&D RTR505B User manual

T&D

T&D RTR505B User manual

T&D RTR505B User manual

T&D

T&D RTR505B User manual

T&D TR-7wb Series User manual

T&D

T&D TR-7wb Series User manual

T&D RTR-500DC User manual

T&D

T&D RTR-500DC User manual

T&D RTR-500DC User manual

T&D

T&D RTR-500DC User manual

T&D TR-7wf Series Instruction sheet

T&D

T&D TR-7wf Series Instruction sheet

T&D RTR-505 User manual

T&D

T&D RTR-505 User manual

T&D TR-7wb Series User manual

T&D

T&D TR-7wb Series User manual

T&D TR-77Ui User manual

T&D

T&D TR-77Ui User manual

T&D TR41 User manual

T&D

T&D TR41 User manual

T&D TR-7wf Series Instruction sheet

T&D

T&D TR-7wf Series Instruction sheet

T&D RTR-505 User manual

T&D

T&D RTR-505 User manual

T&D RTR-505 User manual

T&D

T&D RTR-505 User manual

T&D RTR502B User manual

T&D

T&D RTR502B User manual

T&D RTR-501 User manual

T&D

T&D RTR-501 User manual

T&D TR-7wf Series Guide

T&D

T&D TR-7wf Series Guide

T&D RTR-53A User manual

T&D

T&D RTR-53A User manual

Popular Data Logger manuals by other brands

Aquametro CONTOIL DFM 8ECO Mounting and operating instructions

Aquametro

Aquametro CONTOIL DFM 8ECO Mounting and operating instructions

FRO­NIUS Datalogger Web operating instructions

FRO­NIUS

FRO­NIUS Datalogger Web operating instructions

iSens makseNSE ILOGGER CASE user manual

iSens

iSens makseNSE ILOGGER CASE user manual

Intempco CX600 Series manual

Intempco

Intempco CX600 Series manual

NeuLog NUL-208 Guide

NeuLog

NeuLog NUL-208 Guide

Furuno VR-7000S installation manual

Furuno

Furuno VR-7000S installation manual

Fluke 1742 Quick reference guide

Fluke

Fluke 1742 Quick reference guide

SOMMER MRL-7 user manual

SOMMER

SOMMER MRL-7 user manual

Aim HYDRA EMS NEMESIS 2.5 Interface connections

Aim

Aim HYDRA EMS NEMESIS 2.5 Interface connections

sauermann Class 320 user manual

sauermann

sauermann Class 320 user manual

METER EM50 Series quick start guide

METER

METER EM50 Series quick start guide

Triplett SLDL20 user manual

Triplett

Triplett SLDL20 user manual

Data Harvest EASYSENSE Q Advanced manual

Data Harvest

Data Harvest EASYSENSE Q Advanced manual

LogTag UTRED30-WiFi Product user guide

LogTag

LogTag UTRED30-WiFi Product user guide

Datafox Evo 4.6 FleKey manual

Datafox

Datafox Evo 4.6 FleKey manual

SATO SK-L751-21 instruction manual

SATO

SATO SK-L751-21 instruction manual

ALAT UJI HOBO UX120-017 manual

ALAT UJI

ALAT UJI HOBO UX120-017 manual

LogTag USRID-16 quick start guide

LogTag

LogTag USRID-16 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.