INSTRUCTION MANUAL
RWS1000B•1500B Series
TDKLambda
<Page>
CAUTION on USE
• Product individual notes are shown in the instruction manual. If there is any difference with common notes
individual notes shall have priority.
• Before using this product, be sure to read the catalog and instruction manual. There is risk of electric shock or
damage to the product or fire due to improper use.
• Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within
specifications, otherwise the product will be damaged, or cause electric shock or fire.
•If the builtin fuse is blown, do not use the product even after replacing the fuse as there is risk of abnormality
inside. Be sure to request repair to our company.
•For products without builtin protection circuit (element, fuse, etc.), insert fuse at the input to prevent smoke,
fire during abnormal operation.
As for products with builtin protection circuit, depending on usage conditions, builtin protection circuit might
not work. It is recommended to provide separate proper protection circuit.
•For externally mounted fuse do not use other fuses aside from our specified and recommended fuse.
•This product was made for general purpose electronic equipment use and is not designed for applications
requiring high safety (such as extremely high reliability and safety requirements. Even though high reliability
and safety are not required, this product should not be used directly for applications that have seriuos risk for
life and physical safety. Take sufficient consideration in failesafe design (such as providing protective circuit
or protective device inside the system, providing redundant circuit to ensure no instability when single device
failure occurs).
•When used in environments with strong electromagnetic field, there is possibility of product damage due to
malfunction.
•When used in environment with corrosive gas (hydrogen sulfide, sulfur dioxide, etc.) , there is possibility that
they might penetrate the product and lead to failure.
•When used in environments where there is conductive foreign matter or dust, there is possibility of product
failure or malfunction.
•Provide countermeasure for prevention of lightning surge voltage as there is risk of damage due to abnormal
voltage.
•Connect together the frame ground terminal of the product and the ground terminal of the equipment for safety
and noise reduction. If these ground is not connected together, there is risk of electric shock.
•Parts with lifetime specifications (builtin fan, electrolytic capacitor) are required to be replaced periodically.
Set the overhaul period depending on the environment of usage and perform maintenance.
Also, note that there are cases when EOL products cannot be overhauled.
•Take care not to apply external abnormal voltage to the output. Especially, applying reverse voltage or
overvoltage more than the rated voltage to the output might cause failure, electric shock or fire.
• This product have a builtin fan for aircooling. Do not block the air intake and exhaust as this might lead to
fire.
• This product have possibility that hazardous voltage may occur in output terminal depending on failure mode.
The output of these products must be protected in the end use equipment to maintain SELV.
Special Instructions for IEC/EN/ES/CSA 606011 [For RWS1000B/ME, RWS1500B/ME]
• There products are designed for continuous operation within an overall enclosure, and must be mounted such
that access to the mains terminals is restricted.
• These products are not suitable for use in the presence of flammable anesthetics mixtures with air or with
oxygen, or with nitrous oxide.
• The output circuit has not evaluated for connecting to Applied Parts. For end products intended to connect the
output circuit to Applied Parts, suitable evaluation of the separation, leakage current, dielectric voltage
withstand, and related requirements should be conducted.
• The input circuit includes only one fuse in the Line conductor. Consideration shall be given in the enduse
product regarding addition of the second fuse having the same or better characteristics in order to comply with
fusing requirements of Clause 8.11.5 of the Standard.
• These products provide One Means Of Patient Protection (1MOPP) between Primary/Secondary and FG, and
Two Means Of Patient Protection (2MOPP) between Primary and Secondary.
2/23