Informaon requirements for electrical room heaters
Type: TT-TT-KS KS S / N/TT KS H (these devices shall be movable and may only be used with castors or feet)
Designaon Symbol Rate Unit Designaon Unit
Heang capacity Type of heat supply, only for electrical storage heaters in rooms (select one
type)
Nominal thermal
output Pnom 0.5 1.0 1.2 1.5 1.8 2.0 2.4 2.8 kW Manual thermal charge control, with an integrated thermostat NO
Minimal thermal
output (indicave) Pmin 0.5 1.0 1.2 1.5 1.8 2.0 2.4 2.8 kW Manual thermal charge control with acknowledgement of the
room inside and /or outside temperature
NO
Maximum con-
nuous thermal
performance
Pmax,c 0.5 1.0 1.2 1.5 1.8 2.0 2.4 2.8 kW
Electronic charge control with acknowledgement of the room
inside and /or outside temperature
NO
Auxiliary current
consumpon
Heang power supported with a fan NO
At nominal thermal
output elmax 0.5 1.0 1.2 1.5 1.8 2.0 2.4 2.8 kW Type of heang power / room temperature Control (select one
type)
At the minimum
heang capacity elmin <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 WSingle-stage heang capacity; no room temperature control
At the standby
mode elSB <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 <0.5 WTwo or more manual stages, no room temperature control NO
With mechanical room temperature control NO
With electronic room temperature control NO
Electronic temperature control in the room, depending on the
me of day
YES
Electronic temperature control in the room, depending on the
weekday
NO
Other control opons (mulple choice is possible) NO
Room temperature control with presence detecon
Room temperature control with detecon of an opened window NO
With remote control opon NO
With adapve start control NO
With limitaon of heang me NO
With a black lamp sensor NO
7.1 Tables
Type: TT-KS S RF / TT-KS N RF / TT-KS H RF (addional thermostat TPF-Eco and Eco interface is required)
Designaon Symbol Rate Unit Designaon Unit
Heang capacity Type of heat supply, only for electrical storage heaters in rooms (select one
type)
Nominal thermal
output Pnom 0.5 1.0 1.2 1.5 1.8 2.0 2.4 2.8 kW Manual thermal charge control, with an integrated thermostat NO
Minimal thermal
output (indicave) Pmin 0.5 1.0 1.2 1.5 1.8 2.0 2.4 2.8 kW Manual thermal charge control with acknowledgement of the
room inside and /or outside temperature
NO
Maximum con-
nuous thermal
performance
Pmax,c 0.5 1.0 1.2 1.5 1.8 2.0 2.4 2.8 kW
Electronic charge control with acknowledgement of the room
inside and /or outside temperature
NO
Auxiliary current
consumpon Heang power supported with a fan NO
At nominal thermal
output elmax 0.5 1.0 1.2 1.5 1.8 2.0 2.4 2.8 kW Type of heang power / room temperature Control (select one
type)
At the minimum
heang capacity elmin 2 2 2 2 2 20 2 2 WSingle-stage heang capacity; no room temperature control NO
At the standby
mode elSB 0.47 0.47 0.47 0.47 0.47 0.47 0.47 0.47 WTwo or more manual stages, no room temperature control NO
With mechanical room temperature control NO
With electronic room temperature control NO
Electronic temperature control in the room, depending on the
me of day
NO