TECshow reefTEC User manual

USER MANUAL
Read the user manual before turning on the product.

1
INTRODUCTION
Thank you for using our Products .This lighting has got the nice sculpt , efficient , save
electricity and durable . It is suitable for disco, stage , building etc . Direct input of DMX512
signal to unit to allow it be controlled by any DMX512 controller. Powerful internal
programs allow customers to program freely to any different lighting project requirements
for installation or shows.
This product complies with the following standards:
IEC60598-1:2003
IEC60598-2-17:1984+A2:1990
DMX512 , Master/Slave , Sound active control mode
Professionally designed pre-programmed effects
Long-life LEDs
Strobe effect 1~20 flash per sec.
4 DMX-channels
9 Dip Switches for adjusting the DMX-starting address
DMX-control via every standard DMX-controller
Ø5 LED (16R+16G+16B+16W)X2
50 000 hours LED life
Compact housing
FEATURES

2
SAFETY INSTRUCTIONS
Important!
Please read these instructions carefully , which includes important information about the
installation, usage and maintenance of this product.
Every person involved with the installation, operation and maintenance of this device has
to be qualified and follow the instructions of this manual .
Manufacturer will not with responsibility for those operation not according to this
Instruction.
-Always make sure that you are connecting to the proper voltage, and that the line
voltage you are connecting to is not higher than that stated on the decal or rear panel of
the fixture.
- Always ground (earth) the fixture electrically.
-Do not attempt to bypass the fuse, and replace the defective fuse with ones of the
specified type and rating only.
-Do not spill water or other liquids into or on to your unit.
-During long periods of non-use, disconnect the unit's main power.
-Do not attempt to operate this unit if the power cord has been frayed or broken.
-Never use the device during thunderstorms. Over voltage could destroy the device.
Always disconnect the device during thunderstorms.
-There are no user serviceable parts inside the unit. Do not open the housing or attempt
any repairs yourself.
-Maximum ambient temperature (Ta) is 35°C.
-The surface temperature of the light can reach to 50°C .
-Do not attempt to operate this unit, if it becomes damaged.
-Always be sure to mount this unit in an area that will allow proper ventilation.
-Do not directly stare at the light when it works.
-When suspending the fixture above ground level, verify that the structure can hold at
least 10 times the weight of all installed devices.
-Verify that all external covers and rigging hardware are securely fastened and use an
approved means of secondary attachment such as a safety cable.
-Verify that all screws are tightly fastened.

3
INSTALLATION
W A R N I N G !
For safe operation, the fixture must be grounded (earthed).
Power supply
Before plugging your unit in, be sure the voltage and frequency in your area must match
the required voltage for your fixture. you should be sure your unit voltages matches the
wall outlet voltage before attempting to operate your fixture.
Data Connection
The fixture provides 3-Pin XLR socket connector, Pin 1 is signal ground, Pin 2 is signal -,
Pin 3 is signal +.,data link as below:
1
3 3
2
1
2
signal+
Signal ground
signal-
DMX512 OUT
socket
DMX512 IN
socket
Connection method:
In DMX mode , Connect the DMX-output of the DMX controller to the DMX IN of the first
lighting , then connect the DMX OUT of the first lighting to the DMX IN of the second
lighting , and so on . In Master/Slave mode , it’s no need to connect controller .
If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to
3 pin adapter.The chart below details a proper cable conversion.

4
Conductor 3-Pin Female(Out) 5-Pin Male(In)
Signal Ground
Pin 1
Pin 1
Signal -
Pin 2
Pin 2
Signal + Pin 3 Pin 3
Not used Pin 4: Do not use
Not used
Pin 5: Do not use
In DMX mode , insert a termination plug in the output of the last fixture on the link could
reduce the reflection and interference. The termination plug , which is a male XLR plug
with a 120 ohm, 0.25 watt resistor soldered between pins 2 and 3.
Mounting
This fixture can be mounted on a truss using a clamp in any position or against a flat
surface . When suspending the fixture above ground level, verify that all external covers
and rigging hardware are securely fastened and use an approved means of secondary
attachment such as a safety cable .
DIP SWITCH FUNCTION
ON
OFF
function
9 1 2 3 4 5 6 7 8 10 Auto program/Master
9,10 1 2 3 4 5 6 7 8
Sound control (when sound off , it will
run automatically)/Master
10
1~9 are use for setting DMX
starting address DMX/Slave
In Master mode , set only one lighting to Master-device . and others to Slave-device , then
all lightings run follow master-device synchronously .
In DMX mode , the fixture may be operated with a controller in DMX control mode . Dip 1
to Dip 9 are used for setting the starting address .

5
Set starting address
This DMX mode enables the use of a universal DMX controller device. Each fixture requires
a "start address" from 1 to 512. A fixture requiring one or more channels for control begins
to read the data on the channel indicated by the start address. For example, a fixture that
uses 3 DMX channels and was addressed to start on DMX channel 100, would read data
from channels: 100, 101, 102. Choose start addresses so that the channels used do not
overlap, and note the start address selected for future reference.
Set the start address using the group of DIP switches located back of the fixture. Each dip
switch has an associated value. Adding the value of each switch in the ON position will
provide the start address. Figuring out which switches to toggle ON given a specific start
address can be accomplished by determining which switch values will add up to the address
value and turning these switches on.
Dip 1 2 3 4 5 6 7 8 9
value 1 2 4 8 16 32 64 128 256
For example: Set DMX address 203
203=128+64+8+2+1
so Dip 1,Dip 2,Dip 4 ,Dip 7,Dip 8 should be dialed to ON
Refer to DMX Address Quick Reference Chart on the next page , you should set the address
dip switch more easily and quickly.

6
DMX ADDRESS QUICK REFERENCE CHART
0=OFF
1=ON
X=OFF or ON
#9
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
#8
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
#7
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
#6
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
#1
#2
#3
#4
#5
0
0
0
0
0
32
64
96
128
160
192
224
256
288
320
352
384
416
448
480
1
0
0
0
0
1
33
65
97
129
161
193
225
257
289
321
353
385
417
449
481
0
1
0
0
0
2
34
66
98
130
162
194
226
258
290
322
354
386
418
450
482
1
1
0
0
0
3
35
67
99
131
163
195
227
259
291
323
355
387
419
451
483
0
0
1
0
0
4
36
68
100
132
164
196
228
260
292
324
356
388
420
452
484
1
0
1
0
0
5
37
69
101
133
165
197
229
261
293
325
357
389
421
453
485
0
1
1
0
0
6
38
70
102
134
166
198
230
262
294
326
358
390
422
454
486
1
1
1
0
0
7
39
71
103
135
167
199
231
263
295
327
359
391
423
455
487
0
0
0
1
0
8
40
72
104
136
168
200
232
264
296
328
360
392
424
456
488
1
0
0
1
0
9
41
73
105
137
169
201
233
265
297
329
361
393
425
457
489
0
1
0
1
0
10
42
74
106
138
170
202
234
266
298
330
362
394
426
458
490
1
1
0
1
0
11
43
75
107
139
171
203
235
267
299
331
363
395
427
459
491
0
0
1
1
0
12
44
76
108
140
172
204
236
268
300
332
364
396
428
460
492
1
0
1
1
0
13
45
77
109
141
173
205
237
269
301
333
365
397
429
461
493
0
1
1
1
0
14
46
78
110
142
174
206
238
270
302
334
366
398
430
462
494
1
1
1
1
0
15
47
79
111
143
175
207
239
271
303
335
367
399
431
463
495
0
0
0
0
1
16
48
80
112
144
176
208
240
272
304
336
368
400
432
464
496
1
0
0
0
1
17
49
81
113
145
177
209
241
273
305
337
369
401
433
465
497
0
1
0
0
1
18
50
82
114
146
178
210
242
274
306
338
370
402
434
466
498
1
1
0
0
1
19
51
83
115
147
179
211
243
275
307
339
371
403
435
467
499
0
0
1
0
1
20
52
84
116
148
180
212
244
276
308
340
372
404
436
468
500
1
0
1
0
1
21
53
85
117
149
181
213
245
277
309
341
373
405
437
469
501
0
1
1
0
1
22
54
86
118
150
182
214
246
278
310
342
374
406
438
470
502
1
1
1
0
1
23
55
87
119
151
183
215
247
279
311
343
375
407
439
471
503
0
0
0
1
1
24
56
88
120
152
184
216
248
280
312
344
376
408
440
472
504
1
0
0
1
1
25
57
89
121
153
185
217
249
281
313
345
377
409
441
473
505
0
1
0
1
1
26
58
90
122
154
186
218
250
282
314
346
378
410
442
474
506
1
1
0
1
1
27
59
91
123
155
187
219
251
283
315
347
379
411
443
475
507
0
0
1
1
1
28
60
92
124
156
188
220
252
284
316
348
380
412
444
476
508
1
0
1
1
1
29
61
93
125
157
189
221
253
285
317
349
381
413
445
477
509
0
1
1
1
1
30
62
94
126
158
190
222
254
286
318
350
382
414
446
478
510
1
1
1
1
1
31
63
95
127
159
191
223
255
287
319
351
383
415
447
479
511
Dip Switch Position

7
DMX CHANNEL VALUE AND FUNCTION
Channel value Function
CH1 10~255 Auto program (slow to fast)
CH2 0~10 Motor 1 don,t move
11~127 Motor 1 Clockwise rotate
128~255 Motor 1 Counter rotate
CH3 0~10 Motor 2 don,t move
11~127 Motor 2 Clockwise rotate
128~255 Motor 2 Counter rotate
CH4 0~9 No function
10~255 Select gobo
TECHNICAL SPECIFICATIONS
Power supply 220V AC , 50/60Hz
Power consumption
25 W
Light source 5 LED (16R+16G+16B+16W)X2
LED rated life 50,000 hours
Control modes DMX512, Master/Slave,Sound active
Protection rating IP20
Working temperature -25 ~ +35
Fixture dimensions 390*360*110mm
Net weight 5kg
Please note: All information is subject to change without prior notice.

AMERICAN PRO
www.american-pro.com
develops & improves products constantly.
For this reason, the specifications and consigned information in the present
user manual can be modified without notice.
TRUSTING RESULTS
Table of contents
Other TECshow Lighting Equipment manuals

TECshow
TECshow HALO 1915 XL User manual

TECshow
TECshow Powerbox User manual

TECshow
TECshow MINI DERBY User manual

TECshow
TECshow NEBULA DUAL User manual

TECshow
TECshow RAINBOW LZ User manual

TECshow
TECshow SIRIUS IP User manual

TECshow
TECshow QUADBAR 16 IP User manual

TECshow
TECshow NEBULA FLAT 81 User manual

TECshow
TECshow HALO 715 XL User manual

TECshow
TECshow NEBULA FLAT 162 User manual