DECLARACIÓN DE CONFORMIDAD - DECLARATION OF CONFORMITY - DECLARAÇÃO DE CONFORMIDADE - DECLARATION DE
CONFORMITE - DICHIARAZIONE DI CONFORMITÀ - DEKLARACJA ZGODNOŚCI - KONFORMITÄTSERKLÄRUNG - ΠΙΣΤΟΠΟΙΗΤΙΚΟ
ΣΥΜΜΟΡΦΩΣΗΣ - FÖRSÄKRAN OM ÖVERENSSTÄMMELSE - VAATIMUSTENMUKAISUUSVAKUUTUS - ДЕКЛАРАЦИЯ СООТВЕТСТВИЯ -
ﺔﻘﺑﺎﻄﳌا نﺎﻴﺑ https://doc.televes.com
2016 © Copyright, Televés S.A.
Referencia Reference 108320
Banda de
trabajo Working
band MHz
470 - 698
CH 21 - 48 (EU)
CH 14 - 51 (USA)
Ganancia Gain dBi 13
Relación D/A F/B ratio dB 20
Carga al
viento Wind load N 139 (1)
191,5 (2)
Dimensiones Dimensions mm
in 807 x 560 x 206
31,77”x 22,05”x 8,11”
Peso Weight
Ominaisuus
Taajuusalue
Vahvistus
Etu/takasuhde
Tuulikuorma
Mitat
Paino
Referens
Frekvensband
Förstärkning
F/B-förhållande
Vindbelastning
Mått
Vikt g
lb
1343
2,96
(1) 80 miles/h - 130 Km/h
(2) 93 miles/h - 150 Km/h
ANSI/CEA-2028-A
Safety Instructions:
LIGHTNING PROTECTION
If installed outdoors, be sure the antenna system is grounded so as to
provide protection against voltage surges and built-up static charges.
Section 810 of the National Electrical Code ANSI/NFPA70, or CSA
C22.1 sections 10, 16, and 54, of the Canadian Electrical Code, provide
information with respect to proper grounding of the mast and supporting
structure, grounding of the antenna lead-in wire to an antenna discharge
unit, size of grounding conductors, location of antenna-discharge unit,
connection to grounding electrodes, and requirements for the grounding
Mount the lightning arrestor or 75 ohm coaxial grounding block as close
as possible to where the 75 ohm coaxial cable downlead enters the house.
The ground wires for both the mast and the downlead should be copper
or aluminum wire, number eight (8) or larger.
The downlead wire from the antenna to the lightning arrestor and the
mast ground wire should be secured to the house, spaced from four (4)
to six (6) feet apart.
In the case of a “ground up” antenna installation it may not be necessary
to ground the mast if the mast extends four or more feet in the earth.
Consult a TV serviceman for the proper depth in your location.
WARNINGS
to rain or moisture.
safety, follow the installation instructions.
with product instructions voids the warranty.
Antenna Lead
in Wire
Example of antenna grounding as per
National Electrical Code, ANSI/NFPA 70
NEC - National Electrical Code
Ground
clamp
Electric Service
Equipment
Ground clamps
Power service Grounding Electrode System
(NEC Art 250, Part H)
Antenna Discharge Unit
(NEC Section 810-20)
(May substitute a 75 ohm
Coax Grounding Block)
Grounding Conductors
(NEC Section 810-21)
78
Horizontal assembly / Montaje horizontal / Vaaka-asennus / Horisontell montering