Technical specications of the intelligent antenna (it must be powered)
Características técnicas de la antena inteligente (debe estar alimentada)
Ref. Ref. 149484
Working band Banda de trabajo MHz 174 - 216
(CH7 - CH13) 470 - 608
(CH14 - CH36)
Mode Modo INTELLIGENT (BOSS ON)
Gain Ganancia dBi 36.5 40
Output level Nivel de salida Auto (1)
Signal level of use (recomm.) Nivel de señal de uso (recomend.) dBμV < 75
Powering voltage Tensión de alimentación V 12
Consumption Consumo mA 70 (max) @12V
Beamwidth Ancho de haz º 60 40
F/B ratio Relación D/A dB >15 >20
Wind load Carga al viento N120 (@ 80 miles/h)
165 (@ 93 miles/h)
(1) The gain is automatically adjusted according to the output level / La ganancia varía automáticamente en función del nivel de salida.
Televes USA LLC. 16596 E. 2nd Avenue Aurora, CO 80011 USA televes.usa@televes.com www.televes.com
Safety Instructions:
LIGHTNING PROTECTION
If installed outdoors, be sure the antenna system is
grounded so as to provide protection against voltage
surges and built-up static charges. Section 810 of the
National Electrical Code ANSI/NFPA70, or CSA C22.1
sections 10, 16, and 54, of the Canadian Electrical Code,
provide information with respect to proper grounding
of the mast and supporting structure, grounding of
the antenna lead-in wire to an antenna discharge unit,
size of grounding conductors, location of antenna-
discharge unit, connection to grounding electrodes, and
requirements for the grounding electrode (see gure
and instructions).
Mount the lightning arrestor or 75 ohm coaxial
grounding block as close as possible to where the 75
ohm coaxial cable downlead enters the house.
The ground wires for both the mast and the downlead
should be copper or aluminium wire, number eight (8)
or larger.
The downlead wire from the antenna to the lightning
arrestor and the mast ground wire should be secured to
the house, spaced from four (4) to six (6) feet apart.
In the case of a “ground up” antenna installation it may
not be necessary to ground the mast if the mast extends
four or more feet in the earth. Consult a TV serviceman
for the proper depth in your location.
WARNINGS
To prevent re or shock hazard, do not expose the
included power supply to rain or moisture.
Installation of o-air antennas near power lines is
dangerous. For your safety, follow the installation
instructions.
Any alteration or modication to the product or usage
not in accordance with product instructions voids the
warranty.
Antenna Lead
in Wire
Example of antenna grounding as per
National Electrical Code, ANSI/NFPA 70
NEC - National Electrical Code
Ground
clamp
Electric Service
Equipment
Ground clamps
Power service Grounding Electrode System
(NEC Art 250, Part H)
Antenna Discharge Unit
(NEC Section 810-20)
(May substitute a 75 ohm
Coax Grounding Block)
Grounding Conductors
(NEC Section 810-21)
Application examples / Ejemplos de aplicación