Programming Summary
4INS 034-9
1Programming Summary
1.1 Programming Menu
Programming
Option
Option
Code
Programming
Procedure
Factory
Setting
Miscellaneous Selections Zero !! Select/De-select Option Number(s) "to *Press ,
Miscellaneous Selections One !" Select/De-select Option Number(s) "to *Press ,
Miscellaneous Selections Two !# Select/De-select Option Number(s) "to *Press ,
Miscellaneous Selections Three !$ Select/De-select Option Number "Press ,
Number of Alarm Activations !% Enter Number of Alarm Activations ++ Press ,03
Test Sounders, Strobe, SW+ !& Press &%$#" in turn Press -
Walk Test (Non-Latching) !' Conduct Walk Test Press -
Re-Load Factory Settings !) Press ,
Switched Positive Output !* Select Function "to *Press ,Set +Ve with Reset (6)
Configure Remote Keypads !( View Display Press ,
Zone 1 Zone Type "" Select Zone Type "to *Press ,Entry/Exit (6)
Zone 2 Zone Type "# Select Zone Type "to *Press ,Inhibited Entry (2)
Zone 3 Zone Type "$ Select Zone Type "to *Press ,Guard (3)
Zone 4 Zone Type "% Select Zone Type "to *Press ,Guard (3)
Zone 5 Zone Type "& Select Zone Type "to *Press ,Guard (3)
Zone 6 Zone Type "' Select Zone Type "to *Press ,Guard (3)
Zone 7 Zone Type ") Select Zone Type "to *Press ,Guard (3)
Zone 8 Zone Type "* Select Zone Type "to *Press ,Guard (3)
Walk Test (Latching) "( Conduct Walk Test Press -
Change into Entry/Exit Suite #" Select Zone Number(s) "to *Press ,Zone 2 Included
Change into Inhibited Entry Suite ## Select Zone Number(s) "to *Press ,No Zones Included
Change into Guard Suite #$ Select Zone Number(s) "to *Press ,Zone 1 Included
Program Current Date #& Enter Date DD/MM/YY Press ,
Program Current Time #' Enter Time HH:MM:SS Press ,
Program Service Timer 1 Date #) Enter Date DD/MM/YY Press ,
Program Service Timer 2 Date #* Enter Date DD/MM/YY Press ,
Program Service Timer 3 Date #( Enter Date DD/MM/YY Press ,
Full Set Exit Time (sec) $" Enter Exit Time ++ Press ,30 sec
Part Set Exit Time (sec) $# Enter Exit Time ++ Press ,30 sec
Full Set Entry Time (sec) $$ Enter Entry Time ++ Press ,30 sec
Part Set Entry Time (sec) $% Enter Entry Time ++ Press ,30 sec
Bell Cut-Off Time (min) $& Enter Cut-Off Time ++ Press ,15 min
Error Tone Suspension Time (sec) $' Enter Suspension Time ++ Press ,10 sec
Zone Soak Test time (days) $( Enter Soak Test Time ++ Press ,14 days
Clear Seven Event Basic Log %! Press ,
Basic Log Event 1 (most recent) %" View Display (Press .for Extended Display) Press -
Basic Log Event 2 %# View Display (Press .for Extended Display) Press -
Basic Log Event 3 %$ View Display (Press .for Extended Display) Press -
Basic Log Event 4 %% View Display (Press .for Extended Display) Press -
Basic Log Event 5 %& View Display (Press .for Extended Display) Press -
Basic Log Event 6 %' View Display (Press .for Extended Display) Press -
Basic Log Event 7 (least recent) %) View Display (Press .for Extended Display) Press -
Zone Disable Suite %* Select Zone Number(s) "to *Press ,No Zones Included
Zone Soak Test Suite %( Select Zone Number(s) "to *Press ,No Zones Included
Part Set Suite 1 &" Select Zone Number(s) "to *Press ,Zones 5, 6, 7 Omitted
Part Set Suite 2 &# Select Zone Number(s) "to *Press ,Zones 5, 6, 7 Omitted
Chime Suite && Select Zone Number(s) "to *Press ,No Zones Included
Double Knock Suite &) Select Zone Number(s) "to *Press ,No Zones Included
Manual Omit Suite &* Select Zone Number(s) "to *Press ,Zone 1 Omitted
Program Your Own Code PIN '! Enter New Code PIN ++++ Press ,
Display Panel Type )! View Display Press -Z1, Z4 On