tibelec 0900001 User manual

Top-testeur REF 0900001/
EM5893
VIM : 23521_21W01
6F22 9V
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
tibelec
0900001
FR/ Testeur digital - GB/ Digital tester - ES/ Probador digital
IT/ Tester digitale - PT/ Testador digital - DE/ Digitales Prüfgerät
NL/ Digitale tester - PL/ Cyfrowy tester - RO/ Tester digital -
GR/ Ψηφιακό πολύμετρο
FR/ Notice d’utilisation - GB/ Instructions
ES/ Manual de uso - IT/ Istruzioni per l’uso
PT/ Manual de instruções - DE/ Gebrauchsanweisung
NL/ Instructies voor gebruik - PL/ Instrukcje użytkowania
RO/ Instrucțiuni de utilizare - GR/ οδηγίες χρήσης

FR
2
Avertissement :
1. Soyez particulièrement prudent en présence de tensions supérieures à 30VACrms
ou 60VDC pour éviter des dommages ou électrocutions
2. Ne jamais appliquer une valeur d’entrée supérieure à la valeur maximum de la
gamme autorisée par le fabricant de l’appareil. Ce testeur est destiné à des appli-
cations de basse tension. (600V MAXI EN ALTERNATIF/CONTINU )
3. Ne jamais utiliser le testeur pour mesurer la ligne alimentant un appareil qui
génère une montée subite de la tension puisqu’elle peut excéder la tension
maximale permise (exemple des moteurs)
4. Ne jamais utiliser le testeur si les pointes ou cordons de mesure sont endomma
gés ou cassés. Veillez à ce qu’ils ne soient jamais humides ou mouillés ; vériez
le bon état de fonctionnement du testeur et celui des cordons avant sa mise en
service.
5. L’ouverture du boîtier donne accès à des parties conductrices de tensions dange-
reuses. Toute action sur les circuits internes pourrait entraîner une utilisation
dangereuse. Ne jamais utiliser le testeur démonté. Avant d’utiliser votre testeur :
vériez que le boîtier est bien fermé et vissé.
6. Laissez toujours vos doigts derrière la garde des pointes test lors des mesures.
Veillez au cours de la mesure à ne pas entrer en contact (par les doigts par
exemple) directement ou indirectement avec les parties conductrices de tensions
élevées.
7. Avant toute intervention (changement de piles, par exemple) ou avant de tourner
le sélecteur rotatif pour changer de fonction, déconnectez les pointes des cordons
de toute source de tension et du circuit à mesurer et éteindre le testeur.
8. Avant d’effectuer une mesure, assurez-vous que le sélecteur de fonction est en
position correcte.
IMPORTANT : ces instructions sont pour votre sécurité.
Lisez les attentivement avant utilisation et conservez-les
pour une utilisation ultérieure.

1. Afchage LCD
2. Touche marche/arrêt
3. Commutateur de fonction
4. Jack Acordon rouge
5. Jack mAΩ cordon rouge
6. Zone de détection sans contact
7. Housse anti choc
8. Touche HOLD
9. Touche éclairage écran
10. Jack Vcordon rouge
11. Jack COM cordon noir
3
• Afchage LCD, lecture maxi 1999.
• Commutateur de fonction : voltmètre alternatif, voltmètre continu, test de transistor,
ampèremètre continu, ampèremètre alternatif, capacimètre, test de diode et
continuité avec buzzer, ohmmètre, NCV.
• NCV : zone de détection courant alternatif sans contact.
• HOLD : mémorise la mesure en cours, la valeur afchée sera mémorisée. Appuyez
sur la touche HOLD pour garder la mesure en cours et appuyez de nouveau sur la
touche pour revenir en mode normal.
• Eclairage écran lumière orange, s’éteint automatiquement aprés 15 secondes.
1. Mesure alternative
2. Polarité négative
3. Diode, buzzer
4. Transistor
5. Symbole batterie faible
6. Capacimètre
7. Voltmètre
8. Ampèremètre
9. Ohmmètre
1
2
3
4
5
6
7
8
9
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
tibelec
0900001
1
2
3
4
5
7
8
9
10
11
6
Si le calibre à mesurer n’est pas connu à l’avance, réglez le commutateur
sur le calibre le plus haut et réduire progressivement jusqu’au calibre voulu.
3

V
DC
Voltmètre
Tension continue DC
V~
AC
Voltmètre
Tension alternative AC
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
V~
200 600 600 200
20
0900001
A
DC
Ampéremètre
Intensité continue DC
Utilisation :
A~
AC
Ampéremètre
Intensité alternative AC
Ohmmètre (résistance)
Ω
2V 1mV
20V 10mV +(1,0%+5)
200V 100mV
600V 1V +(1,5%+5)
Calibre Resolution Précision
200mV 0,1mV
2V 1mV
20V 10mV
+(0,8%+5)
200V 100mV
600V 1V +(1,0%+5)
200Ω 0,1Ω +(1,2%+5)
2KΩ 1Ω
20KΩ 10Ω +(1,0%+5)
200KΩ 100Ω
2MΩ 1KΩ
20MΩ 10KΩ +(1,5%+5)
200MΩ 100KΩ + 6%*
4
2mA 1µA +(1,5%+5)
20mA 10µA
200mA 100µA
10A 10mA +(3,0%+7)
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
V
00 600 600 200 20
+
-
0900001
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
0900001
A~
2
10
10
200m
20m
m
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
A
A
20
200m
10
10
200m
0m
+
-
batterie
0900001
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
2M
20M
200M
NCV
2
20
0900001
* + (6% x (lecture - 10) +10)
2mA 1µA +(1,2%+5)
20mA 10µA
200mA 100µA
10A 10mA +2,0%+5)

1. Reliez la sonde noire à la borne COM et la sonde rouge à la borne V
2. Mettez le commutateur de fonction sur le calibre de tension alternative voulu
3. Connectez les pointes test sur le circuit et lisez la valeur indiquée à l’écran quand
elle est stabilisée.
5
1. Reliez la sonde noire à la borne COM et la sonde rouge à la borne V
2. Mettez le commutateur de fonction sur le calibre de tension continue voulu
3. Connectez les pointes test sur le circuit et lisez la valeur indiquée à l’écran quand
elle est stabilisée. Lorsque vous mesurez une tension continue, l’écran afche la
polarité de la sonde rouge.
1. Reliez la sonde noire à la borne COM et la sonde rouge à la borne
mAΩ
pour une mesure maxi de 200mA ou à la borne Apour une mesure maxi de 10A
2. Mettez le commutateur de fonction sur le calibre de l’intensité alternative voulu
3. Connectez les pointes test sur le circuit et lisez la valeur indiquée à l’écran quand
elle est stabilisée.
1. Reliez la sonde noire à la borne COM et la sonde rouge à la borne
mAΩ
pour une mesure maxi de 200mA ou à la borne Apour une mesure maxi de 10A
2. Mettez le commutateur de fonction sur le calibre de l’intensité continue voulu
3. Connectez les pointes test sur le circuit et lisez la valeur indiquée à l’écran quand
elle est stabilisée.
Lorsque vous mesurez une intensité continue, l’écran afche la
polarité de la sonde rouge.
1. Reliez la sonde noire à la borne COM et la sonde rouge à la borne
mAΩ
2. Mettez le commutateur de fonction sur le calibre de résistance voulu
3. Connectez les pointes test sur le circuit et lisez la valeur indiquée à l’écran quand
elle est stabilisée.

Transistor
Capacimètre
Continuité avec buzzer
hFE
Diode
2nF 1pF
20nF 10pF
200nF 100pF +(5,0%+5)
2µF 1nF
20µF 10nF
200µF 100nF +(6,0%+10)
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
200m
200µ
2µ F
200n
20n
NPN PNP
K
0900001
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
A
2
20m
2m
00
cathode (-)
anode (+)
A
B
V~ V
A
A~
Ω
200 600
600
200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
2µ F
200n
20n
hFE
2m
20m
NPN PNP
K
0900001
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
20m
2m
200
2k
6
NCV
Détection de tension
alternative sans contact
V~ V
A
A
~
Ω
200 600 600200 20
2
200m
200µ
2µ
F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2
m
200
2k
20k
20
0k
2M
20M
200M
NCV
2
20
H
COM
!
V
TIII 600V
tibelec
lec
ibelec

1. Mettez le commutateur de fonction sur la position F
2. Branchez l’adaptateur transistor sur la borne COM et sur la borne mAΩ
3. Déchargez complètement le condensateur à mesurer, puis branchez-le dans
l’adaptateur
4. Lisez la valeur indiquée à l’écran quand elle est stabilisée.
1. Reliez la sonde noire à la borne COM et la sonde rouge à la borne
mAΩ
2. Mettez le commutateur de fonction sur la position
3. Connectez les pointes test sur la diode :
(A) Test dans le sens direct : connectez la pointe noire sur la cathode et la pointe rouge
sur l’anode, en mesurant la tension dans le sens passant d’une diode normale, l’écran
indiquera entre 0,5 et 0,7V et le sens bloqué indiquera «1»
(B) Test dans le sens inverse : connectez la pointe noire sur l’anode et la pointe rouge
sur la cathode. La diode est bonne si l’écran indique «1».
1. Mettez le commutateur de fonction sur la position hFE
2. Branchez l’adaptateur transistor sur la borne COM et sur la borne mAΩ
3. Connectez le transistor dans les trous appropriés de l’adaptateur selon le type du
transistor NPN ou PNP
4. Lisez la valeur indiquée à l’écran quand elle est stabilisée.
1. Reliez la sonde noire à la borne COM et la sonde rouge à la borne
mAΩ
2. Mettez le commutateur de fonction sur la position
3. Connectez les pointes test sur le circuit et si la résistance du circuit < 30Ω,
le buzzer sonnera et le symbole s’afchera à l’écran.
7
1. Mettez le commutateur de fonction sur la position NCV
2. Rapprochez le haut du testeur vers la zone à tester. Lorsqu’il détecte une tension
alternative, le buzzer intégré retentit et un voyant rouge s’allume.

8
Remplacement de la pile :
Le consommateur est tenu par la loi de recycler toutes les piles et tous les
accumulateurs usagés. Il est interdit de les jeter dans la poubelle ordinaire !
Reportez-vous aux précisions relatives à la protection de l’environnement.
Quand le symbole apparaît vous devez remplacer la pile
par une nouvelle.
1. Mettez le sélecteur sur Off
2. Dévissez la vis à l’arrière de l’appareil
3. Ouvrez et remplacez la pile dans la zone correspondante
par une pile de même type (6F22 9V).
4. Revissez.
+
-
Modèle n°EM5893
- Extinction automatique aprés 15 minutes de non fonctionnement
- Températures pour le fonctionnement : 0°C~40°C
- Températures de stockage : -10°C~ 50°C
- 2 fusibles de protection : 400mA 690V - 10A 690V
- Dimensions et Poids : 54x91x190mm / 435gr (avec la pile)
- Niveau de sécurité : 600V CAT III.
Classe II : matériel double
isolation, dispensé de raccord
à la terre
Les produits électriques usagés
ne doivent pas être jetés
avec les ordures ménagères.
Veuillez utiliser les aménage-
ments spécifiques prévus pour
les traiter.
Protégé par fusibles
standards
Certié conforme aux
normes européennes
Risques résultants de
tensions dangereuses

9
TIBELEC GARANTIT LA QUALITE ET LA FIABILITE DE CE PRODUIT ; IL FAIT PARTIE
DES ARTICLES SOUS GARANTIE LEGALE D’UNE DUREE DE 2 ANS POUR DEFAUTS
ET VICES CACHES CONFORMEMENT AUX ARTICLES 1641 A 1648 DU CODE CIVIL.
Tibelec ne pourra pas être tenu responsable des dommages causés suite à une
mauvaise utilisation, mauvais entretien, un détournement de l’utilisation de ce pro-
duit, l’usure normale, bris par chute, ouverture de l’appareil. Tibelec ne pourra pas
accepter en retour les produits pour remplacement des consommables nécessaires à
l’utilisation de ce produit. Le remplacement des consommables est à votre charge.
Importé par tibelec 996 rue des hauts de Sainghin CRT4
59262 Sainghin en Mélantois - France

10
Warning:
1. Be particularly careful when using voltages above 30V AC (RMS) or 60V DC to
avoid damage or electric shock.
2. Never apply an input voltage higher than the maximum value of the range allowed
by the device manufacturer. This monitor is designed for low voltage applications.
(600V MAX IN AC/DC)
3. Never use the tester to measure the line feeding a device that generates a sudden
surge in voltage as it may exceed the maximum permitted voltage (e. g. motors).
4. Never use the tester if the test plungers or leads are damaged or broken. Make
sure they are never wet or damp; check that the tester and the leads are working
properly before commissioning.
5. Opening the housing gives access to hazardous voltage conductive parts. Any
action on internal circuits could result in hazardous use. Never use the disassem
bled tester. Before using it: check that the housing is properly closed and screwed
in.
6. Always make sure your ngers are behind the test plunger guard during measure
ments. During the measurement, be careful not to come into direct or indirect
contact (e. g. with ngers) with high voltage conductive parts.
7. Be sure to disconnect the plungers of the leads from any voltage source and the
circuit to be measured; remove the plungers when changing function. Before per
forming any work (e. g. changing batteries) or before turning the rotary switch to
change functions, disconnect the tester.
8. Before taking a measurement, make sure the function selector switch is in the
correct position.
IMPORTANT: these instructions are for your safety. Read
them carefully before use and keep them for future use.
GB

1. LCD display
2. On/off push button
3. Function switch
4. Jack Ared test leads
5. Jack mAΩ red test leads
6. Contactless detection zone
7. Holster
8. HOLD push button
9. Blacklit screen push button
10. Jack Vred test leads
11. Jack COM black test leads
11
• LCD display, max 1999-digit reading.
• Function switch : Voltmeter AC, Voltmeter DC, transistor test, Ammeter DC,
Ammeter AC, Capacitance, diode test and continuity with buzzer, Ohmmeter, NCV.
• NCV : contactless alternating current detection area.
• HOLD : saves the current measurement, the displayed value will be saved. Press
the HOLD key to keep the current measurement and press the key again and hold
to return to normal mode.
• Screen lighting : orange light, automatically turns off after 15 seconds.
1. AC measurement
2. Negative polarity
3. Diode, buzzer
4. Transistor
5. Low battery symbol
6. Capacitance
7. Voltmeter
8. Ammeter
9. Ohmmeter
1
2
3
4
5
6
7
8
9
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
tibelec
0900001
1
2
3
4
5
7
8
9
10
11
6
If the rating to be measured is not known in advance, set the
switch to the highest rating and gradually reduce to the desired
rating

V
DC
Voltmeter DC
V~
AC
Voltmeter AC
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
V~
200 600 600 200
20
0900001
A
DC
Ammeter DC
Use :
A~
AC
Ammeter AC
Ohmmeter (resistance)
Ω
2V 1mV
20V 10mV +(1,0%+5)
200V 100mV
600V 1V +(1,5%+5)
Range Resolution Accuracy
200mV 0,1mV
2V 1mV
20V 10mV
+(0,8%+5)
200V 100mV
600V 1V +(1,0%+5)
200Ω 0,1Ω +(1,2%+5)
2KΩ 1Ω
20KΩ 10Ω +(1,0%+5)
200KΩ 100Ω
2MΩ 1KΩ
20MΩ 10KΩ +(1,5%+5)
200MΩ 100KΩ + 6%*
12
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
V
00 600 600 200 20
+
-
0900001
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
0900001
A~
2
10
10
200m
20m
m
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
A
A
20
200m
10
10
200m
0m
+
-
batterie
0900001
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
2M
20M
200M
NCV
2
20
0900001
* + (6% x (reading - 10) +10)
2mA 1µA +(1,5%+5)
20mA 10µA
200mA 100µA
10A 10mA +(3,0%+7)
2mA 1µA +(1,2%+5)
20mA 10µA
200mA 100µA
10A 10mA +2,0%+5)

1. Connect the black probe to terminal COM and the red probe to terminal V
2. Set the function switch to the desired AC voltage rating
3. Connect the test plungers to the circuit and read the value displayed on screen
once it has stabilised.
13
1.
Connect the black probe to terminal COM and the red probe to terminal V
2.
Set the function switch to the desired DC voltage rating
3.
Connect the test plungers to the circuit and read the value displayed on screen
once it has stabilised.
When measuring DC voltage, the display shows the polarity
of the red probe
.
1.
Connect the black probe to terminal
COM
and the red probe to terminal
mAΩ for a maximum measurement of 200mA or at the Aterminal for a maximum
measurement of 10A
2.
Set the function switch to the desired AC current rating
3.Connect the test plungers to the circuit and read the value displayed on screen
once it has stabilised.
1.
Connect the black probe to terminal
COM
and the red probe to terminal
mAΩ for a maximum measurement of 200mA or at the Aterminal for a maximum
measurement of 10A
2.
Set the function switch to the desired DC current rating
3. Connect the test plungers to the circuit and read the value displayed on the screen
once it has stabilised. When measuring DC current, the display shows the polarity of
the red probe
.
1.
Connect the black probe to terminal
COM
and the red probe to terminal
mAΩ
2.
Set the function switch to the desired resistance rating
3. Connect the test plungers to the circuit and read the value displayed on
screen once it has stabilised.

Transistor
Capacitance
Continuity with buzzer
hFE
Diode
2nF 1pF
20nF 10pF
200nF 100pF +(5,0%+5)
2µF 1nF
20µF 10nF
200µF 100nF +(6,0%+10)
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
200m
200µ
2µ F
200n
20n
NPN PNP
K
0900001
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
A
2
20m
2m
00
cathode (-)
anode (+)
A
B
V~ V
A
A~
Ω
200 600
600
200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
2µ F
200n
20n
hFE
2m
20m
NPN PNP
K
0900001
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
20m
2m
200
2k
NCV
Contactless alternating
current detection area
V~ V
A
A~
Ω
200 600 600200 20
2
200m
200µ
2µ
F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2
m
200
2k
20k
2
00k
2M
20M
200M
NCV
2
20
H
COM
!
V
TIII 600V
tibelec
lec
ibelec
14

1. Set the function switch to position F
2. Connect the transistor adapter to terminal COM and to terminal mAΩ
3. Completely discharge the capacitor to be measured, then plug it into the adapter
4. Read the value displayed on screen once it has stabilised
1.
Connect the black probe to terminal COM and the red probe to terminal mAΩ
2.
Set the function switch to position
3.
Connect the test plungers to the diode
:
(A) Test in the direct direction: connect the black plunger to the cathode and the red
plunger to the anode, measuring the voltage in the direction of a normal diode; the
screen will display 0.5 to 0.7V and the blocked direction will display “1”.
(B) Test in the opposite direction: connect the black plunger to the anode and the
red plunger to the cathode. The diode is good if the display shows “1”.
1. Set the function switch to position hFE
2. Connect the transistor adapter to terminal COM and to terminal mAΩ
3. Connect the transistor into the appropriate holes of the adapter depending on the
type of NPN or PNP transistor
4. Read the value displayed on screen once it has stabilised
1.
Connect the black probe to terminal COM and the red probe to terminal mAΩ
2.
Set the function switch to position
3. Connect the test plungers to the circuit and if the resistance is < 30Ω, the audible
signal will sound and the display shows .
1.
Set the function switch to position
NCV
2. Move the tester closer to the area to be tested. When it detects an AC voltage, the
buzzer sounds and a red light comes on.
15

16
Replacing the battery :
The consumer is obliged by law to recycle all used batteries and accumula-
tors. It is forbidden to throw them in the ordinary bin! Refer to the environ-
mental protection details.
When the symbol appears , replace the battery with a
new one :
1. Set the function switch to Off
2. Loosen the screw on the back of the tester
3. Open and replace the battery in the corresponding area with
a battery of the same type (6F22 9V)
4. Tighten again.
+
-
Model n°EM5893
-
Auto power off : meter automatically shuts down after approx. 15 minutes of inactivity
- Rating temperature : 0°C~40°C
- Operating temperature : -10°C~ 50°C
- Size and weight : 54x91x190mm / 435gr (with battery)
- Safety standard : 600V CAT III.
Protected by
standard fuse
Certied in accordance
with European stan-
dards
Risks resulting from
hazardous voltages
Class II equipment
without ground
connection
Do not dispose of appliances
bearing this symbol with
domestic waste. Use a suitable
collection point.

Imported by tibelec 996 rue des hauts de Sainghin CRT4
59262 Sainghin en Mélantois - France
17
Tibelec guarantees the quality and reliability of this product’s components: this item is
legally required to be accompanied by a 2-year warranty for aws and latent defects
in accordance with articles 1641 to 1648 of the Civil Code. Our technical support
Tibelec cannot be held liable for damage caused by incorrect use, poor maintenance,
misuse of the product, normal wear and tear, damage from falls, or opening of the
xture. Tibelec cannot accept returns for replacement of the consumable items that
are required for the use of this product. The replacement of consumable items is your
responsibility.

18
ES
Advertencia :
1. Tenga especial cuidado cuando utilice tensiones superiores a 30 V CA (RMS)
o 60 V CC para evitar daños o descargas eléctricas.
2. Nunca aplique un valor de entrada superior al valor máximo del rango permitido
por el fabricante del dispositivo. Este controlador está diseñado para aplicaciones
de baja tensión. (600V MAX EN CA/CC)
3. No utilice nunca el aparato para medir la línea que alimenta un dispositivo
que genera una sobretensión, ya que puede superar la tensión máxima permitida
(p. ej., motores).
4. Nunca utilice el probador si las sondas de prueba o los cables de prueba están
dañados o rotos. Asegúrese de que no estén húmedos o mojados; compruebe
el correcto funcionamiento del probador y de los cables antes de ponerlos en
marcha.
5. La apertura de la carcasa da acceso a piezas conductoras de valores de tensión
peligrosos. Cualquier acción en los circuitos internos puede resultar en un uso
peligroso. Nunca utilice el probador desmontado. Antes de utilizarlo: compruebe
que la carcasa esté bien cerrada y atornillada.
6. Mantenga siempre los dedos detrás de la protección de la sonda de prueba
durante las medidas. Durante la medición, tener cuidado de no entrar en contacto
directo o indirecto (p. ej. con los dedos) con las piezas conductoras de alta tensión.
7. Asegúrese de desconectar las sondas de los cables de cualquier fuente de tensión
y del circuito que se va a medir, retire las sondas cuando cambien de función.
Antes de realizar cualquier trabajo (por ejemplo, cambiar las pilas) o antes de girar
el selector para cambiar las funciones, desconecte el aparato.
8. Antes de realizar una medición, asegúrese de que el selector de funciones esté en
la posición correcta.
IMPORTANTE: estas instrucciones son para su seguridad. Léalas
cuidadosamente antes de utilizar el aparato y guárdelas para un
futuro uso.

1. Pantalla LCD
2. Tecla de encendido / apagado
3. Conmutador de funciones
4. Clavija Acable rojo
5. Clavija mAΩ cable rojo
6. Zona de detección sin contacto
7. Cubierta a prueba de golpes
8. Tecla HOLD
9. Tecla de luz de pantalla
10. Clavija Vcable rojo
11. Clavija COM cable negro
19
• Pantalla LCD, lectura máxima de 1999 dígitos.
• Conmutador de funciones : Voltímetro alterno, Voltímetro continuo, prueba
de transistor, Amperímetro continuo, Amperímetro alterno, Condensador, prueba
de diodo y continuidad con zumbador, Ohmímetro, NCV.
• NCV : área de detección de corriente alterna sin contacto.
• HOLD : almacena la medición en progreso, el valor visualizado será memorizado.
Presione la tecla HOLD para mantener la medición actual y presione la tecla
nuevamente y mantenga presionada para volver al modo normal.
• Iluminación de pantalla de luz naranja, se apaga automáticamente después de
15 segundos
1. Medida alterna
2. Polaridad negativa
3. Diode, zumbador
4. Transistor
5. Símbolo de batería baja
6. Condensador
7. Voltímetro
8. Amperímetro
9. Ohmímetro
1
2
3
4
5
6
7
8
9
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
tibelec
0900001
1
2
3
4
5
7
8
9
10
11
6
Si no se conoce de antemano el calibre a medir, ponga el interruptor en
el calibre más alto y redúzcalo gradualmente hasta el calibre deseado

V
DC
Voltímetro DC
Tensión continua
V~
AC
Voltímetro AC
Tensión alterna
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
V~
200 600 600 200
20
0900001
A
DC
Amperímetro DC
Intensidad continua
Uso :
A~
AC
Amperímetro AC
Intensidad alterna
Resistencia (Ohmímetro)
Ω
2V 1mV
20V 10mV +(1,0%+5)
200V 100mV
600V 1V +(1,5%+5)
Calibre Resolución Precisión
200mV 0,1mV
2V 1mV
20V 10mV
+(0,8%+5)
200V 100mV
600V 1V +(1,0%+5)
200Ω 0,1Ω +(1,2%+5)
2KΩ 1Ω
20KΩ 10Ω +(1,0%+5)
200KΩ 100Ω
2MΩ 1KΩ
20MΩ 10KΩ +(1,5%+5)
200MΩ 100KΩ + 6%*
20
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
V
00 600 600 200 20
+
-
0900001
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
0900001
A~
2
10
10
200m
20m
m
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
A
A
20
200m
10
10
200m
0m
+
-
batterie
0900001
V~ V
A
A~
Ω
200 600 600 200 20
2
200m
200µ
2µ F
200n
20n
hFE
2m
20m
200m
10
10
200m
20m
2m
200
2k
20k
200k
2M
20M
200M
NCV
2
20
H
A
COM
mAΩ
!!!
V
FUSED
10A~MAX.
10 sec MAX.
EACH 15min
FUSED
MAX
200mA~
MAX
600V~
CATIII 600V
2M
20M
200M
NCV
2
20
0900001
* + (6% x (leyendo - 10) +10)
2mA 1µA +(1,5%+5)
20mA 10µA
200mA 100µA
10A 10mA +(3,0%+7)
2mA 1µA +(1,2%+5)
20mA 10µA
200mA 100µA
10A 10mA +2,0%+5)
Table of contents
Languages:
Other tibelec Test Equipment manuals