Toyotomi ETK-S50 User manual

AIR PURIFIER
INSTRUCTION MANUAL
English
Thank you for purchasing our product.
■Before using this product, be sure to read this Instruction Manual to ensure proper usage. Please
keep this manual for later reference.
■Improper use of this product may result in a malfunction, failure, unexpected accident, or create a
potential hazard.
MODEL
ETK-S50
ETK-S50 (GB) 10.6.22 9:03 AM ページ a

1. SAFETY PRECAUTIONS
3. NAME OF COMPONENT PARTS
4. PREPARATION BEFORE USE
1 HOW TO INSTALL THE FILTERS
2 HOW TO INSTALL AIR PURIFIER
3 HOW TO INSERT BATTERIES INTO THE REMOTE CONTROL
5. OPERATION PROCEDURE
OPERATION BY OPERATION PANEL
1 ON / OFF AUTOMATIC OPERATION CHANGING THE OPERATION MODE
OPERATION BY REMOTE CONTROL
1 ON / OFF AUTOMATIC OPERATION CHANGING THE OPERATION MODE
2 TIMER OPERATION
3 SMOKING OPERATION
4 POLLEN OPERATION
6. ROUTINE MAINTENANCE
7. TROUBLESHOOTING
8. SPECIFICATIONS
··········································································1~4
··································································5~7
······································································8
····························································8
···························································9
·····························9
·····································································10~15
···························································10
···········10~11
···························································12
··············12
·········································································13
·····································································14
·······································································15
······································································16~18
···············································································19
···················································································20
CONTENTS
ETK-S50 (GB) 10.6.22 9:03 AM ページ b

1
SAFETYPRECAUTIONS(Pleasereadcarefullyandfollowallinstructions.)
●ItemsshownherearelabeledWarning!andCaution!
Besuretofollowthewarningsandcautionsastheyexplainimportantdetailsregardingsafety.
Improperusecancausedeathorseriouspersonalinjury.
Improperusecancausepersonalinjuryorphysicaldamage.
●Besuretofollowtheadviceintheinstructionmanualinordertousethisunitproperly.
WARNING
CAUTION
WARNING
CAUTION
★Onlyauthorizedtechniciansshoulddisassemble,repair,ormodifythisproduct.
● Ignitionormalfunctionmayoccur,causinginjury.
★Besure toremove thepower plugfrom theelectrical outletwhen performing
maintenance.Donotremoveorinserttheplugwithwethands.
● Failuretoheedthiswarningmayresultinelectricshockorburns.
★NoothercurrentthanAC230Visallowedtobeused.
● Whenusedonanythingotherthan230Vmains,fireorelectricshockmayoccur.
★Nodamagedpowercord,plug,orlooseplugconnectionisallowedtobeused.
● Anelectricshock,short,orinflammationmayotherwisebecaused.
★Donotdamage,break,modify,forciblybend,yank,twist,or
bundlethepowercord.
● A fire or electric shock may result if the cord is pinched or
modified,orsomethingheavyisplacedonit.
Caution Mustbe
performed.
Removethepowerplug
fromtheelectricoutlet.
Donot
disassemble.
English
ETK-S50 (GB) 10.6.22 9:03 AM ページ 1

2
CAUTION
★Removealldustanddirtfromthepowerplugandinsertit
completelyintotheoutlettoensurepropercontact.
● Dust and dirt on the plug or incomplete insertion creates the
dangerofelectricalshockandfire.
★When unplugging the power plug, grip the plug and not
thecord.
● Donotpullthecordorthewireinsidethecordwillbedamaged
resultinginheatorignition.
★IftheAirPurifierisnotusedforalongtime,removethepowerplugfromthe
outlet.
● Caked-ondustmaycauseheatorignition.
★
DonotexposetheproducttoflammablesubstancesorHeavysmokeorincense.
● Thismaycauseafire.
★Donotusetheunitwheretheatmospherecontainsoil.
● Thismaycauseacrack.
★TheAirPurifierisnotallowedtobeusedinsuchamoist
placeasabathroom.
● Anelectricshockormalfunctionmayoccur.
★Caremust be taken not toput your finger or anyforeign
materialintotheSuctionGrilleortheAirOutlet.
● Anelectricshockortroublemayoccur.
★Donotexposeyourbodytotheaircurrentfromtheexhaustports.
● Suchaircurrentmayharmhumanhealth,especiallyinfants,theelderly,andthesick.
SAFETYPRECAUTIONS(Pleasereadcarefullyandfollowallinstructions.)
ETK-S50 (GB) 10.6.22 9:03 AM ページ 2

3
CAUTION
★Do not expose the unit to vapor or mist from
somethinglikeahumidifierorelectricshockorfailure
mayresult.(Use the unitsothat the main unitisnot
exposedtovaporormistfromahumidifier.)
★Do not wipe the unit with benzene or paint thinner.
Also,donotsprayinsecticidesontheunit.
● Cracking, electrical shock and / or fire may occur as a
result.
★CleanthePrefilterperiodically(morethanonceevery
twoweeks).
● If the Prefilter is continuously used and accumulates, an
excessiveamountofcottonwaste,theAirPurifiermaybe
subjectedtoinflammationormalfunction.Besurealsoto
alwaysusethePrefilterforAirPurifieroperation.
★Do not wash and reuse a dirty enzyme HEPA filter
and/or activated carbon filter, which will result in an
electric shock or fire. Air cleaning function will not
recoverevenifthefiltersarewashed.
★Donotusetheunitwiththeintakeandexhaustports
blocked or obstructed; doing so will result in
deformationand/orfailure.
★Whenusingwithanothercombustionappliance,ventilationisnecessary.
● Theunitcannotaddoxygenorremovecarbonmonoxide.Toxicsubstances(suchas
carbonmonoxide)containedintobaccocannotberemoved.
★Donotuseinwindyorbreezylocations.
● IftheAirPurifierisinstallednearadoor,windorsudden
temperature changes from the door opening and closing
maycausethesensorstomalfunction,affectingautomatic
operation.
SAFETYPRECAUTIONS(Pleasereadcarefullyandfollowallinstructions.)
English
ETK-S50 (GB) 10.6.22 9:03 AM ページ 3

4
CAUTION
★Do not use the unit in places where inverter
lighting equipment and/or electronic instant-on
lampsarenearby or where theunitis exposed
todirectsunlight.
● Thismaypreventthefunctionoftheremotecontrol,
resultinginoperationproblemsormalfunctions.
★Place the Air Purifier more than 1m away from
thetelevisionsetandtheradio.
● The Air Purifier may otherwise be subjected to
electricwavehazards.
★Do not use the unit on or around a space-
heating appliance or where it may be exposed
toheat.Thismaycauseafailureordeformation.
★Donotusetheunitinplaceswithgreasydirtor
excessive moisture such as a kitchen or a
factory.
● Doing so may cause a failure or degradation of
cleaningability.
★Donotexposetheunittoflammablegas.Doingsomaycauseanexplosionora
fire.
★Do not install the Air Purifier on an unstable
floor,shelforwall.
● ThereisafearoftheAirPurifierfallingdown.
Morethan1m
SAFETYPRECAUTIONS(Pleasereadcarefullyandfollowallinstructions.)
★Theapplianceisnottobeusedbychildrenorpersonswithreducedphysical,sensoryor
mental capabilities, or lack of experience and knowledge, unless they have been given
supervisionorinstruction.
ETK-S50 (GB) 10.6.22 9:03 AM ページ 4

FILTERUNITINSIDEOFTHEMAINUNIT
MAINUNIT
RemoteControl
Battery(2pcs.)
〔R03〕
ACCESSORIES
ActiveCharcoalFilter(DeodorantFilter)
Thisfilterabsorbsfoulodors.
EnzymeHEPAFilter(BactericidalFilter)
Thisfilternotonlyremovescigarettesmoke,
pollen,orsmalldustbutalsoeliminatesbacteria.
Prefilter
Thisfilterremoveslarge-sizeddust.
NAMEOFCOMPONENTPARTS
OperationButton
FrontPanel
AirOutlet
AirOutlet
PowerPlug
Button
5
English
ETK-S50 (GB) 10.6.22 9:03 AM ページ 5

6
RESETBUTTON
Pressthebuttontostartoperation.Theairvolumechangeswitheverypush.
Ion
+
Auto
Ion
+
Quiet
Ion
+
Standard
Ion
+
High
Ion
+
Rapid
Stop
DISPLAY/CONTROLPANEL
REMOVETHEFRONTPANEL
OPERATIONBUTTON
OdorSensor
Press this button after the enzyme HEPA filter is
replaced. When the filter lamp lights, replace the
enzymeHEPAfilter.Pleasereplacethefilterevery
fiveyearsorso.
NAMEOFCOMPONENTPARTS
ETK-S50 (GB) 10.6.22 9:03 AM ページ 6

7
TRANSMITTINGPARTOF
REMOTECONTROL
Sends operation signals to the Remote
Control receptor on the main unit. The
effectiveRemoteControliswithinabout
7metersdirectlyfromthefront.
ON/OFFBUTTON
Press the button to start operation and
push the same button again to stop
operation. The operation starts with
automatic operation mode and Auto
lamp(Green)lights.
FANSPEEDBUTTON
Pressthebutton
Theoperationmodechangesasshown
above;theautomaticoperationindicator
lamp and fan-speed indicator lamp will
light according to changes in operation
andfanspeed.
TIMERBUTTON
TheTimerButtonisusedtoset
and erase the time-off for
operation. The Timer Lamp
(Green)lightsup.
SMOKINGBUTTON
WhenSmokingbuttonispressed,
the Smoking operation starts
andtheSmokinglamp(Green)
lightsup.
POLLENBUTTON
WhenPollenbuttonispressed,
thePollenoperationstartsand
thePollenLamp(Green)lights
up.
OPERATIONPANEL
REMOTECONTROL
Ion
+
Auto
Ion
+
Quiet
Ion
+
Standard
Ion
+
High
Ion
+
Rapid
NAMEOFCOMPONENTPARTS
RemoteControlReceptor
FanSpeed
Lamps
Auto
Quiet
Standard
High
Rapid
Dust
Lamp
Timer
Lamp
FilterLife
Lamp
Odour
Lamp
English
ETK-S50 (GB) 10.6.22 9:03 AM ページ 7

8
PREPARATIONBEFOREUSE
1
HOWTOINSTALLTHEFILTERS(BesuretoassembleFiltersbeforeusingtheAirPurifier.)
1
1Pull the front panel toward you and remove it while
pressingtherightandleftbuttonsatthebottomofthe
mainunit.
2
2RemovethePrefilter.
3
3RemovetheenzymeHEPAfilterandactivecharcoal
filterinthebagfromthemainunit.
4
4TaketheenzymeHEPAfilterandactivecharcoalfilter
outofthebagandputthethinneractivecharcoalfilter
behind the enzyme HEPA filter, then mount the
enzymeHEPAfiltertothemainunitaccordingtothe
mountingdirection↑withthegreen-clothsidetothe
front.MountthePrefilter,too.
5
5Alignthenailslocatedatthetopofthefrontpanelto
themainunit,andhangthefrontpanelontotheright
andlefthooksatthelowerpart.
★IftheenzymeHEPAfilterandactivecharcoalfilteraremountedincorrectly,thefilterswill
notworkproperly.Makesurethatthegreen-clothsideoftheenzymeHEPAfilterisinfront.
★Dirty enzyme HEPA filters and active charcoal filters cannot be reused even if they are
washed.Besuretoreplacethem.
★The enzyme HEPA filters should be replaced about five years after opening the package.
Theactivecharcoal filtersshouldbereplacedabouttwo yearsafteropeningthepackage.
Thereplacementfrequencydependsonhowlongtheyareusedorwheretheyareinstalled.
● The lifetime of the filters will become very short in cases where they absorb oily smoke or
carbonizedsubstancessuchassoot.
NOTE
Button
Prefilter
Hook
ETK-S50 (GB) 10.6.22 9:03 AM ページ 8

9
●HowtoeffectivelyinstalltheAirPurifier
Install the Air Purifier in a high place (on a table) when cleaning relatively small-sized dust such as
Heavy smoke. Install the unit in a low place (on the floor) when cleaning large-sized dust such as
pollen.
●Wheninstallingitonthefloororonatable
Placeitonthefloorortableapproximately30cmawayfromthe
surroundingwalls.
Opentherearcoverforbatteriesbyslidingitdownandplacethem
inposition.Donotplacethebatteriestothewrongpoles(+and
-
).
2
HOWTOINSTALLAIRPURIFIER(Chooseaplacewhereindooraircirculateswell.)
3
HOWTOINSERTBATTERIESINTOTHEREMOTECONTROL
●TheRemoteControlistobecarefullyused.IftheRemoteControlisdroppedtotheflooror
spilledwithwater,itmaynotbeabletotransmitthesignaltotheAirPurifier.
●Themaximumsignalrangeisabout7m(front).
●IftheRemoteControloperationdoesnotactuatetheAirPurifier,replacebothtwobatteries
(R03)D3 with the newones. If theoperationof the AirPurifier is still notnormal, remove
batteriesand,afteranelapseofmorethan5seconds,returnthemintotheRemoteControl.
●Theestimatedlifeofthebatteryisapproximatelyoneyear,ifusedwiththenormalcondition,
providedthatthebatteryofwhichserviceperiodiscloseto"recommendedusingperiod"
willhavetobereplacedshortly.
●The use of the wrong batteries may cause such dangers as liquid leakage and collapse.
Carefullyreadtheprecautionsprovidedonthebatteryandtakespecialcareofthefollowing
pointsforuse.
● Careistobetakennottomixoldandnewbatteriesnortousethewrongkinds.
● IftheRemoteControlisnotusedforlongtime(morethanonemonth),removethebatteriesfrom
it. Should any liquid leakage be caused, remove the leakage completely and replace with the
newbatteries.
NOTE
PREPARATIONBEFOREUSE
Rear
Cover
English
ETK-S50 (GB) 10.6.22 9:03 AM ページ 9

10
①Presstheoperationbutton
● TheAirPurifierOperationstarts.
● Eachpressoftheoperationbuttonswitchestheoperationmodeinthefollowingorder.Selectdesired
operationmode.
● TheAutolampindicatesautomaticoperation.
● TheFanSpeedlampindicatesthechangingofthefanspeed.
Ion
+
Auto
Ion
+
Quiet
Ion
+
Standard
Ion
+
High
Ion
+
Rapid
Stop
OPERATIONBYOPERATIONPANEL
OPERATIONPROCEDURE
1
ON/OFFAUTOMATICOPERATIONCHANGINGTHEFANOPERATIONMODE
★Timer operation, Smoking operation and Pollen operation cannot be made by operation
paneloftheMainUnit.UseRemoteControl.
NOTE
①
Operation
Button
Auto
Quiet
Standard
High
Rapid
TimerLamp
FilterLifeLamp
OdourLamp
DustLamp
FanSpeedLamps
ETK-S50 (GB) 10.6.22 9:03 AM ページ 10

11
● DuringAutomaticoperationtheAUTOLamp(Green)lightstogetherwitharedlampindicatingthefan
speed.
■Lightingoftheairmonitorlampintheautomaticoperationmode.
● The air monitor lamp will not light for three minutes after plugging in the power cord. (The three
minutesarerequiredfor preliminary operation ofthesensor.)Automaticoperation means standard
operationwhentheairmonitorisnotlightingup.
● Whenairisdirty,theairmonitorlampturnsRed.
● TheoperationmodewillchangeaccordingtohowmanytimestheairmonitorlampturnsRed.
■Theoperationmodewillbeswitchedaccordingtohowmanytimestheredlamphasbeenlit(the
moreredlamps,thedirtier).
Airmonitor
Operationmode
Ion
+
Auto
Ion
+
Quiet
Ion
+
Standard
Ion
+
High
Ion
+
Rapid
AUTOMATICOPERATION
OPERATIONPROCEDURE
English
ETK-S50 (GB) 10.6.22 9:03 AM ページ 11

12
OPERATIONBYREMOTECONTROL
HOWTOUSETHEREMOTECONTROL
● OperatetheRemoteControlbypointingfowardsthemainunit(receiver).
● Themaximumsignalrangeisabout7m(front).
● Makesurenoobjectobstructsthesignal.
①PresstheON/OFFbutton.
● TheAirPurifierstarts.
● Pressthebuttononemoretimetostoptheoperation.
②PresstheFanSpeedbutton.
● Eachpressoftheoperationbuttonchangestheoperationmodeinthefollowingorder.Selectdesired
operationmode.
● TheAutolamp(Green)indicatesau-
tomaticoperation.
● The Fan Speed lamp (Red)indi-
catesthechanging.
Ion
+
Auto
Ion
+
Quiet
Ion
+
Standar
Ion
+
High
Ion
+
Rapid
Stop
ON/OFFAUTOMATICOPERATIONCHANGINGTHEOPERATIONMODE
1
OPERATIONPROCEDURE
RemoteControlReceptor
Dust
Lamp
Odour
Lamp
Filter Life
Lamp
Timer
Lamp
②
①
FanSpeedLamps
Auto
Quiet
Standard
High
Rapid
ETK-S50 (GB) 10.6.22 9:03 AM ページ 12

13
①Pressthe"TIMER"buttonwhileinoperation.
● The setting time changes in the following modes as the button is pressed each time. Set at your
desirabletimemode.
● SettingtimeisindicatedbyTimerlamp(Green).
(Automaticoperationisstoppedaftersettime.)
②TostopTimeroperation,presstheON/OFFbutton.
2TIMEROPERATION
OPERATIONPROCEDURE
TimerLamp
RemoteControlReceptor
Dust
Lamp
Odour
Lamp
FilterLife
Lamp
Timer
Lamp
①
②
FanSpeedLamps
Auto
Quiet
Standard
High
Rapid
TimerSetting
TimeMode
TheTimer
operationwillbe
stoppedafter
onehour.
TheTimer
operationwillbe
stoppedafter
twohours.
TheTimer
operationwillbe
stoppedafter
fourhours.
TheTimeroperation
iscancelled.
NoTimeroperation
isnotgiven.
()
English
ETK-S50 (GB) 10.6.22 9:03 AM ページ 13

14
①PresstheSmokingbutton.
●
TheSmokinglamp(Green)willlightup.
●
Smoking Operation starts and the air
blower speed changes automatically as
shown below, then the mode will switch
toautomaticoperation.
②Tostopthesmokingoperation,press
theON/OFFbuttononemoretime.
★
When the Smoking button is pressed
during operation or halts, the Smoking
Operationmodewillstart.
★
WhentheSmokingbuttonispressedduring
Pollen Operation, the Pollen Operation will
be cancelled and the Smoking Operation
starts, lasting for 10 minutes, then it
changestoautomaticoperation.
10min.
Ion
+
Rapid
Pressthe
Smoking
Button
Ion
+
Auto
3SMOKINGOPERATION
Whenyoufrequentlysmoke,ormanypeoplesmoke,theRapidoperationortheHighoperationarerecommended.
ADVICE
OPERATIONPROCEDURE
Ion+Rapid(10min.)Ion+Auto
Whileinstop
Rapidoperation
Highoperation
Standardoperation
Quietoperation
Timeroperation
Pollenoperation
SmokingLamp
RemoteControlReceptor
Dust
Lamp
Odour
Lamp
FilterLife
Lamp
Timer
Lamp
FanSpeedLamps
Auto
Quiet
Standard
High
Rapid
①
②
ETK-S50 (GB) 10.6.22 9:03 AM ページ 14

15
①PressthePollenbutton.
● ThePollenlamp(Green)willlightup.
●
BypressingPollenbutton,Pollenoperationstarts.
Thefanspeedwillnextbechangedautomatically
torepeattheoperationinthefollowingsequence.
Ion+Standard
(10min.)
Ion+Quiet
(10min.)
Repeatthreetimes
Ion
+
Auto
②TostopthePollenoperation,presstheON/OFFbuttononemoretime.
★Press the Pollen button during operation or halts to start the Pollen Operation and the air blower
speedwillbeautomaticallychanged.
★IfthePollenbuttonispressedduringTimerOperation,thePollenOperationwillstartbuttheturn-off
timesettingremainseffective.
★IfthePollenbuttonispressed,theSmokingOperationwillbecancelledandthemodewillchangeto
PollenOperation.
(10min.)
Ion+
Standard
Press
the
Pollen
Button
(10min.)
Ion+
Quiet
Ion
+
Auto
Repeatthreetimes
4POLLENOPERATION
OPERATIONPROCEDURE
Smokingoperation
Timeroperation
Quietoperation
Standardoperation
Highoperation
Rapidoperation
Whileinstop
RemoteControlReceptor
Dust
Lamp
Odour
Lamp
FilterLife
Lamp
Timer
Lamp
PollenLamp
FanSpeedLamps
Auto
Quiet
Standard
High
Rapid
②
①
English
ETK-S50 (GB) 10.6.22 9:03 AM ページ 15

16
ROUTINEMAINTENANCE
●Whencleaningthemainunit,wipeitwithasoftclothsoakedindishwashingdetergentanddry
withasoftcloth.
★Do not use paint thinner, benzene or alcohol to avoid the degradation or discoloration of the body.
WipingtheunitwithbenzenorpaintthinnermayresuitinCrackingorElectricalShock.
WARNING
★Only authorized technicians should disassemble, repair, or
modifythisproduct.
● Ignitionormalfunctionmayoccur,causinginjury.
★Be sure to remove the power plug from the electrical outlet
when performing maintenance. Do not remove or insert the
plugwithwethands.
● Failuretoheedthiswarningmayresultinelectricshockorburns.
CAUTION
★CleanthePrefilterperiodically(morethanonceeverytwoweeks).
● IfthePrefilteriscontinuouslyusedandanexcessiveamountofcottonwaste,
accumulates,theAirPurifiermaybesubjectedtoinflammationormalfunction.
BesurealsotoalwaysusethePrefilterforAirPurifieroperation.
First stop the operation of the Air Purifier and next
removethepowerplugfromtheelectricaloutlet.
Pullthefrontpaneltowardyouandremoveitwhilepressingtherightandleftbuttonsatthe
bottomofthemainunit.
RemovethePrefilter.
Button
1
11
1
2
2
3
3
2
23
3Prefilter
ETK-S50 (GB) 10.6.22 9:03 AM ページ 16

17
ROUTINEMAINTENANCE
CleanthePrefilterwithelectricvacuumcleaner.
★When it is contaminated excessively, wash with lukewarm water or water mixed with neutral
detergentanddrycompletelyintheshade.
ReturnthePrefiltertotheFrontPanel.
★ThePrefilterhasnorightsideup.
Alignthenailslocatedatthetopofthefrontpaneltothemainunit,andhangthefrontpanel
ontotherightandlefthooksatthelowerpart.
MAINTENANCEOFHEPAFILTER(LIGHTINGOFFILTERLAMP)
●WhentheenzymeHEPAfilterisdirty,thefilterlampwilllight.Ifitlights,pleaserefertothe
1HOWTOINSTALLTHEFILTERSandreplacetheoldanddirtyHEPAfilterwithanewone,which
isoptionallyavailable.
●Be sure to press the Reset Button after replacing the enzyme HEPA filter and completing its
installation.Otherwise,thefilterlampwillremainONand the following filter replacement time
willnotbeindicated.
※Activecharcoalfiltersshouldbereplacedeverytwoyearsorso.Pleasereplacewithanewonewhen
theoldonedeterioratesandisunabletoeliminateodors.
<Whenthefrontpanelisremoved,theresetswitchisaccessible.>
Hook
6
6
5
5
4
4
6
6
5
5
4
4
LIGHTINGOFFILTERLAMP
ResetButtonOdorSensor
FilterLamp
English
ETK-S50 (GB) 10.6.22 9:03 AM ページ 17

18
ACPLUGANDOUTLET
●DustanddirtontheACplugandtheelectricoutletcancauseafire.Unplugtheappliancemorethan
onceeverythreemonthsandremovedustanddirt.
ROUTINEMAINTENANCE
Standard operation
(High operation)
Filter Life Lamp
0~3650h
(0~2500h)
3651~7300h
(2501~5000h)
7301~10950h
(5001~7500h)
10951~14600h
(7501~10000h)
( )
more than 14600h
(10000h)
Filter lamp
will light.
ETK-S50 (GB) 10.6.22 9:03 AM ページ 18
Other manuals for ETK-S50