TROUBLESHOOTING GUIDE
INDICATION LAMP
ALARM
INDICATION TIME APPEARANCE, PORTION, PARTS
SEEMED WRONG
MOMENTARY STOP OF POWER
(IN CASE OF LIGHTNING)
DROP OF POWER VOLTAGE
check the the power voltage(230v) and the wiring connection
emergency operation (display of remote controller is faint or not)
check the electric continuity by tester
check the electric continuity by tester
emergency operation
other than described above
15 sec. later after main power on, if alarm indication appears, TAN
PCB (main) should be replaced
check the other indoor unit operation mode.
when operating each indoor units, make sure that they are in the
same operation mode. (Cooling/ Dry or Heating)
METHOD OF CHECK
(press the ON/OFF button of remote controller in case of reset)
POWER
(green) TIMER
(yellow)
OPERATION
(green)
INDICATION LAMP
OFF OFF OFF
TAN, TAG not work at all
FLASHING
OFF OFF
FLASHING
ON ON
ON
ON ON
FLASHING
FLASHING
ON OFF
OFF
alarm indication appears
immediately when press
the operation switch
OFF OFF
FLASHING
OFF
FLASHING
FLASHING
OFF
FLASHING
TAN, TAG don’t work
at all, and after 40 sec.,
operation lamp is flashing
(2 min. in case of power on)
normal lamp indication
turn alarm when something is
wrong with
TAN, TAG
error of transmission
CT disconnection
OFF
FLASHING
OFF
FLASHING FLASHING
OFF
OFF
OFF
30 〜40 min. later after
compressor start, the yellow
lamp is flashing and TAN,
TAG stop running
sensor discharge operate
because temperature of
discharge tube beyond
100°C, or sensor
discharge is bad quality
protective action against
excess current AC current
detection
FLASHING FLASHING
ON
FLASHING
FLASHING
FLASHING
ON
FLASHING
FLASHING
once or two times stop
running with power lamp
lighting when something
is wrong with TAN, TAG,
later after that in case of
reoccurrence, alarm
indication appears.
protective action against
excess current DC current
detection
rise of temperature
(above 100°C) of power
module
in case of heating
operation, a rise of
temperature (above 62°C)
of TAN heat exchanger
or less quantity of TAN
blow
FLASHING FLASHING
FLASHING
ON
FLASHING
in case of heating operation,
after a few minutes operation,
all lamps are flashing and
TAN, TAG stop running
accident of controller
fifth beep and TAN, TAG
don't work at all.
short or open of sensor,
temperature or incomplete
insertion of connector
TAN PCB (MAIN)
TAG PCB (MAIN)
SENSOR, TEMP. ROOM
SENSOR, TEMP. HEAT EXCHANGER
SENSOR, TEMP. DEFROST
SENSOR, TEMP. DISCHARGE
SENSOR, TEMP. OUTDOOR
FILTER IS CHOKED
SENSOR, TEMP. HEAT EXCHANGER
TAN PCB (MAIN)
FAN MOTOR (TAN)
UNREASONABLE OPERATION
UNDER OVERLOAD
MOMENTARY STOP OF POWER
(IN CASE OF LIGHTNING)
DROP OF POWER VOLTAGE
TAG PCB (MAIN)
COMPRESSOR LOCKING
POWER SUPPLY
REMOTE CONTROL
TAN FUSE(3.15A)
TAN TERMINAL BLOCK
PCB (RECEIVER & DISPLAY)
TAN PCB ( MAIN)
MIS-WIRING
(TAG-TAN CONNECTING CABLE)
OR RARE CONTACT
CUTTING OFF CT
CURRENT FUSE . (15A) FUSING
(ON THE TAG PCB(FILTER))
UNREASONABLE OPERATION
UNDER OVERLOAD
GAS LEAKAGE
VALVE, SERVICE IS CLOSED
PIPE
SENSOR, TEMP. DISCHARGE
check the place of installation (blockage of air inlet & outlet of TAN, TAG)
check the excessive gas
check the movement by reoperation
check the power voltage (230V)
check the place of installation (blockage of air inlet & outlet of
TAN, TAG)
check by eyes and clean it
check the resistance by tester [see table 2]
check the voltage between blue and yellow in connector [see fig. 2]
if it is not AC 110V〜230V, TAN PCB (main) should be replaced
other than described above
check the movement by reoperation
check the power voltage (230V)
If the same alarm lamp will remain lit during operation even after
disconnecting the connector of the lead cable to the compressor,
it implies the defect of the TAG controller assy.
If the same alarm lamp wil remain lit duning operation even after
replacing
the TAG controller assy, it implies the defect of the compressor.
change the TAG controller assy
check the place of installation (blockage of air inlet & outlet of TAN, TAG)
check the excessive gas
check the wiring connection and rare contact
check the resistance by tester [see table 1]
check the resistance by tester [see table 2]
check the resistance by tester [see table 2]
check the resistance by tester [see table 3]
check the resistance by tester [see table 2]
check the resistance by tester [see table 4]
check the resistance by tester [see table 4]
check the point of leakage (discharge temperature rise in case of
small leakage), measure the pressure of compressor during fixed
operation (emergency and test operation)
check the valve by eyes
check by eyes
check the resistance by tester [see table 3]
check the voltage.[see fig. 1]
(if it is no continuity, TAG controller assy should be replaced.)
ON
FLASHING
ON
ON
later after start running through remote controller, if alarm
indication appears, TAG controller assy should be replaced
--
SENSOR, TEMP. LIQUID PIPE
DIFFERENT OPERATION
SENSOR, TEMP. GAS PIPE
SHORT CYCLE
(INSUFFICIENT AIR CIRCULATION)
UNREASONABLE OPERATION
UNDER OVERLOAD
--- -
-
abnormal revolution of
compressor
UNREASONABLE OPERATION
UNDER OVERLOAD
MOMENTARY STOP OF POWER
(IN CASE OF LIGHTNING)
DROP OF POWER VOLTAGE
TAG PCB (MAIN)
COMPRESSOR LOCKING
check the place of installation (blockage of air inlet & outlet of TAN, TAG)
check the excessive gas
check the movement by reoperation
check the power voltage (230V)
If the same alarm lamp wil remain lit duning operation even after
replacing
the TAG controller assy, it implies the defect of the compressor.
Micro computer self-diagnose the points of the troubles and inform it by the combination of the status (On, Flush, or
Off) of three lamp indicators on the front panel of the indoor unit.