
1 Safety.................................................................. 6
1.1 General safety notes................................... 6
1.2 Correct use.................................................. 6
1.3 Qualified staff............................................... 6
2 Technical data.................................................... 7
2.1 General data................................................ 7
2.2 FKA2-EU with fusible link............................ 8
2.3 FKA2-EU with spring return actuator......... 11
2.4 FKA2-EU with spring return actuator and
duct smoke detector.................................. 18
3 Transport and storage..................................... 19
4 Parts and function........................................... 20
4.1 FKA2-EU with fusible link.......................... 20
4.2 FKA2-EU with spring return actuator......... 20
4.3 FKA2-EU with spring return actuator and
duct smoke detector.................................. 21
5 Installation........................................................ 22
5.1 Installation situations................................. 22
5.2 Safety notes regarding installation............ 24
5.3 General installation information................. 24
5.3.1 Installation kit supply package and
assembly ES.......................................... 33
5.4 Solid walls................................................. 35
5.4.1 Mortar-based installation........................ 36
5.4.2 Mortar-based installation with partial
mortaring................................................ 38
5.4.3 Dry mortarless installation with installa-
tion kit ES............................................... 39
5.4.4 Dry mortarless installation with fire batt.. 43
5.5 Solid ceiling slabs...................................... 44
5.5.1 Mortar-based installation into solid
ceiling slabs............................................ 45
5.5.2 Mortar-based installation into a concrete
base........................................................ 48
5.5.3 Mortar-based installation in conjunction
with wooden beam ceilings.................... 49
5.5.4 Mortar-based installation in conjunction
with solid wood ceilings.......................... 50
5.5.5 Dry mortarless installation with installa-
tion kit ES............................................... 51
5.6 Lightweight partition walls and compart-
ment walls with metal support structure.... 53
5.6.1 Mortar-based installation........................ 57
5.6.2 Dry mortarless installation with installa-
tion kit ES............................................... 62
5.6.3 Dry mortarless installation with installa-
tion kit ES remote from a lightweight
partition wall........................................... 66
5.6.4 Dry mortarless installation with fire batt.. 68
5.7 Lightweight partition walls with timber sup-
port structure............................................. 71
5.7.1 Mortar-based installation........................ 73
5.7.2 Dry mortarless installation with installa-
tion kit ES............................................... 76
5.7.3 Dry mortarless installation with fire batt.. 78
5.8 Solid wood walls........................................ 80
5.8.1 Mortar-based installation........................ 81
5.8.2 Dry mortarless installation with installa-
tion kit ES............................................... 82
5.8.3 Dry mortarless installation with fire batt.. 83
5.9 Shaft walls with metal support structure.... 84
5.9.1 Mortar-based installation........................ 86
5.9.2 Dry mortarless installation with installa-
tion kit ES............................................... 89
5.10 Fixing the fire damper.............................. 90
5.10.1 General................................................. 90
5.10.2 Suspending fire dampers installed
remote from solid walls and ceiling
slabs..................................................... 91
5.10.3 Fixing the damper when a fire batt is
used...................................................... 92
6 Accessories..................................................... 93
7 Electrical connection...................................... 96
7.1 Limit switches (fire dampers with fusible
link)............................................................ 96
7.2 Spring return actuator................................ 96
7.3 Spring return actuator and duct smoke
detector RM-O-3-D.................................... 96
8 Functional test................................................. 97
8.1 Fire damper with fusible link...................... 97
8.1.1 Fusible link – size 1................................ 97
8.1.2 Fusible link – size 2 and 3...................... 98
8.2 Fire damper with spring return actuator.. 101
8.2.1 Spring return actuator – BFL... / BFN... 101
8.2.2 Spring return actuator – BF.................. 103
8.3 Functional test with automatic control
unit........................................................... 105
9 Commissioning.............................................. 106
10 Maintenance................................................... 107
10.1 General.................................................. 107
10.2 Replacing the fusible link....................... 108
10.2.1 Fusible link – size 1............................ 108
10.2.2 Fusible link – size 2 and 3.................. 109
10.3 Inspection, maintenance and repair
measures............................................... 110
11 Decommissioning, removal and disposal... 112
12 Legend............................................................ 113
13 Index............................................................... 117
Table of contents
Fire damper Type FKA2-EU 5