1 Safety ................................................................ 7
1.1 General safety notes ................................. 7
1.2 Correct use ................................................ 7
1.3 Qualified staff ............................................. 8
2 Technical data .................................................. 9
2.1 General data .............................................. 9
2.2 FK2-EU with fusible link ........................... 11
2.3 FK2-EU with spring return actuator ......... 14
2.4 FK2-EU with spring return actuator and
duct smoke detector ................................ 21
2.5 FK2-EU with fusible link and cover grille
used as an air transfer unit ...................... 22
2.6 FK2-EU with spring return actuator and
duct smoke detector used as an air
transfer damper ....................................... 23
3 Supply package, transport and storage ...... 24
4 Parts and function ......................................... 25
4.1 FK2-EU with fusible link .......................... 25
4.2 FK2-EU with spring return actuator ......... 25
4.3 FK2-EU with spring return actuator and
duct smoke detector ................................ 26
4.4 FK2-EU with fusible link and cover grille
used as an air transfer unit ...................... 26
4.5 FK2-EU with spring return actuator and
duct smoke detector used as an air
transfer damper ....................................... 27
5 Installation ...................................................... 28
5.1 Installation situations ............................... 28
5.2 Safety notes regarding installation .......... 33
5.3 General installation information ............... 33
5.3.1 Installation kit supply package and
assembly ES ........................................ 45
5.3.2 Installation kit supply package and
assembly WA / WE ............................... 47
5.3.3 Installation kit supply package and
assembly GL ........................................ 50
5.4 Solid walls ............................................... 52
5.4.1 Mortar-based installation ...................... 53
5.4.2 Mortar-based installation – multiple
occupancy of an installation opening ... 57
5.4.3 Mortar-based installation – 4-way
arrangement with common duct ........... 59
5.4.4 Mortar-based installation with partial
mortaring .............................................. 62
5.4.5 Mortar-based installation with flexible
ceiling joint ............................................ 63
5.4.6 Dry mortarless installation on a solid
wall with installation kit WA ................... 66
5.4.7 Dry mortarless installation remote from
solid walls with installation kit WE ........ 67
5.4.8 Dry mortarless installation with fire batt
............................................................... 71
5.5 Lightweight partition walls and compart-
ment walls with metal support structure .. 73
5.5.1 Mortar-based installation ...................... 77
5.5.2 Mortar-based installation – multiple
occupancy of an installation opening ... 83
5.5.3 Mortar-based installation – 4-way
arrangement with common duct ........... 85
5.5.4 Dry mortarless installation with installa-
tion kit ES ............................................. 88
5.5.5 Dry mortarless installation with mineral
wool ...................................................... 91
5.5.6 Dry mortarless installation with plaster-
board cladding/fire-rated plasterboard
panels ................................................... 92
5.5.7 Dry mortarless installation with flexible
ceiling joint and installation kit GL100 .. 93
5.5.8 Dry mortarless installation remote from a
lightweight partition wall with installation
kit WE ................................................... 98
5.5.9 Dry mortarless installation with fire batt
............................................................ 100
5.6 Lightweight partition walls with timber sup-
port structure ......................................... 104
5.6.1 Mortar-based installation .................... 106
5.6.2 Mortar-based installation – multiple
occupancy of an installation opening .. 110
5.6.3 Mortar-based installation – 4-way
arrangement with common duct ......... 113
5.6.4 Dry mortarless installation with installa-
tion kit ES ............................................ 116
5.6.5 Dry mortarless installation with mineral
wool .................................................... 118
5.6.6 Dry mortarless installation with fire batt
............................................................ 120
5.7 Solid wood walls .................................... 126
5.7.1 Mortar-based installation .................... 127
5.7.2 Dry mortarless installation with installa-
tion kit ES ........................................... 128
5.7.3 Dry mortarless installation with mineral
wool .................................................... 129
5.7.4 Dry mortarless installation with fire batt
............................................................ 130
5.8 Shaft walls with metal support structure 131
5.8.1 Mortar-based installation .................... 133
5.8.2 Dry mortarless installation with installa-
tion kit ES ........................................... 138
5.9 Shaft walls without metal support structure
................................................................ 140
5.9.1 Dry mortarless installation with installa-
tion kit ES ........................................... 142
5.10 Solid ceiling slabs ................................ 143
5.10.1 Mortar-based installation into solid
ceiling slabs ...................................... 144
5.10.2 Mortar-based installation into a con-
crete base ......................................... 150