Capacitive sensor
BC3-M12-AP6X/S90/3GD 15M
Edition • 2017-06-25T02:09:33+02:00
1 / 4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Type designation BC3-M12-AP6X/S90/3GD 15M
Ident no. 2601004
Rated switching distance (flush) 3 mm
Rated switching distance (non-flush) 3 mm
Secured operating distance ð (0.72 x Sn) mm
Hysteresis 2…20 %
Temperature drift type 20 %
Repeat accuracy ð 2 % of full scale
Ambient temperature -25…+70 °C
For explosion hazardous areas see instruction
leaflet
Operating voltage 10…30 VDC
Residual ripple ð 10 % Uss
DC rated operational current ð 200 mA
No-load current I0ð 15 mA
Residual current ð 0.1 mA
Switching frequency 0.1 kHz
Isolation test voltage ð 0.5 kV
Output function 3-wire, NO contact, PNP
Short-circuit protection yes/ Cyclic
Voltage drop at Ieð 1.8 V
Wire breakage/Reverse polarity protection yes/ Complete
Approval acc. to ATEX declaration of conformity TURCK Ex-03025H
X
Device marking Ex II 3 G Ex nA IIC T5 Gc / II 3 D Ex t IIIC T91°C Dc
Warning Protect against mechanical damage
Design Threaded barrel, M12 × 1
Dimensions 63.5 mm
Housing material Metal, CuZn, Chrome-plated
Active area material Plastic, ABS, yellow
Admissible pressure on front cap ð 5 bar
Max. tightening torque housing nut 10 Nm
Electrical connection Cable
Cable quality Ø 4, LifYY-11Y, PUR, 15m
Cable cross section 3 x 0.25 mm2
Vibration resistance 55 Hz (1 mm)
Shock resistance 30 g (11 ms)
Protection class IP67
MTTF 1080 years acc. to SN 29500 (Ed. 99) 40 °C
Switching state LED yellow
■ATEX category II 3 G, Ex zone 2
■ATEX category II 3 D, Ex zone 22
■M12 × 1 threaded barrel
■Chrome-plated brass
■Fine adjustment via potentiometer
■DC 3-wire, 10…30 VDC
■NO contact, PNP output
■Cable connection
Wiring Diagram
Functional principle
Capacitive proximity switches are designed
for non-contact and wear-free detection of
electrically conductive as well as non-conduc-
tive metal objects.
Capacitive sensor
BC3-M12-AP6X/S90/3GD 15M
Edition • 2017-06-25T02:09:33+02:00
2 / 4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Mounting instructions/Description minimum distances
Distance D 24 mm
Distance W 9 mm
Distance S 18 mm
Distance G 18 mm
Diameter active area B Ø 12 mm
The given minimum distances have been checked
against the standard switching distance.
Should the sensitivity of the sensors be changed via
potentiometer, the data sheet specifications no longer
apply.
Capacitive sensor
BC3-M12-AP6X/S90/3GD 15M
Edition • 2017-06-25T02:09:33+02:00
3 / 4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Accessories
Type code Ident no. Description
MAP-M12-PP 6950016 Mounting adapter; material: Polypropylene; sensor replace-
ment with filled container possible (adapter remains in con-
tainer during sensor replacement)
MAP-M12-PVDF 6950017 Mounting adapter; material: Polyvenylidenflourid; sensor can
be replaced with filled container (adapter remains in contain-
er during replacement)
BST-12B 6947212 Fixing clamp for threaded barrel devices, with dead-stop; ma-
terial: PA6
Capacitive sensor
BC3-M12-AP6X/S90/3GD 15M
Edition • 2017-06-25T02:09:33+02:00
4 / 4 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Operating manual
Intended use
This device fulfills the directive 2014/34/EC and is suited for use in explosion hazardous areas acc. to EN60079-0:2009, EN60079-15:2010 and
EN60079-31:2009.
In order to ensure correct operation to the intended purpose it is required to observe the national regulations and directives.
For use in explosion hazardous areas conform to classification
II 3 G and II 3 D (Group II, Category 3 G, electrical equipment for gaseous atmospheres and category 3 D, electrical equipment for dust atmo-
spheres).
Marking (see device or technical data sheet)
Ex II 3 G and Ex nA IIC T5 Gc acc. to EN 60079-0:2009 and EN 60079-15:2010 and Ex II 3 D Ex t IIIC T91°C Dc acc. to EN 60079-0:2009 and
EN 60079-31:2009
Installation / Commissioning
These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection
classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas.
Please verify that the classification and the marking on the device comply with the actual application conditions.
Installation and mounting instructions
Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and
avoid build-up of dust deposits on the device.
If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against
strong electro-magnetic fields.
The pin configuration and the electrical specifications can be taken from the device marking or the technical data sheet.
In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before in-
serting the cable or opening the cable socket.
Special conditions for safe operation
Devices with terminal chamber (cable glands) have a weaker strain relief. Sufficient strain relief must be ensured or the cable must be station-
ary-mounted.
Do not disconnect the plug-in connection or cable under voltage.
Please attach a warning label permanently in an appropriate fashion in close proximity to the plug-in connection with the following inscription:
Nicht unter Spannung trennen / Do not separate when energized.
The device must be protected against any kind of mechanical damage and degrading UV-radiation. On selecting the approval-relevant acces-
sories, always ensure that they are installed conform to the application.
Load voltage and operating voltage of this equipment must be supplied from power supplies with safe isolation (IEC 30 364/UL508), to ensure
that the rated voltage of the equipment (24 VDC +20% = 28.8 VDC) is never exceeded by more than 40%.
service / maintenance
Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important
data from the approval are listed.

This manual suits for next models

3

Other turck Accessories manuals

turck RU100-CP40 Series User manual

turck

turck RU100-CP40 Series User manual

turck FCS-G1/4A4-NAEX0 User manual

turck

turck FCS-G1/4A4-NAEX0 User manual

turck RU D UPN8X2 Series User manual

turck

turck RU D UPN8X2 Series User manual

turck FCS-G1/2HC4-NAEX/L065/D100 User manual

turck

turck FCS-G1/2HC4-NAEX/L065/D100 User manual

turck FS100 L Series User manual

turck

turck FS100 L Series User manual

turck High-End Series User manual

turck

turck High-End Series User manual

turck PS Series User manual

turck

turck PS Series User manual

turck FTCI Series User manual

turck

turck FTCI Series User manual

turck S1102 User manual

turck

turck S1102 User manual

turck NIMFE-EM12/4,9L88-UP6X-H1141/S1182 User manual

turck

turck NIMFE-EM12/4,9L88-UP6X-H1141/S1182 User manual

turck RU600U Series User manual

turck

turck RU600U Series User manual

turck RU40U-M18MS-AP8X2-H1151 User manual

turck

turck RU40U-M18MS-AP8X2-H1151 User manual

turck Ri360P1-DSU35TC-ELi-Exi User manual

turck

turck Ri360P1-DSU35TC-ELi-Exi User manual

turck CMTH Series User manual

turck

turck CMTH Series User manual

turck RU40U/3GD Series User manual

turck

turck RU40U/3GD Series User manual

turck LTX-R10 Series User manual

turck

turck LTX-R10 Series User manual

turck RU U-M AP8X User manual

turck

turck RU U-M AP8X User manual

turck NI4-DSU35-2Y1X2-H1140 User manual

turck

turck NI4-DSU35-2Y1X2-H1140 User manual

turck LPRE-M30-AP6X2-H1141 User manual

turck

turck LPRE-M30-AP6X2-H1141 User manual

turck FCS-GL1/2TN-NAEX-H1141 User manual

turck

turck FCS-GL1/2TN-NAEX-H1141 User manual

turck LTX Series User manual

turck

turck LTX Series User manual

turck FCS-G1/4A4-NAEX0-H1141 User manual

turck

turck FCS-G1/4A4-NAEX0-H1141 User manual

turck FCS-G NAEX Series User manual

turck

turck FCS-G NAEX Series User manual

turck PS310 Series User manual

turck

turck PS310 Series User manual

Popular Accessories manuals by other brands

Hioth CT-SMEA2004-PT user manual

Hioth

Hioth CT-SMEA2004-PT user manual

Vega PLICSMOBILE T81 operating instructions

Vega

Vega PLICSMOBILE T81 operating instructions

GSN PATROL 501 Installation instructions manual

GSN

GSN PATROL 501 Installation instructions manual

Multilaser CB066 user manual

Multilaser

Multilaser CB066 user manual

MAC PARA Haven user manual

MAC PARA

MAC PARA Haven user manual

Asus ESC4000 G2 GPU quick start guide

Asus

Asus ESC4000 G2 GPU quick start guide

Air Naturel Saho user manual

Air Naturel

Air Naturel Saho user manual

IFM Electronic PY2954 Operating	 instruction

IFM Electronic

IFM Electronic PY2954 Operating instruction

MECNOSUD SB Series Use and maintenance manual

MECNOSUD

MECNOSUD SB Series Use and maintenance manual

SkyBound TRAMPOLINE MAT installation manual

SkyBound

SkyBound TRAMPOLINE MAT installation manual

Emmaljunga NXT Curb Lifter instruction manual

Emmaljunga

Emmaljunga NXT Curb Lifter instruction manual

aci HAZARDOUS ROOM Series Installation & operation instructions

aci

aci HAZARDOUS ROOM Series Installation & operation instructions

Goobay 60656 user manual

Goobay

Goobay 60656 user manual

Alpha Comm Enterprises POWER FUEL user manual

Alpha Comm Enterprises

Alpha Comm Enterprises POWER FUEL user manual

Turner Designs C-FLUOR user manual

Turner Designs

Turner Designs C-FLUOR user manual

Delta Kitchen KS 100 instruction manual

Delta Kitchen

Delta Kitchen KS 100 instruction manual

ITOH DENKI POWER MOLLER PLUS F-RAT-NX75 manual

ITOH DENKI

ITOH DENKI POWER MOLLER PLUS F-RAT-NX75 manual

Gin Yeti Xtrem 2 user manual

Gin

Gin Yeti Xtrem 2 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.