turck FCS-G1/2A4-NAEX0-H1141/L065 User manual

Flow monitoring
Immersion sensor without integrated processor
FCS-G1/2A4-NAEX0-H1141/L065
Edition • 2016-06-25T23:45:41+02:00
1 / 2 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Type code FCS-G1/2A4-NAEX0-H1141/L065
Ident no. 6870375
Mounting conditions insertion style sensor
Water Operating Range 1…100cm/s
Oil Operating Range 3…200 cm/s
Stand-by time typ. 8 s (2…18 s)
Switch-on time typ. 2 s (1…13 s)
Switch-off time typ. 2 s (1…15 s)
Temperature jump, response time max. 12 s
Temperature gradient ð 250 K/min
Medium temperature -20…60 °C
Device designation É II 1/2 G EEx ia IIC T6
ignition protection category Ex ia IIC
PowerPið 0.69 W
Internal inductances/capacitances negligibly small
Ex approval acc. to conformity certificate TÜV 99 ATEX 1517X
Protection class IP67
Housing material Stainless steel, V4A (1.4571)
Sensor material stainless steel, AISI 316Ti
Max. tightening torque housing nut 30 Nm
Connection Flange connector, M12 x 1
Pressure resistance 60 bar
Process connection G ½″
■ATEX category II 1/2 G, Ex zone 0
■Intrinsically safe flow sensor for liquid
media
■Calorimetric principle
■Adjustment via potentiometer at Ex sig-
nal processor
■Status indicated via LED chain on sig-
nal processor
■Sensor length 65 mm
■Intrinsically safe EEx ia IIC T6, for use
in zone 0
■Plug-in device, M12 x 1
■4-wire connection to an Ex0 processor
Wiring Diagram
Functional principle
Our insertion - flow sensors operate on the
principle of thermodynamics. The measur-
ing probe is heated by several °C as against
the flow medium. When fluid moves along the
probe, the heat generated in the probe is dis-
sipated. The resulting temperature is mea-
sured and compared to the medium tempera-
ture. The flow status of every medium can be
derived from the evaluated temperature differ-
ence. Thus TURCK's wear-free flow sensors
reliably monitor the flow of gaseous and liquid
media.
Flow monitoring
Immersion sensor without integrated processor
FCS-G1/2A4-NAEX0-H1141/L065
Edition • 2016-06-25T23:45:41+02:00
2 / 2 Hans Turck GmbH & Co.KG ñ D-45472 Mülheim an der Ruhr ñ Witzlebenstraße 7 ñ Tel. 0208 4952-0 ñ Fax 0208 4952-264 ñ [email protected] ñ www.turck.com
Operating manual
Intended use
This device fulfils the directive 94/9/EC and is suited for use in explosion hazardous areas according to EN50014, EN50020 and EN50284.
For use in explosion hazardous areas conform to classification
II 1 G (Group II, Category 1 G, electrical equipment for gaseous atmospheres).
Marking (see device or technical data sheet)
É II 1/2 G and EEx ia IIC T6 acc.to EN50020 and EN50284
Installation / Commissioning
These devices may only be installed, connected and operated by trained and qualified staff. Qualified staff must have knowledge of protection
classes, directives and regulations concerning electrical equipment designed for use in explosion hazardous areas.
Please verify that the classification and the marking on the device comply with the actual application conditions.
This device is only suited for connection to approved EExi circuits acc. to EN500014 and EN50020. Please observe the maximum admissible
electrical values.
After connection to other circuits the sensor may no longer be used in EExi installations. When interconnected to (associated) electrical equip-
ment, it is required to perform the "Proof of intrinsic safety" (EN60079-14).
Installation and mounting instructions
Avoid static charging of cables and plastic devices. Please only clean the device with a damp cloth. Do not install the device in a dust flow and
avoid build-up of dust deposits on the device.
If the devices and the cable could be subject to mechanical damage, they must be protected accordingly. They must also be shielded against
strong electro-magnetic fields.
In order to avoid contamination of the device, please remove possible blanking plugs of the cable glands or connectors only shortly before in-
serting the cable or opening the cable socket.
service / maintenance
Repairs are not possible. The approval expires if the device is repaired or modified by a person other than the manufacturer. The most important
data from the approval are listed.

This manual suits for next models

1

Other turck Accessories manuals

turck PS310 Series User manual

turck

turck PS310 Series User manual

turck FTCI 2UP8X Series User manual

turck

turck FTCI 2UP8X Series User manual

turck RU Series User manual

turck

turck RU Series User manual

turck FCS-G1/2A4-NAEX-H1141 User manual

turck

turck FCS-G1/2A4-NAEX-H1141 User manual

turck FCS-G1/2A4-NAEX0/L065/D024 User manual

turck

turck FCS-G1/2A4-NAEX0/L065/D024 User manual

turck BCT Series User manual

turck

turck BCT Series User manual

turck RU40-M18 Series User manual

turck

turck RU40-M18 Series User manual

turck BC3-M12-AP6X 15M User manual

turck

turck BC3-M12-AP6X 15M User manual

turck Ri360P1-DSU35TC-ELi-Exi User manual

turck

turck Ri360P1-DSU35TC-ELi-Exi User manual

turck S120 User manual

turck

turck S120 User manual

turck RU U-M AP8X User manual

turck

turck RU U-M AP8X User manual

turck BI10-G30-Y2X 7M User manual

turck

turck BI10-G30-Y2X 7M User manual

turck FS100 L Series User manual

turck

turck FS100 L Series User manual

turck RU40-AP Series User manual

turck

turck RU40-AP Series User manual

turck NCLS Series User manual

turck

turck NCLS Series User manual

turck FCS-G NAEX Series User manual

turck

turck FCS-G NAEX Series User manual

turck BCT-M-IOL Series User manual

turck

turck BCT-M-IOL Series User manual

turck FCS-G1/2A4-NAEX0/L065 User manual

turck

turck FCS-G1/2A4-NAEX0/L065 User manual

turck FCS-GL1/2TN-NAEX-H1141 User manual

turck

turck FCS-GL1/2TN-NAEX-H1141 User manual

turck RU D UPN8X2 Series User manual

turck

turck RU D UPN8X2 Series User manual

turck RU10 M08 Series User manual

turck

turck RU10 M08 Series User manual

turck IM18-CCM40 User manual

turck

turck IM18-CCM40 User manual

turck BI1.5-HS865-Y1 User manual

turck

turck BI1.5-HS865-Y1 User manual

turck CMVT Series User manual

turck

turck CMVT Series User manual

Popular Accessories manuals by other brands

Monacor IMG STAGELINE MCS-180 operating instructions

Monacor

Monacor IMG STAGELINE MCS-180 operating instructions

Siko MSA510/1 quick start guide

Siko

Siko MSA510/1 quick start guide

Vega VEGAPULS 66 Quick setup guide

Vega

Vega VEGAPULS 66 Quick setup guide

Oregon Scientific THC238 user manual

Oregon Scientific

Oregon Scientific THC238 user manual

Coartal EOS Veranda Assembly instructions

Coartal

Coartal EOS Veranda Assembly instructions

Bugaboo Fox manual

Bugaboo

Bugaboo Fox manual

WilTec 51073 Operation manual

WilTec

WilTec 51073 Operation manual

KoamTac SMARTSLED KDC400 Series quick start guide

KoamTac

KoamTac SMARTSLED KDC400 Series quick start guide

SENSTAR FiberPatrol FP1100X Series Site Planning & Installation Guide

SENSTAR

SENSTAR FiberPatrol FP1100X Series Site Planning & Installation Guide

AQ Bio AD3880 user manual

AQ Bio

AQ Bio AD3880 user manual

Aron QBox user manual

Aron

Aron QBox user manual

Renishaw OLP40 quick start guide

Renishaw

Renishaw OLP40 quick start guide

Omron E3M-V - manual

Omron

Omron E3M-V - manual

ORION TELESCOPES & BINOCULARS 5302 instruction manual

ORION TELESCOPES & BINOCULARS

ORION TELESCOPES & BINOCULARS 5302 instruction manual

ESI Waveterminal 192 manual

ESI

ESI Waveterminal 192 manual

BCP SKY2603 instruction manual

BCP

BCP SKY2603 instruction manual

Campbell DB1 instruction manual

Campbell

Campbell DB1 instruction manual

Gogen PB 200008 S installation manual

Gogen

Gogen PB 200008 S installation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.