Page 1 of 2 AUGUST 2022 TFP334
Worldwide
Contacts
www.tyco-fire.com
IMPORTANT
Refer to Technical Data Sheet
TFP2300 for warnings pertaining to
regulatory and health information.
Always refer to Technical Data
Sheet TFP700 for the “INSTALLER
WARNING” that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently damage
a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Scan the QR code or enter the URL
in a web browser to access the most
up-to-date electronic version of this
document. Data rates may apply.
docs.jci.com/tycore/tfp334
Model Ultra K34
Standard Coverage Upright Storage Sprinkler
K-factor 33.6 (487)
General
Description
The TYCO Model Ultra K34 Standard
Coverage Upright Storage Sprinkler is
an FM Approved standard response,
standard coverage sprinkler for dry or
preaction systems. The sprinkler offers
a maximum coverage area of 100 ft²
(9,3 m²).
The Model Ultra K34 Sprinkler has
successfully undergone full-scale
re testing at FM Global for ceiling-
only storage applications of Class III
commodities.
For more information, contact Johnson
Controls Technical Services.
NOTICE
The Model Ultra K34 Standard Cov-
erage Upright Storage Sprinkler
described herein must be installed
and maintained in compliance with this
document, as well as with the applica-
ble standards of the National Fire Pro-
tection Association (NFPA), in addition
to the standards of any other authori-
ties having jurisdiction (for example, FM
Global). Failure to do so may impair the
performance of these devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
Sprinkler
Identication
Number (SIN)
TY9101
Technical
Data
Approvals
FM Approved
Maximum Working Pressure
175 psi (12,1 bar)
Pipe Thread Connection
1-1/4 in. NPT
ISO 7-R 1 1/4
Discharge Coefficient
K=33.6 gpm/psi½(487 Lpm/bar½)
Temperature Ratings
286°F (141°C)
Maximum Coverage Area
100 ft² (9,3 m²)
Finish
Natural Brass
Physical Characteristics
Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass
Deector . . . . . . . . . . . . . . . . . . . . . . . . . Copper
Compression Screw . . . . . . . . . . Stainless Steel
Bulb (8 mm) . . . . . . . . . . . . . . . . . . . . . . . . . Glass
Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass
Sealing Assembly ..Beryllium Nickel w/TEFLON
Deector Nut. . . . . . . . . . . . . . . . . . . . . . . .Brass
Operation
When the glass bulb reaches its rated
temperature of 286°F (141°C), the glass
bulb bursts allowing the sprinkler to
activate and ow water.
Design Criteria
For design criteria, contact Johnson
Controls Technical Services .
Installation
Install the TYCO Model Ultra K34 Stan-
dard Coverage Upright Sprinkler in
accordance with this section.
General Instructions
Do not install any bulb type sprinkler
if the bulb is cracked or there is a loss
of liquid form the bulb. With the sprin-
kler held horizontal, a small air bubble
should be present. For the Model Ultra
K34 Sprinkler, the diameter of the air
bubble is approximately 9/32 in. (7,0
mm).
A leak-tight 1-1/4 in. NPT sprinkler joint
should be obtained by applying pipe-
thread sealant to the sprinkler threads
and wrench-tightening using only the
W-Type 26 Sprinkler Wrench (Ref.
Figure 2).
Sprinkler Installation
Install the Model Ultra K34 Upright
Sprinkler only in the upright position in
accordance with the following steps:
Step 1. Apply pipe-thread sealant to
the sprinkler threads.
TFP334
Page 2 of 2
NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association;
TEFLON is a trademark of The Chemours Company FC, LLC
1467 Elmwood Avenue, Cranston, RI 02910 | Telephone +1-401-781-8220
© 2022 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.
Step 2. Hand-tighten the sprinkler into
sprinkler tting. Do not apply force
to the glass bulb, and grasp only by
the lower ends of the frame arms and
wrench ats while hand-tightening.
Step 3. Apply the W-Type 26 Sprinkler
Wrench shown in Figure 2 to the sprin-
kler by fully seating the wrench recess
on the sprinkler wrench ats shown in
Figure 1.
Step 4. Wrench-tighten the sprinkler
to obtain a leak-tight joint, either 1 to
1-1/2 turns beyond hand-tightened or
by applying a minimum-to-maximum
torque of 30 ft-lb to 40 ft-lb (40 N·m
to 50 N·m).
NOTICE
Higher levels of torque may distort
sprinkler inlet with consequent leakage
or impairment of sprinkler.
Care and
Maintenance
The TYCO Model Ultra K34 Standard
Coverage Upright Sprinkler must be
maintained and serviced in accordance
with this section.
Before closing a re protection system
main control valve for maintenance
work on the re protection system
that it controls, obtain permission to
shut down the affected re protection
system from the proper authorities
and notify all personnel who may be
affected by this decision.
Inspection, testing, and maintenance
must be performed as indicated below
and in accordance with the local
requirements and/or national codes.
Any impairment must be immediately
corrected.
The owner is responsible for the
inspection, testing, and maintenance of
their re protection system and devices
in compliance with this document, as
well as with the applicable standards
of any authorities having jurisdiction.
Contact the installing contractor or
product manufacturer regarding any
questions.
Automatic sprinkler systems are rec-
ommended to be inspected, tested,
and maintained by a qualied Inspec-
tion Service in accordance with local
requirements and/or national codes.
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-re.com.
Ordering
Procedure
Contact your local distributor for avail-
ability. When placing an order, indicate
the full product description and Part
Number (P/N).
Sprinkler Assembly with
1-1/4 Inch NPT Thread Connection
Specify: Model Ultra K34 Standard
Coverage Upright Sprinkler, SIN
TY9101, 286°F (141°C), natural brass,
P/N 51-688-1-286
Special Order
Sprinkler Assembly with
ISO 7-1 Thread Connection
Specify: Model Ultra K34 Standard
Coverage Upright Sprinkler, SIN
TY9101 with ISO 7-R 1 1/4 thread con-
nection, 286°F (141°C), natural brass,
P/N 51-689-1-286
Sprinkler Wrench
Specify: W-Type 26 Sprinkler Wrench,
P/N 56-341-1-001
Deector
Frame
Bulb
Deector Nut Sealing Assembly
ButtonScrew
Compression
-
-
-
- -
-
-
2
1
5
4 6
7
3
TEMPERATURE
WRENCH
FLATS
NPT
1-1/4"
CENTER OF
THERMAL
ELEMENT
RATING
(103,2 mm)
4-1/16"
(15,9 mm)
NOMINAL
MAKE-IN
5/8"
(44,5 mm)
1-3/4"
(77,8 mm)
3-1/16" DIA.
3
4
2
5
7
6
1
FIGURE 1
MODEL ULTRA K34 STANDARD COVERAGE
UPRIGHT SPRINKLER
"SPRINKLER
SIDE"
TOWARDS
SPRINKLER
WRENCH
RECESS
FIGURE 2
W-T Y PE 2 6
SPRINKLER WRENCH
TFP334
Change History Appendix
Worldwide
Contacts
www.tyco-fire.com
1467 Elmwood Avenue, Cranston, RI 02910 | Telephone +1-401-781-8220
© 2022 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.
ISSUE DATE NOTES
08-22
Page 1, added QR code and URL to allow convenient access to electronic version from printed docu-
ment; Page 2, changed corporate address and telephone number to 1467 Elmwood Avenue, Cranston,
RI 02910 | Telephone +1-401-781-8220, formerly 1400 Pennbrook Parkway, Lansdale, PA 19446 | Tele-
phone +1-215-362-0700.
08-18
Updated Tyco® branding and document format; Added Johnson Controls copyright; Added disclaimer
stating specications and information subject to change without notice; Added reference to Regulatory
and Health Warning Technical Data Sheet TFP2300.
09-16 Clarifed wrench-tightening requirements in Installation procedure.
08-16 Rev A Updated sprinkler approvalsto FM Approved; formerly FM Tested.
08-16 Expanded re protection system compatibility to include double interlock preaction systems.
06-16 New Technical Data Sheet TFP334 describes the Model Ultra K34 Standard Coverage Upright Storage
Sprinkler.

Other Tyco Irrigation System manuals

Tyco FTR-1 User manual

Tyco

Tyco FTR-1 User manual

Tyco TY-B Series User manual

Tyco

Tyco TY-B Series User manual

Tyco TFP485 User manual

Tyco

Tyco TFP485 User manual

Tyco RFII-C Series User manual

Tyco

Tyco RFII-C Series User manual

Tyco LFII Series User manual

Tyco

Tyco LFII Series User manual

Tyco TFP PH2 Instruction Manual

Tyco

Tyco TFP PH2 Instruction Manual

Tyco Rapidresponse LFII Series User manual

Tyco

Tyco Rapidresponse LFII Series User manual

Tyco RFII Series User manual

Tyco

Tyco RFII Series User manual

Tyco K17-231 User manual

Tyco

Tyco K17-231 User manual

Tyco ESFR-17 User manual

Tyco

Tyco ESFR-17 User manual

Tyco ESFR-17 User manual

Tyco

Tyco ESFR-17 User manual

Tyco RFII Series User manual

Tyco

Tyco RFII Series User manual

Tyco ELO-231 Series User manual

Tyco

Tyco ELO-231 Series User manual

Tyco TY-FRB Series User manual

Tyco

Tyco TY-FRB Series User manual

Tyco Ultra K17 K-factor User manual

Tyco

Tyco Ultra K17 K-factor User manual

Tyco ESFR-25 User manual

Tyco

Tyco ESFR-25 User manual

Tyco DS-8 Series User manual

Tyco

Tyco DS-8 Series User manual

Tyco TY-L Series User manual

Tyco

Tyco TY-L Series User manual

Tyco D4a User manual

Tyco

Tyco D4a User manual

Tyco TY7158 User manual

Tyco

Tyco TY7158 User manual

Tyco TY-B Series User manual

Tyco

Tyco TY-B Series User manual

Tyco Gem F916 User manual

Tyco

Tyco Gem F916 User manual

Tyco TY-L Series User manual

Tyco

Tyco TY-L Series User manual

Tyco DS-1 Series User manual

Tyco

Tyco DS-1 Series User manual

Popular Irrigation System manuals by other brands

Viking FREEDOM VK486 Technical data

Viking

Viking FREEDOM VK486 Technical data

Viking MICROFAST VK345 Technical data

Viking

Viking MICROFAST VK345 Technical data

Rivulis Rivulite-aqua instruction manual

Rivulis

Rivulis Rivulite-aqua instruction manual

Tyco Fire Product Gem F916 instruction manual

Tyco Fire Product

Tyco Fire Product Gem F916 instruction manual

Eden 95144EDAMZ quick start guide

Eden

Eden 95144EDAMZ quick start guide

Autopot 80 Pot Systems Set-up guidelines

Autopot

Autopot 80 Pot Systems Set-up guidelines

Autopot 80Pot XL Set-up guidelines

Autopot

Autopot 80Pot XL Set-up guidelines

Signature 6700 Pro Impact instruction manual

Signature

Signature 6700 Pro Impact instruction manual

Viking VK510 Technical data

Viking

Viking VK510 Technical data

Eden 94141EDAMZ quick start guide

Eden

Eden 94141EDAMZ quick start guide

Autopot SmartPot 48 XL Set-up guidelines

Autopot

Autopot SmartPot 48 XL Set-up guidelines

Victaulic VicFlex Style AB6 quick start guide

Victaulic

Victaulic VicFlex Style AB6 quick start guide

Tyco Fire Product CENTRAL Optima instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL Optima instruction manual

Johnson Controls tyco AQUAMIST IFP manual

Johnson Controls

Johnson Controls tyco AQUAMIST IFP manual

Tyco Fire Product CENTRAL H-1 instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL H-1 instruction manual

Eden 94803-EDAMZ quick start guide

Eden

Eden 94803-EDAMZ quick start guide

CPG FirePex manual

CPG

CPG FirePex manual

Munters Green Field DC user manual

Munters

Munters Green Field DC user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.