manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Tyco
  6. •
  7. Irrigation System
  8. •
  9. Tyco TY-FRB Series User manual

Tyco TY-FRB Series User manual

Other manuals for TY-FRB Series

17

This manual suits for next models

2

Other Tyco Irrigation System manuals

Tyco Rapidresponse LFII Series User manual

Tyco

Tyco Rapidresponse LFII Series User manual

Tyco AquaMist AM4 User manual

Tyco

Tyco AquaMist AM4 User manual

Tyco FASTFLEX YN25 User manual

Tyco

Tyco FASTFLEX YN25 User manual

Tyco ELO-231FRB Series User manual

Tyco

Tyco ELO-231FRB Series User manual

Tyco ELO-231B Series User manual

Tyco

Tyco ELO-231B Series User manual

Tyco DS-1 Series User manual

Tyco

Tyco DS-1 Series User manual

Tyco TY-B Series User manual

Tyco

Tyco TY-B Series User manual

Tyco D Quartzoid TY3191 User manual

Tyco

Tyco D Quartzoid TY3191 User manual

Tyco TY-FRB Series User manual

Tyco

Tyco TY-FRB Series User manual

Tyco F950 User manual

Tyco

Tyco F950 User manual

Tyco RFII-C Series User manual

Tyco

Tyco RFII-C Series User manual

Tyco TY-FRB Series User manual

Tyco

Tyco TY-FRB Series User manual

Tyco TY-FRL Series User manual

Tyco

Tyco TY-FRL Series User manual

Tyco TY-B Series User manual

Tyco

Tyco TY-B Series User manual

Tyco ILLUSION User manual

Tyco

Tyco ILLUSION User manual

Tyco TY-B Series User manual

Tyco

Tyco TY-B Series User manual

Tyco TY-B Series User manual

Tyco

Tyco TY-B Series User manual

Tyco DS-1 Series User manual

Tyco

Tyco DS-1 Series User manual

Tyco Gem PSN 56-701-9-010 User manual

Tyco

Tyco Gem PSN 56-701-9-010 User manual

Tyco TY-FRL Series User manual

Tyco

Tyco TY-FRL Series User manual

Tyco Rapidresponse LFII Series User manual

Tyco

Tyco Rapidresponse LFII Series User manual

Tyco EC-11 Series User manual

Tyco

Tyco EC-11 Series User manual

Tyco TY7158 User manual

Tyco

Tyco TY7158 User manual

Tyco EC-8 Series User manual

Tyco

Tyco EC-8 Series User manual

Popular Irrigation System manuals by other brands

Toro ZSERIES 570Z brochure

Toro

Toro ZSERIES 570Z brochure

OpenSprinkler OSPi user manual

OpenSprinkler

OpenSprinkler OSPi user manual

EINHELL GE-WW 5537 E Original operating instructions

EINHELL

EINHELL GE-WW 5537 E Original operating instructions

Hunter Institutional Series instructions

Hunter

Hunter Institutional Series instructions

Cellfast 52-305 user manual

Cellfast

Cellfast 52-305 user manual

Tyco Fire Product Star Galaxy SGQR instruction manual

Tyco Fire Product

Tyco Fire Product Star Galaxy SGQR instruction manual

Tyco Fire Product CENTRAL A instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL A instruction manual

Oral Care Technologies Hydro Floss Instructions for use

Oral Care Technologies

Oral Care Technologies Hydro Floss Instructions for use

Reliable F1-300 quick start guide

Reliable

Reliable F1-300 quick start guide

Tyco Fire Product Gem F892 instruction manual

Tyco Fire Product

Tyco Fire Product Gem F892 instruction manual

Irrigation-Mart KIT-GK100-RV-B quick start guide

Irrigation-Mart

Irrigation-Mart KIT-GK100-RV-B quick start guide

Reliable F4FR quick start guide

Reliable

Reliable F4FR quick start guide

Valley Bender160 owner's manual

Valley

Valley Bender160 owner's manual

Reliable F1FR42 Series manual

Reliable

Reliable F1FR42 Series manual

Toro 730 Series Installation and service instructions

Toro

Toro 730 Series Installation and service instructions

Eden 97063-EDAMZ quick start guide

Eden

Eden 97063-EDAMZ quick start guide

Netafim NETBEAT user manual

Netafim

Netafim NETBEAT user manual

Tyco Fire Product CENTRAL ELO-231 instruction manual

Tyco Fire Product

Tyco Fire Product CENTRAL ELO-231 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Series TY-FRB – 5.6 K-factor
Conventional (Old Style) Sprinklers
Quick Response
Page 1 of 4 FEBRUARY 2015 TFP667
IMPORTANT
Always refer to Technical Data
Sheet TFP700 for the “INSTALLER
WARNING” that provides cautions
with respect to handling and instal-
lation of sprinkler systems and com-
ponents. Improper handling and
installation can permanently dam-
age a sprinkler system or its compo-
nents and cause the sprinkler to fail
to operate in a fire situation or cause
it to operate prematurely.
Worldwide
Contacts
www.tyco-fire.com
General
Description
The TYCO Series TY-FRB, 5.6 K-fac-
tor, Conventional Sprinklers, Quick
Response described in this technical
data sheet are quick response, stan-
dard coverage, decorative 3 mm glass
bulb type spray sprinklers. These sprin-
klers are intended to be installed either
pendent or upright, and in either posi-
tion, they produce a spherical water
discharge pattern with approximately
50% of the discharge directed upwards
and approximately 50% of the dis-
charge directed downwards.
Conventional sprinklers are gener-
ally used with Ordinary and Extra High
Hazard Class Systems, as dened by
the automatic sprinkler system instal-
lation rules of the country and author-
ity having jurisdiction. The National Fire
Protection Association (NFPA) permits
the use of “Old Style Sprinklers” where
special construction features require a
unique water distribution; for the pro-
tection of fur vaults; or, the replace-
ment of similar sprinklers that had been
installed prior to 1955.
NOTICE
The Series TY-FRB Sprinklers de-
scribed herein must be installed and
maintained in compliance with this doc-
ument, as well as with the applicable
standards of the National Fire Protec-
tion Association, in addition to the stan-
dards of any other authorities having
jurisdiction. Failure to do so may impair
the performance of these devices.
The owner is responsible for main-
taining their fire protection system
and devices in proper operating con-
dition. Contact the installing contrac-
tor or product manufacturer with any
questions.
Sprinkler
Identification
Numbers (SINs)
TY363
TY3630 (LPCB Approved only)
Technical
Data
Approvals
UL and C-UL Listed
VdS Approved
LPCB Approved (TY3630 only)
Sprinklers with Polyester Finish are UL
and C-UL Listed as Corrosion-Resis-
tant Sprinklers.
Maximum Working Pressure
175 psi (12,1 bar)
Discharge Coefficient
K=5.6 gpm/psi1/2 (80,6 lpm/bar1/2)
Temperature Ratings
135°F (57°C)
155°F (68°C)
175°F (79°C)
200°F (93°C)
286°F (141°C)
Finishes
Sprinkler: Refer to Table A.
Physical Characteristics
Frame ....................................................... Bronze
Button ............................................ Brass/Copper
Sealing Assembly ..........................Stainless Steel
w/TEFLON
Bulb ............................................................ Glass
Compression Screw .................................. Bronze
Deector .................................................... Bronze
Operation
The glass bulb contains a uid which
expands when exposed to heat. When
the rated temperature is reached, the
uid expands sufciently to shatter the
glass bulb, allowing the sprinkler to
activate and water to ow.
Design
Criteria
The TYCO Series TY-FRB, 5.6 K-fac-
tor, Conventional Sprinklers, Quick
Response are intended for re protec-
tion systems designed in accordance
with the standard installation rules rec-
ognized by the applicable Listing or
Approval agency (e.g., UL Listing is
based on NFPA 13 requirements). The
Series TY-FRB Conventional Sprinklers
are only for non-recessed applications.
TFP667
Page 2 of 4
Installation
The TYCO Series TY-FRB, 5.6 K-fac-
tor, Conventional Sprinklers, Quick
Response must be installed in accor-
dance with this section.
General Instructions
Do not install any bulb type sprinkler if
the bulb is cracked or there is a loss
of liquid from the bulb. With the sprin-
kler held horizontally, a small air bubble
should be present. The diameter of the
air bubble is approximately 1/16 inch
(1,6 mm) for the 135°F (57°C) to 3/32
inch (2,4 mm) for the 286°F (141°C) tem-
perature ratings.
A leak-tight 1/2 inch NPT sprinkler joint
should be obtained with a torque of 7 to
14 ft.-lbs. (9,5 to 19,0 Nm). Higher levels
of torque may distort the sprinkler inlet
and cause leakage or impairment of the
sprinkler.
Step 1. With pipe thread sealant
applied to the pipe threads, hand
tighten the sprinkler into the sprinkler
tting.
Step 2. Tighten the sprinkler into the
sprinkler tting using only the W-Type
6 Sprinkler Wrench (Ref. Figure 2).
With reference to Figure 1, the W-Type
6 Sprinkler Wrench is to be applied to
the wrench ats.
Care and
Maintenance
The TYCO Series TY-FRB, 5.6 K-fac-
tor, Conventional Sprinklers, Quick
Response must be maintained and ser-
viced in accordance with this section.
Before closing a re protection system
main control valve for maintenance
work on the re protection system
that it controls, obtain permission to
shut down the affected re protection
systems from the proper authorities
and notify all personnel who may be
affected by this action.
Sprinklers which are found to be leak-
ing or exhibiting visible signs of corro-
sion must be replaced.
Automatic sprinklers must never be
painted, plated, coated, or other-
wise altered after leaving the factory.
Modied sprinklers must be replaced.
Sprinklers that have been exposed to
corrosive products of combustion, but
have not operated, should be replaced
if they cannot be completely cleaned
by wiping the sprinkler with a cloth or
by brushing it with a soft bristle brush.
Care must be exercised to avoid dam-
age to the sprinklers before, during, and
after installation. Sprinklers damaged
by dropping, striking, wrench twist/
slippage, or the like, must be replaced.
Also, replace any sprinkler that has a
cracked bulb or that has lost liquid from
its bulb. (Refer to Installation Section.)
The owner is responsible for the
inspection, testing, and maintenance of
their re protection system and devices
in compliance with this document, as
well as with the applicable standards
of the National Fire Protection Asso-
ciation (e.g., NFPA 25), in addition to
the standards of any other authorities
having jurisdiction. Contact the install-
ing contractor or product manufacturer
with any questions.
It is recommended that automatic
sprinkler systems be inspected, tested,
and maintained by a qualied Inspec-
tion Service in accordance with local
requirements and/or national codes.
CROSS SECTION
SHOWN UPRIGHT
SHOWN
PENDENT
6
-Deector
5
-
4
-
Compression
Screw
Bulb
Components:
-
2
3
-
1
-
Button
Sealing
Assembly
Frame
1-3/8"
(34,9 mm)
2"
(50,8 mm)
WRENCH
FLATS
7/16" (11,1 mm)
NOMINAL
MAKE-IN
ESCUTCHEON PLATE
SEATING SURFACE
1/2"
NPT
2
1
3
*
Temperature
rating is indicated
on Deector.
*4
5
6
*
**
Pipe thread
connections per
ISO 7-1 can be
provided on
special request.
**
WRENCH RECESS
(USE ONLY
END "A")
FIGURE 1
SERIES TY-FRB CONVENTIONAL SPRINKLERS (TY363 & TY3630)
5.6 K-FACTOR, 1/2 INCH NPT, QUICK RESPONSE
FIGURE 2
W-TYPE 6
SPRINKLER WRENCH
TFP667
Page 3 of 4
Limited
Warranty
For warranty terms and conditions, visit
www.tyco-re.com.
Ordering
Procedure
Contact your local distributor for
availability. When placing an order,
indicate the full product name and
Part Number (P/N).
Sprinkler Assemblies with
NPT Thread Connections
Specify: Series TY-FRB Conventional
Sprinkler, (specify) SIN, K=5.6, Quick
Response, (specify) temperature rat-
ing), (specify) nish, P/N (specify, refer
to Table A)
Sprinkler Wrench
Specify: W-Type 6 Sprinkler Wrench,
P/N 56-000-6-387
SPRINKLER
FINISH
1NATURAL
BRASS
3PURE WHITE (RAL9010)***
POLYESTER
4SIGNAL WHITE (RAL9003)
POLYESTER
9CHROME
PL ATED
TEMPERATURE
RATINGS
135 135°F (57°C)
155 155°F (68°C)
175 175°F (79°C)
200 200°F (93°C)
286 286°F (141°C)
P/N* 77 – XXX – X – XXX
SIN
373 5.6K CONVENTIONAL TY363
373 5.6K CONVENTIONAL TY3630**
Notes:
* Use sufx “I” for ISO 7-1 connection (e.g., 77-373-4-175-I)
** LPCB Approved Series TY-B Conventional Sprinkler as-
semblies only: Use sufx “L” for LPCB Approved assem-
blies (e.g., 77-373-4-175-L or 77-373-4-175-IL for LPCB
Approved and ISO 7-1 connection)
*** Eastern Hemisphere sales only
TABLE A
PART NUMBER SELECTION
SERIES TY-FRB CONVENTIONAL SPRINKLERS
GLOBAL HEADQUARTERS | 1400 Pennbrook Parkway, Lansdale, PA 19446 | Telephone +1-215-362-0700
TFP667
Page 4 of 4
Copyright © 2015 Tyco Fire Products, LP. All rights reserved.
TEFLON is trademark of The DuPont Corporation.