Uponor Smatrix Base Pro User manual

10 | 2017
Uponor Smatrix
Base PRO
EN QUICK GUIDE

Contents
Uponor Smatrix Base PRO components .......................2
System example ................................................................2
Safety instructions .......................................................3
Controller..........................................................................3
Thermostat/System device ...............................................3
Quick Guide ...................................................................5
Installation ........................................................................5
Register thermostat and/or system device to a
controller...........................................................................7
Register multiple controllers..............................................8
Unregister one channel or system device ..........................8
Unregister all channels......................................................8
Room bypass.....................................................................8
Communications protocol..................................................8
Other functions.................................................................8
Technical data ...............................................................9
Uponor Smatrix Base
PRO components
An Uponor Smatrix Base PRO system may be a
combination of the following components:
• Uponor Smatrix Base PRO Controller X-147
(controller)
• Uponor Smatrix Base PRO Interface I-147
(interface)
• Uponor Smatrix Base Thermostat D+RH T-149
(digital thermostat T-149)
• Uponor Smatrix Base Thermostat Prog.+RH T-148
(digital thermostat T-148)
• Uponor Smatrix Base Thermostat Dig T-146 (digital
thermostat T-146)
• Uponor Smatrix Base Thermostat Standard T-145
(standard thermostat T-145)
• Uponor Smatrix Base Thermostat Flush T-144 (flush
thermostat T-144)
• Uponor Smatrix Base Thermostat Public T-143
(public thermostat T-143)
• Uponor Smatrix Base PRO Room Sensor+RH T-141
(sensor thermostat T-141)
• Uponor Smatrix Base Slave Module M-140 (slave
module M-140)
• Uponor Smatrix Base Star Module M-141 (star
module M-141)
• Uponor Smatrix Transformer A-1XX (transformer
A-1XX)
System example
1234
1234
https://www.uponor.com/smatrix/downloads.aspx
Uponor Smatrix
Base PRO
UK INSTALLATION AND OPERATION
MANUAL
Uponor Smatrix
Base PRO
UK INSTALLATION AND OPERATION
MANUAL
Uponor Smatrix
Base PRO
UK INSTALLATION AND OPERATION
MANUAL
NOTE!
This is a quick start guide to serve as a
reminder for experienced installers. We
strongly recommend reading the full manual
before installing the control system. See QR-
code for download link.
QUICK GUIDE
2
UPONOR SMATRIX BASE PRO · QUICK GUIDE
EN
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SI
SK

Safety instructions
This quick start guide to serves as a reminder for
experienced installers. We strongly recommend reading
the full manual before installing the control system.
Controller
Warning!
The Uponor system uses 50 Hz, 230 V AC
power. In case of emergency, immediately
disconnect the power.
Warning!
Electrical installation and service behind
secured 230 V AC covers must be carried
out under the supervision of a qualified
electrician.
Warning!
The transformer module is heavy and might
detach if the controller is held upside down
without the cover on.
Caution!
To avoid interference, keep installation/data
cables away from power cables of more than
50 V.
Caution!
Ensure that each actuator is connected to the
correct channel so that the thermostats are
controlling the correct loops.
NOTE!
Wires between transformer and controller card
needs to be disconnected prior to detaching.
NOTE!
Connect only one actuator for each channel.
Channels 01 and 02 have double outputs (a
and b) for two actuators.
Thermostat/System device
NOTE!
Registration of at least one thermostat must
be done before registering a system device.
NOTE!
Up to 16 controllers can be registered to an
interface.
Caution!
If more than one controller is available in the
system, register the thermostat as a system
device to the master controller.
Caution!
The switches in public the thermostat must
be set before the thermostat is registered.
Caution!
The switches, in the public thermostat, must
be set to one of the available functions,
otherwise it cannot be registered.
QUICK GUIDE
3
UPONOR SMATRIX BASE PRO · QUICK GUIDE
EN
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SI
SK

X-147
M-140*
M-141*
1
32
4 5
2.1
2.2
3.1
2.4
2.1
76 8
X-147
M-140*
M-141*
X-147
T-148
T-146
T-145
T-143
T-144
T-141
T-149
2.3
1.2
1.1 1.1 1.1
1.2
1.2
1.1
1.2
1.2
+- +-
+- +- +-
BABA
BABABA
3.3
3.3
3.1
4.2
3.3
3.1
3.2
4.2
3.3
4.1
X-147
M-140*
4.2
4.3
4.1
4.1
4.2
+-AB
4.1
A-AB B-
X-147
I-147
5.1
5.1
5.2
5.3
5.3
A
B
-
N
L
6.1
6.2
4.1
4.2
T-143
1 2 3 4
ON DIP
T-148
T-146 T-145 T-143T-149
T-148
T-146
T-143
T-149
99.4
9.3
9.1
9.1
9.2
9.2
*Option*Option
*Option
Option
QUICK GUIDE
4
UPONOR SMATRIX BASE PRO · QUICK GUIDE
EN
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SI
SK

9. Connect optional external sensor (compatible
thermostats only) and set the DIP switch (public
thermostat T-143 only).
Function* Switch
Standard room thermostat
1234
ON DIP
Standard room thermostat together with a
floor temperature sensor
1234
ON DIP
Standard room thermostat, or system device,
together with an outdoor temperature sensor
1234
ON DIP
System device together with a supply
temperature sensor for heating/cooling
switch over function
1234
ON DIP
System device where the sensor input is used
for Comfort/ECO switch over function **
1234
ON DIP
Remote sensor
1234
ON DIP
* The thermostat can only be registered as a system device to a
Base PRO system with multiple controllers, if it is registered to
the master controller.
** Closed = ECO
10. Connect the power cable to a 230 V AC wall socket,
or if required by local regulations, to a junction box.
11. Select thermostat control mode (settings menu 04,
in digital thermostats only). Default: RT (standard
room thermostat).
Register thermostats, the interface and other system
devices, in that order (next page).
Quick Guide
Installation
1. Attach the full assembly, or parts of it, to the wall
either with a DIN rail or by using wall screws and
plugs.
2. Connect the actuators.
3. Connect a thermostat communication cable to
the controller, slave module, and/or the optional
star module. Note: Daisy chain bus topology
is recommended. See page 8, Communications
protocol for more information.
4. Connect a thermostat communication cable to the
thermostat/timer.
5. Connect a system bus communication cable
in between controllers and route one cable to
the interface. Note: Daisy chain bus topology
is recommended. See page 8, Communications
protocol for more information.
6. Connect a system bus communication cable (7.1)
and a power cable (7.2) to the interface.
7. Check that all wiring is complete and correct:
• Actuators
• Heating/cooling switch
• Circulation pump
8. Ensure that the 230 V AC compartment of the
controller is closed and the fixing screw is tightened.
X-147
10 11
3 s
3 s
T-148
T-146
T-149
11.1
11.2
T-148
T-146
T-149
11.3
11.4
T-148
T-146
T-149
11.5
11.2 11.4
04
QUICK GUIDE
5
UPONOR SMATRIX BASE PRO · QUICK GUIDE
EN
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SI
SK

12 13
14
14
15
16
16
13.1
13.1
13.1 13.3
5 s
5 s
13.2
3 s
5 s
T-146
T-148
T-144
T-149
T-141 T-145
5 s
5 s
T-143
5 s
17
19
19
16.1 16.2
16.4
I-147
English Español
Português
Deutsch
Italiano
Français
Suomi
Svenska
18
01 02 03 04 05 06
17.1
17.2
17.3
17.1 16.3
3 s
16.3
5 s
T-143
I-147
T-143
T-149
T-148
T-146
T-145
T-144
T-143
T-141
12
Link OK
Link Touch Screen to controller
QUICK GUIDE
6
UPONOR SMATRIX BASE PRO · QUICK GUIDE
EN
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SI
SK

Register thermostat and/or system device
to a controller
To register room thermostats and system devices (interface
etc.) to the controller:
Enter registration mode
12. Press and hold the OK button on the controller, for
about 3 seconds, until the LED for channel 1 (or the
first unregistered channel) flashes red.
Register a thermostat
13. Select a thermostat channel.
13.1 Use buttons <or >to move the pointer (LED
flashes red) to a preferred channel.
13.2 Press the OK button to select the channel for
registration. The LED for the selected channel
starts flashing green.
13.3 Repeat steps 13.1 and 13.2 until all channels to
be registered with the thermostat are selected
(LEDs flashing green).
Note! It is recommended to register all channels
to the thermostat at the same time.
14. Select a thermostat.
THERMOSTAT T-143 AS A THERMOSTAT, WITH
VARIOUS FUNCTIONS
14.1 Gently press and hold the registration button
on the thermostat, release when the LED starts
flashing green (located in the hole above the
registration button).
The selected channel LED in the controller turns
fixed green and the registration is complete.
THERMOSTAT T-144
14.1 Using a pointed instrument, gently press and hold
the registration button on the thermostat, release
when the LED above the dial starts flashing.
The selected channel LED in the controller turns
fixed green and the registration is complete.
THERMOSTAT T-141 AND T-145
14.1 Gently press and hold the registration button
on the thermostat, release when the LED on the
front of the thermostat starts flashing.
The selected channel LED in the controller turns
fixed green and the registration is complete.
THERMOSTATS T-146, T-148 AND T-149
14.1 Press and hold both -and +buttons (T-149
= and ) on the thermostat until the text
CnF (configure) and a communication icon is
displayed.
The selected channel LED in the controller turns
fixed green and the registration is complete.
15. Repeat steps 13 and 14 until all available thermostats
are registered.
Register a system device (I-147 etc)
NOTE!
At least one thermostat must be registered before
registering a system device.
16. Make sure to be in registration mode (step 12).
16.1 Use buttons <or >to move the pointer to the
power LED (LED flashes red).
16.2 Press the OK button to enter system channel
registration mode. The power LED flashes
according to the pattern long blink, short pause,
long blink and channel 1 LED flashes red.
16.3 Select a system channel, see list below.
1 = Touch screen interface
2 = Not used
3 = Public thermostat with outdoor sensor
4 = Public thermostat with heating/cooling
switch from sensor input.
5 = Public thermostat with Comfort/ECO switch
16.4 Press the OK button to select system device
channel. The channel LED starts flashing green
17. Select a system device matching the system channel.
INTERFACE I-147
17.1. Power up the interface and attach it to the
charger.
17.2. Follow the startup guide in the interface up until
registration.
17.3 Press Link Touch Screen to controller in the
Startup guide, or Link menu (Main menu >
Preferences), to initialize registration.
17.4 The interface gets registered to the controller.
The selected channel LED in the controller turns
fixed green and the registration is complete.
THERMOSTAT T-143 AS A SYSTEM DEVICE, WITH
VARIOUS FUNCTIONS
17.1 Gently press and hold the registration button
on the thermostat, release when the LED starts
flashing green (located in the hole above the
registration button).
The selected channel LED in the controller turns
fixed green and the registration is complete.
18. Repeat steps 16 and 17 until all available system devices
are registered.
Exit registration mode
19. Press and hold the OK button on the controller, for
about 3 seconds, until the green LEDs turn off to end
registration and return to run mode.
QUICK GUIDE
7
UPONOR SMATRIX BASE PRO · QUICK GUIDE
EN
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SI
SK

Register multiple controllers
Up to 16 controllers can be registered to an interface.
All additional controllers in the system must be
registered to the interface.
NOTE!
At least one thermostat must be registered to
the additional controller before registering to
the interface.
See steps 16 and 17 in the “Register thermostat and/
or system device to a controller” section for more
information.
Unregister one channel or system device
When a channel or system device is inaccurately
registered or if a thermostat registration needs to be
redone, it is possible to remove the current registration
from the controller.
NOTE!
The controller must be unregistered in the
interface as well. Go to menu Main menu >
Preferences > Link and unregister.
To unregister a channel:
1. Enter registration mode. Channel 1 LED flashes red/
green, or the first unregistered channel flashes red.
2. If a system device (timer etc) is to be unregistered,
enter system channel registration mode. The power
LED flashes according to the pattern long blink,
short pause, long blink and channel 1 LED flashes
red/green.
3. Use buttons <or >to move the pointer (LED
flashes red) to the selected channel (flashes green if
registered) to unregister.
4. Press the < and >buttons simultaneously for about
5 seconds until the LED for the selected channel
starts flashing red.
Unregister all channels
When one or more channels are inaccurately registered,
it is possible to remove all registrations at the same
time.
NOTE!
The controller must be unregistered in the
interface as well. Go to menu Main menu >
Preferences > Link and unregister.
To cancel all channel registrations:
1. Enter registration mode. Channel 1 LED flashes red/
green, or the first unregistered channel flashes red.
2. Press the < and >buttons simultaneously for about
10 seconds until the LEDs for all channels except
one turn off. The one remaining flashes red.
Room bypass
To reach the bypass settings, the controller must be
registered to the interface.
1. In the interface, go to the Room bypass menu,
Main menu > System settings > Room bypass.
2. Select a controller.
3. Select up to a maximum of two rooms.
4. Press the Confirm button to save and exit the
menu.
Communications protocol
The system is based on a bus communications protocol
(requires the thermostats unique ID to be registered
to the controller), utilising daisy chain, direct or
star topology connections. This allows serial and
parallel connections, makes wiring and connection
of thermostats and system devices much easier than
connecting one thermostat per connection terminal.
The wide array of connection possibilities presented
with this communications protocol can be combined in
any way best suited for the current system.
Other functions
See full manual for more information about
Autobalancing of actuators (eliminating the need
of manual balancing,on by default), Heat pump
integration, Cooling, Comfort/ECO settings, KNX
module, Room check, and Supply check etc.
QUICK GUIDE
8
UPONOR SMATRIX BASE PRO · QUICK GUIDE
EN
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SI
SK

Technical data
General
IP IP20 (IP: degree of inaccessibility to active parts of the product
and degree of water)
Max. ambient RH (relative humidity) 85% at 20 °C
Thermostat
CE marking
ERP (thermostat only) IV
Low voltage tests EN 60730-1* and EN 60730-2-9***
EMC (electromagnetic compatibility requirements) tests EN 60730-1
Power supply From controller
Voltage 4.5 V to 5.5 V
Operating temperature 0 °C to +45 °C
Storage temperature -10 °C to +70 °C
Connection terminals (T-143, T-144, T-145, T-146, and T-148) 0.5 mm² to 2.5 mm²
Connection terminals (T-141 and T-149) 0.25 mm² to 0.75 mm² solid, or 0.34 mm² to 0.5 mm² flexible
with ferrules
Interface
CE marking
Low voltage tests EN 60730-1 and EN 60730-2-1
EMC (electromagnetic compatibility requirements) tests EN 60730-1
Power supply 230 V AC +10/-15%, 50 Hz in wall box or
mini USB connection
Operating temperature 0 °C to +45 °C
Storage temperature -20 °C to +70 °C
Controller/interface SD card
Type micro SDHC, UHS or Standard
Capacity 4 GB to 32 GB, FAT 32 formatting
Speed Class 4 to 10 (or higher)
Controller
CE marking
ERP VIII
Low voltage tests EN 60730-1* and EN 60730-2-1**
EMC (electromagnetic compatibility requirements) tests EN 60730-1
Power supply 230 V AC +10/-15%, 50 Hz or 60 Hz
Internal fuse T5 F3.15AL 250 V, 5x20 3.15A quick acting
Operating temperature 0 °C to +45 °C
Storage temperature -20 °C to +70 °C
Maximum consumption 45 W
Pump and boiler relay outputs 230 V AC +10/-15%, 250 V AC 8 A maximum
General purpose input (GPI) Only dry contact
Heat pump input 12 – 24 V DC /5 – 20 mA
Heat pump output 5 – 24 V DC /0.5 – 10 mA, current sink ≤ 100 mW
Valve outputs 24 V AC, 0.2 A average, 0.4 A peak
Power connection 1 m cable with europlug (except UK)
Connection terminals for power, pump, GPI and boiler Up to 4.0 mm² solid, or 2.5 mm² flexible with ferrules
Connection terminals for bus communication 0.5 mm² to 2.5 mm²
Connection terminals for valve outputs 0.2 mm² to 1.5 mm²
*) EN 60730-1 Automatic electrical controls for household and similar use
-- Part 1: General requirements
**) EN 60730-2-1 Automatic electrical controls for household and similar use
-- Part 2-1: Particular requirements for electrical controls for electrical
household appliances
***) EN 60730-2-9 Automatic electrical controls for household and similar use
-- Part 2-9: Particular requirements for temperature sensing controls
Usable in all Europe
Declaration of conformity:
We hereby declare under our own responsibility that products dealt
with by these instructions satisfy all essential demands linked to the
information stated in the Safety instruction booklet.
QUICK GUIDE
9
UPONOR SMATRIX BASE PRO · QUICK GUIDE
EN
CZ
DE
DK
EE
ES
FI
FR
HR
HU
IT
LT
LV
NL
NO
PL
PT
RO
RU
SE
SI
SK

Uponor Corporation
www.uponor.com
Uponor reserves the right to make changes, without prior notification,
to the specification of incorporated components in line with its policy
of continuous improvement and development.
1087356 10_2017_EN Production: Uponor AB, MRY, Virsbo; Sweden
Other manuals for Smatrix Base Pro
1
Table of contents
Other Uponor Controllers manuals

Uponor
Uponor Smatrix Base PRO X-148 User manual

Uponor
Uponor Smatrix Base PULSE User manual

Uponor
Uponor Smatrix Base PULSE User manual

Uponor
Uponor Smatrix Base Pro User manual

Uponor
Uponor Smatrix Wave X-165 Quick start guide

Uponor
Uponor Smatrix Base PULSE User manual

Uponor
Uponor Smatrix Base PRO Controller X-147 User manual

Uponor
Uponor A3041501 User manual

Uponor
Uponor KaMo Combi Port E User manual

Uponor
Uponor Smatrix Base PRO X-147 User manual